EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009G-410.A
An Eaton Brand
G
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Operation
When a higher pressure is
sensed at inlet 1 than at inlet 2
the ball within the cartridge is
forced against a seat opening
the higher pressure to outlet.
Description
This valve provides a means
of sensing the higher pres-
sures between two lines on
a hydraulic circuit allowing
this line to be used for an
auxiliary function such as the
removal of a mechanically
applied brake, the operation
of a gauge or to give a remote
pressure sensing line for the
control of a separate valve.
Ratings and Specifications
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F)
Typical application pressure (all ports) 240 bar (3500 psi) steel housing
Cartridge fatigue pressure (infinite life) 240 bar (3500 psi)
Rated flow 3 L/min (0.75 USgpm)
Internal leakage Between ports 2 and 1, and 2 and 3
<5 drops/min maximum @ 240 bar (3500 psi)
Cavity C-4-3
Temperature range -40°C to +120°C (-40° to + 248°F)
Fluids All general purpose hydraulic fluids such as
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration level Cleanliness code 18/16/13
Weight cartridge only 0,02 kg (0.044 lbs)
Seal kits 9900176-000 (Buna-N)
9900177-000 (Viton
®
)
Viton is a registered trademark of E. I. DuPont
Performance DataSectional View
When the higher pressure
appears at inlet 2 the ball is
forced against the other seat
which blocks inlet 1 and opens
up inlet 2 to outlet.
Features
Cartridge design enabling
speedy servicing when mount-
ed in a body or in a composite
manifold.
DSV2-4 - Shuttle Valve
Ball type
3 L/min (0.75 USgpm) • 240 bar (3500 psi)
Note: This valve is intended
for application as a load sense
shuttle valve in load sensing
systems
3
1
2
3
2
1