Typical Section
KTG4V-5
General Description
Vickers proportional valves shown in
this catalog are designed to provide a
controlled oil flow in proportion to a
command signal. They are available in
two types, firstly a double solenoid
version that will provide reversible flow
and return to an actuator, and
secondly a single solenoid version that
provides a single direction of flow.
Hydrostats are available for load
compensation and if flow
enhancement is required for the single
solenoid version, parallel flow path
modules are available that will boost
the flow capacity to nearly twice that of
the standard valve.
Additionally, both of these valve types
can be supplied with or without an
integral amplifier built directly onto the
valve.
KD/TG4V-5
This version is supplied without the
integral amplifier.
Features and Benefits
D Wide range of spool and flow rate
options
D Supported by amplifiers and
auxiliary function modules from the
Vickers range
D Electronic feedback LVDT ensures
accurate speed control
D Current feedback provides inherent
protection from electrical
interference
D Vibration and shock tested
KAD/TG4V-5KAD/TG4V-5
A range of proportional directional and
throttle valves with control amplifiers built
directly on, and prewired to, the valves.
Factory-set adjustments of gain, spool
deadband compensation, dither and
offset ensure high repeatability
valve-to-valve.
The only electrical inputs required are
power supply (24V) and a voltage
command signal of "10V. Electrical
connections are via a standard 7-pin
plug.
A monitor point allows the function of
the amplifier to be checked. Ramp
functions, if required, must be
generated externally.
Features and Benefits
D Factory-sealed adjustments
increase valve-to-valve accuracy
D Valve and amplifier selected,
ordered, delivered and installed as a
performance-tested package
D Standard 24V DC supply with wide
tolerance band
D Standard "10V DC command
signals
D Installation wiring reduced and
simplified
D Standard 7-pin connector
D LED status indication and monitor
point help troubleshooting
D Simple valve removal and
replacement for service
D Vibration and shock tested
D Supported by auxiliary function
modules
This product has been designed and tested to meet specific standards outlined in the European Electromagnetic
Compatibility Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and 93/68/EEC, article 5. For
instructions on installation requirements to achieve effective protection levels, see this leaflet, the Installation
Wiring Practices for Vickers Electronic Products leaflet 2468 and leaflet 02-123931A which is packed with every
KA valve. Wiring practices relevant to this Directive are indicated by Electromagnetic Compatibility (EMC).
GB–2452Rev. 10/97
VICKERS
®
Proportional Valves
K(A)D/TG4V-5, 3* Series
Proportional Directional Valves
Without Feed Back
PT BAL
Functional Symbols
7-pin
plug
Model Types KATG4V-5
PT BAL
7-pin
plug
Model Types KADG4V-5
PT BAL
Model Types KDG4V-5
Model Types KTG4V-5
PT BAL
Available Spools for K(A)DG4V-5
2C**N, meter-in/meter-out
2C65S, meter-out only
33C**N, meter-in/meter-out
Available Spools for K(A)TG4V-5
2B**N, meter-in/meter-out
Series type designator
A = Integral amplifier
Omit for non-integral amplifier
Control type
D = Directional valve
T = Throttle valve
Spool type
See “Functional Symbols” on previous
page
Flow rating and metering
∆p = 5 bar (72 psi) per metering flow
path, e.g. B to T
Spools for K(A)TG valves
2B30N = 30 L/min (7.9 USgpm)
2B50N = 50 L/min (13.2 USgpm)
2B70N = 70 L/min (18.5 USgpm)
Symmetric spools for K(A)DG valves
2C30N = 30 L/min (7.9 USgpm)
2C50N = 50 L/min (13.2 USgpm)
2C65S = 65 L/min (17.2 USgpm)
33C30N = 30 L/min (7.9 USgpm)
33C50N = 50 L/min (13.2 USgpm)
Asymmetric spools for K(A)DG valves
2C50N25 = 50 L/min (13.2 USgpm)
“A” port flow
25 L/min (6.6 USgpm)
“B” port flow
Model Code
1 2 3 4 5 6 7 8
1
2
3
Warning
To conform to the EC Electromagnetic Compatibility Directive (EMC) the valve with integral amplifiers must be fitted
with a metal 7-pin plug. The screen of the cable must be securely connected to the shell of the metal connector. A
suitable IP67 rated connector is available from Vickers, part no. 934939. This must be tightened with a torque of
2-2,5 Nm (1.5-2.0 lbf-ft) to achieve the IP67 rating. Alternatively a non IP67 rated connector is available from
ITT-Cannon, part no.CA 06 COM-E 14S A7 S.
The plastic plug, part number 694534, is only suitable for use in a sealed electromagnetic environment or outside of
the European Community.
Solenoid energization identity
V = Solenoid “A” is at port “A” end and
solenoid “B” at port “B” end,
independent of spool type
Blank = US ANSI B93.9 standard
requiring solenoid “A”
energization to connect P to A
and solenoid “B” to connect
P to B
Solenoid electrical connector
U = ISO 4400/DIN 43650,
non-integral amplifier type
only
F = Flying lead, integral
amplifier type only
Electrical connection
(KA valves only)
PD7 = 7-pin connector with
plastic plug
See warning note below
Port T limit code
6 = For 2C**S
spools
7 = For all other spools
Design number, 30 series
Subject to change. Installation
dimensions unaltered for design
numbers 30 to 39 inclusive.
Solenoid plugs
KD/TG4V valves only
To be ordered separately.
710775, for black plugs, marked B
710776, for gray plugs, marked A
4
5
6
7
8
Operating Data
Performance data is typical with fluid at 36 cSt (168 SUS) and 50_C (122_F) while using the basic Vickers power amplifier.
KD/TG4V-5 and KAD/TG4V-5 Valves
Relative duty factor Continuous rating (ED = 100%)
Type of protection, with electrical plugs fitted correctly IEC 144, Class IP65
Hysteresis, with flow through P-A-B-T,
∆p = 5 bar (72 psi) per metering path e.g. P-A
<8% of rated flow
Step input response, with flow through P-A-B-T,
∆p = 5 bar (72 psi) per metering path e.g. P-A
Required flow step:
0 to 100%
100% to 0
+90 to –90% (KADG4V-5 only)
Time to reach 90% of required step:
75 ms (0.075s)
50 ms (0.050s)
80 ms (0.080s)
Mass: KDG4V-5
KADG4V-5
KTG4V-5
KATG4V-5
6,8 kg (15.00 lb) approx.
7,2 kg (15.90 lb) approx.
5,3 kg (11.70 lb) approx.
5,7 kg (12.60 lb) approx.
KD/TG4V-5 Valves
Max. current, at 50_C (122_F) ambient:
Coil type G
Coil type GP
Coil type H
Coil type HA
3,5A
3,0A
1,6A
0,94A
Coil resistance, at 20_C (68_F):
Coil type G
Coil type GP
Coil type H
Coil type HA
1,68Ω
−
7,7Ω
23,5Ω
Coil inductance at 1000 Hz & 150 mV:
Coil type G
Coil type GP
Coil type H
Coil type HA
8 mH
–
38 mH
114 mH
Repeatability, valve-to-valve Optimized by adjustment of deadband, gain and ramp
potentiometers on associated Vickers amplifier
Supporting products:
Eurocard amplifier
Power supply
EEA-PAM-525-*-32
EEA-PSU-704-*-20
KAD/TG4V-5 Valves with Integral Amplifiers
Power supply
24V DC (21V to 36V including 10% peak-to-peak max. ripple)
max. current 3A
Command signal
Input impedance
0 to +10V DC, or 0 to –10V DC, or –10V to +10V DC
47 kΩ
7-pin plug connector
Pin connections: A
B
C
D
E
F
G
Power supply +ve
Power 0V
Signal 0V
+ve voltage command signal
–ve voltage command signal
Monitor output
Protective ground
Electro-magnetic compatibility (EMC):
Emission (10 v/m)
Immunity (10 v/m)
See “Warning” note regarding EMC on page 11.
EN 50081-2
EN 50082-2
Gain adjustment 25 to 125%
Zero adjustment "18%
Factory set adjustments Deadband, gain, dither and offset
Monitor point signal
Output impedance
0,5V per amp solenoid current
10 kΩ
Power stage PWM frequency 2 kHz nominal
Repeatability, valve-to-valve (at factory settings):
Flow gain at 100% command signal
v5%
Protection:
Electrical
Mechanical
Reverse polarity protected
IEC 144, Class IP65
Relative humidity 85 to 95% at 20 to 70_C (68 to 158_F)
Supporting products:
Auxiliary electronic modules (DIN-rail mounting):
EHA-CON-201-A-2* signal converter
EHD-DSG-201-A-1* command signal generator
EHA-RMP-201-A-2* ramp generator
EHA-PID-201-A-2* PID controller
Subplates, size 05
Mounting bolts
Note: If not using Vickers recommended bolt kits, bolts must
be to ISO 898 grade 12.9 or stronger.
This product has been designed and tested to meet specific standards outlined in the European
Electromagnetic Compatibility Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and
93/68/EEC, article 5. For instructions on installation requirements to achieve effective protection levels, see this
leaflet and the Installation Wiring Practices for Vickers Electronic Products leaflet 2468 and leaflet 02-123931A
which is packed with every KA valve.. Wiring practices relevant to this Directive are indicated by
Electromagnetic Compatibility (EMC).
Maximum Pressures, bar (psi)
Power Capacity Envelopes
Single Solenoid Models:
K(A)TG4V-5
Spool types as noted
Single Flow Path
P to B
0 20 40 60 L/min
0164 8 12 USgpm
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
Valve pressure drop
(A)
P
B
(T)
**B30N
**B50N
0 20 40 60 80 L/min
0205 10 15 USgpm
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
Valve pressure drop
A
P
B
T
**B30N
**B50N
Looped Flow Path
P to B plus A to T
Model
Port L condition s Ports P, A & B T Ls
K(A)DG4V-5-**C**N-Z-(V)M-U1-H7 Externally drained 315 (4567) 210 (3000) 10 (145)
All K(A)DG4V-5 models Blocked by mating surface 315 (4567) 160 (2320) 160 (2320)
K(A)TG4V-5 Externally drained
31 (4 6 )
210 (3000) 10 (145)
()
Blocked by mating surface
315 (4567)
160 (2320) 160 (2320)
s If port T pressure will not exceed 160 bar (2320 psi), port L need not be connected to tank.
Minimum Recommended Flow Rates
For spool types 2C and 33C
∆p = 10 bar (145 psi) for looped flow
PBT(PBT)
Valve size/spool code Min. flow rate:
L/min in
3
/min
()
P-A-B-T (or P-B-A-T).
K(A)DG4V-5-**C30N
1,5 91
K(A)DG4V-5-**C50N 2,5 152
K(A)DG4V-5-**C65S 3,0 182
0 20 40 60 80 L/min
0164 8 12 20 USgpm
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
Valve pressure drop
A
P
B
T
24
Max. system pressure =
max. pressure for port T: 210 bar (3000 psi)
90
**B50N
Double Solenoid Models:
K(A)DG4V-5
Spool types as noted
Single Flow Path
P to A, or P to B
A
P
(B)
(T)
(A)
P
B
(T)
or
A
P
B
T
or
A
P
B
T
0 20 40 60 L/min
0164 8 12 USgpm
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
Valve pressure drop
**C30N
**C50N
0 20 40 60 80 L/min
0205 10 15 USgpm
Flow rate
100
200
300
315
0
1000
2000
3000
4000
4500
psi bar
Valve pressure drop
**C30N
**C50N
90
2C65S
22
Looped Flow Path
P to A (or B) plus B (or A) to T
Single Solenoid Models:
K(A)TG4V-5
Parallel Flow Path
P to B and A to T using
parallel flow path module:
KDGMA-5-616877-10Rn or
KDGMA-5-02-139150-10Sn
1234510
0
–3
–6
20 30
135_
90_
45_
0
Frequency (Hz)
Frequency Response
–9
678
n See catalog 2336, “Subplates and Auxiliary
Connection Plates, Size 05”.
Single Flow Path
P to B
Spool types **B30N
Flow Gain
Single Solenoid Models, K(A)TG4V-5
Flow rate
USgpm L/min
70
60
30
0
0
10
20 40 60 80 100
Command signal (% of max.)
s
50
8
6
4
2
12
Flow rate
USgpm L/min
40
20
10
0
0
20 40 60 80 100
Command signal (% of max.)
s
30
80
14
16
2
50
4
6
8
10
12
(A)
P
B
(T)
A
P
B
T
Parallel Flow Paths
P to B and A to T using
parallel flow path module:
KDGMA-5-616877-10Rn or
KDGMA-5-02-139150-10Sn
Maximum system pressures for this configuration:
With “L” port externally drained 210 bar (3000 psi). . . .
With “L” port blocked 160 bar (2320 psi). . . . . . . . . . . . .
Spool types **B50N
40
10
20
18
20
22
Flow rate
USgpm L/min
40
20
10
0
0
20 40 60 80 100
Command signal (% of max.)
s
30
2
50
4
6
8
10
12
Spool types **B50N
14
16
60
s Curves shown are for spool types “2”. These points will vary from valve
to valve, but can be adjusted using the deadband compensation feature
of the drive amplifier.
For spool types “33” the curves are similar but flow starts at slightly
higher command signals.
Flow Gain
Double Solenoid Models, K(A)DG4V-5
Flow rate
USgpm L/min
40
20
10
0
0
20 40 60 80 100
Command signal (% of max.)
s
30
2
50
4
6
8
10
12
Spool types **C30N
Single Flow Path
P to A, or P to B
Flow rate
USgpm L/min
40
20
10
0
0
20 40 60 80 100
Command signal (% of max.)
s
30
2
50
4
6
8
10
12
Spool types **C50N
14
16
60
A
P
(B)
(T)
(A)
P
B
(T)
or
Flow rate
USgpm L/min
40
20
10
0
0
20 40 60 80 100
Command signal (% of max.)
s
30
2
50
4
6
8
10
12
Spool types **C30N
Looped Flow Paths
P to A (or B), plus B (or A) to T
Flow rate
USgpm L/min
40
20
10
0
0
20 40 60 80 100
Command signal (% of max.)
s
30
2
50
4
6
8
10
12
Spool types **C50N
14
16
60
A
P
B
T
or
A
P
B
T
Flow rate
USgpm L/min
40
20
10
0
0
20 40 60 80 100
Command signal (% of max.)
s
30
2
50
4
6
8
10
12
Spool type 2C65S
14
16
60
18
20
22
70
80
s Curves shown are for spool types “2”. These points will vary from valve to
valve, but can be adjusted using the deadband compensation feature of the
drive amplifier.
For spool types “33” the curves are similar but flow starts at slightly higher
command signals.
KADG4V-5 and KATG4V-5
Wiring
Connections must be made via the 7-pin
plug mounted on the amplifier.
Recommended cable sizes are:
Power cables:
For 24V supply
0,75 mm
2
(18 AWG) up to 20m (65 ft)
1,00 mm
2
(17 AWG) up to 40m (130 ft)
Signal cables:
0,50 mm
2
(20 AWG)
Screen:
A suitable cable would have 7 cores, a
separate screen for the signal wires and
an overall screen.
Electrical Block Diagram
Command Signals and Outputs
Gain
Modulator
+15V
Valve envelope
7-pin plug connections
+24V
A
Power 0V
Signal 0V
Protective ground
Solenoid drive 2
Deadband
Positive
Monitor output
Negative
Command
signal
voltage
(see table)
–15V
0V
Solenoid drive 1
B
C
F
D
E
G
Dither
7-pin plug
Flow
di i
Pin D Pin E
direction
Positive 0V P to A
0V Negative
U
D
- U
E
= Positive
Negative 0V P to B
0V Positive
U
D
- U
E
= Negative
Warning
All power must be switched
off before connecting or
disconnecting any plugs.
Typical Connection Arrangements
KADG4V-5 and KATG4V-5
Warning
Do not ground pin C. If the
local ground (pin C) is not used for
differential monitor electronics, do not use.
Read monitor pin F with respect to ground.
User panel
Outer
Screen
“KA” valve
A
B
F
G
D or E
E or D
CJ
+24V
0V
Demand
Signal
Solenoid
Current
Monitor
Power
Supply
Enclosure
Valve must
be connected
to ground via
subplate
0V
Input
+/– 10V
0V
Connector shell
J Solenoid current monitor voltage (pin F)
will be referenced to the KA valve local
ground. A “local ground” (pin C) is
provided for optional use by differential
input customer supplied electronics.
Wiring Connections for Valves with integral Amplifier
Y Note: In applications where the valve
must conform to European RFI/EMC
regulations, the outer screen (shield) must
be connected to the outer shell of the
7-pin connector and the valve body must
be fastened to the earth ground. Proper
earth grounding practices must be
observed in this case, as any differences
in command source and valve ground
potentials will result in a screen (shield)
ground loop.
Y
0V must be
connected
to ground
Warning
Electromagnetic Compatibility (EMC)
It is necessary to ensure that the valve is wired-up as above. For effective protection, the user
electrical cabinet, the valve subplate or manifold, and the cable screens should be connected to
efficient ground points. The metal 7-point connector, part no. 934939, should be used for the
integral amplifier.
In all cases, both valve and cable should be kept as far as possible from any sources of
electromagnetic radiation such as cables carrying heavy current, relays and certain kinds of
portable radio transmitters, etc. Difficult environments could mean that extra screening may b
necessary to avoid the interference.
It is important to connect the 0V lines as shown above. The multi-core cable should have at least
two screens to separate the demand signal and monitor output from the power lines.
Drain wire
Inner screen
Installation Dimensions in mm (in)
KTG4V-5
13 (0.51)
for plug
removal
8 (0.32)
for solenoid
removal
C
Fixing
bolt
70 (2.76)
max.
106
(4.18)
88
(3.47)
max.
76,5
(3.01)
max.
21,5 (0.85)
100,5 (3.96)
255 (10.04)
17 (0.67) for plain overrides
37 (1.46) for type H overrides
8 (0.32)
for solenoid removal
Port A
C
Port B
C
s
30
(1.18)
Bleed
screw
both ends
268 (10.55)
97 (3.82)
u
s Mounting surface, seals supplied.
For mating surface dimensions and subplate options, see catalog 2336.
For mounting bolt kit options see catalog 2314.
KDG4V-5
u Electrical plug connections (without indicator light) to ISO 4400/DIN 43650.
Must be separately ordered by part number(s).
Part No Color Solenoid coil Cable gland
710775 Black Solenoid B Pg. 11
710776 Gray Solenoid A Ø 6-10 (0.23-0.39 dia)
Solenoid and plug identities
At port “A” end At port “B” end For
A B KDG4V-5-*C***(-*)-VM
B A KDG4V-5-*C***(-*)-M
The cable entry can be repositioned at 90_ intervals form the position shown.
This is done by re-assembling the contact holder into the appropriate position
inside the plug connector housing.
13 (0.51)
for plug
removal
Solenoid bleed
screw
203 (8.0) max.
97 (3.82)
30 (1.18)
195 (7.66)
8 (0.32)
for solenoid
removal
17 (0.67) for plain
override
37 (1.46) for type
H override
100,5 (3.96)
21,5 (0.85)
106
(4.18)
88
(3.47)
max.
76,5
(3.01)
max.
Port A
C
Port B
C
70 (2.76)
max.
C
Fixing
bolt
u Electrical plug connections (without indicator light) to ISO 4400/DIN 43650.
Must be separately ordered by part number(s).
Part No Color Solenoid coil Cable gland For valve
710775 Black Solenoid B Pg. 11 KTG4V-5-*B***(-*)-M
710776 Gray Solenoid A Ø 6-10 (0.23-0.39 dia) KTG4V-5-*B***(-*)-VM
The cable entry can be repositioned at 90_ intervals from the position shown.
This is done by re-assembling the contact holder into the appropriate position
inside the plug connector housing.
u
4 holes thru Ø 7 (0.275), c’bored
Ø 11 (0.43) to depth shown
4 holes thru Ø 7 (0.275), c’bored
Ø 11 (0.43) to depth shown
3rd angle
projection
Installation Dimensions in mm (in)
KADG4V-5
KATG4V-5
217,0 (8.60)
227,0 (8.90)
167,4
(6.6)
max.
Do not
remove
these
plugs.
277,5 (10.9)
70,0
(2.76)
max.
167,4
(6.6) max.
40,0
(1.6)
227,0 (8.9)
25,0
(1.0)
Metal plug 934939
Cable outside diameter 8,0 to 10,5 (0.31 to 0.41) Must be used
for full EMC protection. See “Warning” note on page 11.
7-pin plug
Remove plug for
access to the gain
potentiometer
Plastic plug 694534
PG11. Cable maximum
outside diameter
11,0 (0.43)
See warning note on page 3 regarding the use of 7-pin plugs.
Hydraulic Fluids
Materials and seals used in these
valves are compatible with:
Anti-wear petroleum oils L-HM. . . . . . . .
Non-alkyl based
phosphate esters L-HFD. . . . . . . . . . . . .
The extreme operating range is 500 to
13 cSt (270 to 70 SUS) but the
recommended running range is 54 to
13 cSt (245 to 70 SUS). For further
technical information about fluids see
Technical Information leaflet B-920 or
I-286-S.
Contamination Control Requirements
Recommendations on contamination
control methods and the selection of
products to control fluid condition are
included in Vickers publication 9132 or
561, “Vickers Guide to Systemic
Contamination Control”. The book also
includes information on the Vickers
concept of “ProActive Maintenance”.
The following recommendations are
based on ISO cleanliness levels at
2 mm, 5 mm and 15 mm.
For products in this catalog the
recommended levels are:
Up to 210 bar (3050 bar) 18/16/13. . . . .
Above 210 bar (3050 bar) 17/15/12. . . .
Installation and Start-up Guidelines
The proportional valves in this catalog
can be mounted in any attitude but it
may be necessary, in certain demanding
applications, to ensure that the
solenoids are kept full of hydraulic fluid.
If this proves to be the case any
accumulated air can be bled from the
solenoid bleed screws. This task is
easier if the valve has been mounted
base downwards. Good installation
practice dictates that the tank port, and
any drain port, are piped so as to keep
the valve full of fluid once the system
start-up has been completed.
Temperatures
For petroleum oil:
Min. –20°C (–4°F). . . . . . . . . . . . . . . . . .
Max.* +70°C (158°F). . . . . . . . . . . . . . . .
*
To obtain optimum service life from both fluid and
hydraulic system, 65° C (150°F) normally is the
maximum temperature.
For other fluids where limits are outside
those of petroleum oil, consult fluid
manufacturer or Vickers representative.
Whatever the actual temperature range,
ensure that viscosities stay within those
specified under “Hydraulic Fluids”.
Ambient for:
Valves, including any feedback
transducers and integral amplifiers at full
performance specification: –20 to +60_C
(–4 to +140_F).
Valves, as above, will operate at
temperatures of 0 to –20_C (32 to –4_F)
but with a reduced dynamic response.
Storage:
–25 to +85_C (–13 to +185_F)
Eurocard electronics:
0 to 50_C (32 to 122_F)
Service Information
The products from this range are preset
at the factory for optimum performance,
disassembling critical items would
destroy those settings. It is therefore
recommended that should any
mechanical or electronic repair be
necessary they should be returned to the
nearest Vickers repair center. The
products will be refurbished as
necessary and retested to specification
before return to you.
Field repair is restricted to the
replacement of the listed parts below.
Seal kit (KD/TG) 565110. . . . . . . . . . . . .
Seal kit (KAD/TG) 02-139127. . . . . . . . .
Further Information