DGMX2 Pressure Reducing/Relieving Valves
General Description
These two-stage spool valves maintain
a reduced outlet pressure against
variations in inlet pressure.
These valves are able to act as relief
valves (at 50% of maximum flow) to
prevent excess pressure being
developed when an actuator is subject
to a reactive load. Relief flow is directed
to the “T
B
” port. Therefore, for the relief
function to operate, all components
above this DGMX2 module must contain
the “T
B
” port, and the directional valve
must have the “T
B
” bypass feature.
Pilot control may be from the “P”, “A”, or
“B” port. Pilot drain flow may be directed
internally to tank port “T
A
”, or externally
out of the valve body.
Any pressure in the line to which these
valves are drained is additive to the
valve pressure setting.
The valve pressure setting is adjustable
by means of either an adjusting screw
containing an internal hex, a
hand-adjust knob, or a micrometer knob
with keylock.
Different spring ratings cover an overall
pressure range from 2 to 315 bar
(30-4500 psi).
The metering spool element in this
design is always positioned in the “P”
line (see symbols on page14). The
connection of the pilot control line
determines at which port the reduced
pressure is obtained. For example:
“PP” pilot for reduced pressure
in “P” port
“PA” pilot for reduced pressure
in “A” port
“PB” pilot for reduced pressure
in “B” port
The “A” and “B” line models provide for
reduced pressure when “P” is connected
to “A” or “B”. It allows free flow through
the service port when connected to “T”
(all via a four-way directional valve).
3 45 87691 2
Model Code
1
2
Valve function
Manifold or subplate mounted
reducing/relieving valve.
Interface
5 - ISO 4401-AC-05-4-A, CETOP 5
RP35A size 5 ANSI/NFPA D05
5N - NFPA D05 (Alt. A)
5P - NFPA D05 (Alt. B)
Port operated upon
P -Pressure port
Pilot control
A - Cylinder port A
B - Cylinder port B
P - Pressure port
3
5
6
7
Pressure range
A - 2,0 to 50 bar (30 to 725 psi)
B - 8,5 to 100 bar (125 to 1450 psi)
F - 8,5 to 200 bar (125 to 2900 psi)
G - 8,5 to 315 bar (125 to 4500 psi)
Adjustment device
H - Knob adjuster
K - Micrometer knob with keylock
W - Screw with locknut
External drain
E - External drain
Omit for internal drain models.
Remote control
Omit if not required.
Gage port & thread type
Gage port (all models),
external drain (E)
B -G
1
/
8
” (
1
/
8
” BSPF)
S -SAE-4 O-ring boss port
(0.4375-20 UNF-2B thread)
Design mumber - 30 series
Subject to change. Installation
dimensions unaltered for design
numbers 30 to 39 inclusive.
10
9
4
10
8