Hydrokraft Open Loop Piston Pumps
Technical Catalog
PVX
2
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Code
Form Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Basic Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
No Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DF Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DQ Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LR Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ES Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
HG Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
FE Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SP Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Special Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Combination Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Examples for Combination units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Pump Specifications
US . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Metric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Performance Curves
Performance Curves, Outlet Flow & Inlet Power, Shaft Input Power, 066 to 250 Series . . . . . . . . . 21
Operating Data: Theoretical Bearing Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Operating Data: Typical Drain Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Controls
DF, LR Pressure Compensator/Power Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
DQ Mooring Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
FE, HG Manual Displacement Adj. Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Electric Motor Displacement Control ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Pressure Signal Displacement Control DP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Proportional Valve Displacement Control SP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Table of Contents
(cont.)
Pump Dimensions *
PFXS 066. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
PFXS 090. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
PFXS 130. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
PFXS 180. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
PFXS 250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
PVXS 066 - 250 DF, Two Stage Pilot Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
PVXS 066 - 250 DF, with Load Sensing Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
PVXS 066 - 250 LR, with Pressure Limiter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
PVXS 066 - 250 ES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
PVXS 066 - 250 DP, with Prop. Pilot Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
PVXS 066 - 250 SP, with Prop. Pilot Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Thru - drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Splined Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
SAE4 - Bolt Mounting, Installation Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Application Data
Fluid Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
* Dimensions - PVXS-066 to 250 DQ/HG/FE ask for special drawings.
4
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Introduction
•
Axial piston pumps
with swashplate
design for reliable
operation and long life.
•
Pressure up to 420
bar. Rated speed up
to 1800 min
-1
. Higher
speeds possible.
•
Oversize shafts and
bearings.
•
Rotating and pressure
loaded parts are
pressure balanced.
•
Integrated pilot pump,
filter and pressure
relief valves available.
•
"Building block" design
gives these pumps a
wide range of
application.
•
Fast response times.
Displacement controls:
ES - Electric motor
displacement control
HG - Handwheel
displacement control
(Special feature)
FE - Screw adjustment
control (Special feature)
DF - Pressure
compensator controlled
DQ - Mooring control
LR - Power control with
pressure limiter
SP, SM - Displacement
proportional to electric
signal
DP - Displacement
proportional to pressure
signal
Dimensional information listed in this catalog is subject to change without notice.
Swash
Plate
Piston Shaft
Housing
Cylinder
Block
Valve
Plate
Control
Piston
Typical Section of Open Loop PVX Pump
AVAILABLE DISPLACEMENT
SIZES
66 ccm
90 ccm
130 ccm
180 ccm
AVAILABLE REPLACEMENT
UNIT DISPLACEMENT SIZES
250 ccm
5
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Fixed & Variable
Displacement Pumps
"X" Series
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
M XP
–
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
1
1 0
SV A
24 25 26 27 28 29 30
Form Page
The following 48-digit coding system has been
developed to identify all of the configuration options
for the "X" series (Open Loop) fixed and variable
displacement pumps. Use this model code to
specify a unit with the desired features. All 48-digits
must be present when ordering. You may want to
photocopy the matrix below to ensure that each
number is entered in the correct box. If adjustments
other than the standard setting (character 40 ... 43)
or special features (character 44 ... 48) are needed,
please provide the information when ordering.
Some characters are already filled out on the
following pages. For such characters there is
no option available.
Explanation for each character can be found
as follows:
CHARACTER PAGE
Basic Pump Model Code 1...23 6
Control Options 24...39 7 - 15
Customer Adjustment Specification 40...43 7 - 15
Special Features 44...46 16
Design Number 47...48 16
SPECIFY NON STANDARD ADJUSTMENT BELOW
SPECIFY SPECIAL FEATURE BELOW
6
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
P * X * — * * * M * * * * * * 1 * * * S V * A #
Model Code
Open Loop Pumps
“X" Series - Basic Pump
Pump
P – Open Loop Pumps
Displacement
F – Fixed
V – Variable
Pump Series
X – “X” Series
(was 20 design)
Configuration
S – Single Unit
R – Rear Unit
Separator
Displacement
cm
3
/r
066 – 66 cm
3
/r [4.0 in
3
/rev]
090 – 90 cm
3
/r [5.5 in
3
/rev]
130 –130 cm
3
/r [7.9 in
3
/rev]
180 –180 cm
3
/r [11.0 in
3
/rev]
250 – 250 cm
3
/r [15.3 in
3
/rev]
??? – Non-Standard
Displacement (PFX
Only)
Basic Standard
M – Metric
Mounting Flange
02 – ISO 3019/2-125A2HW
04 – ISO 3019/2-160A2HW
06 – ISO 3019/2-200A2HW
* See Chart Below
Rotation Direction
R – Right Hand [CW]
L – Left Hand [CCW]
** See Chart Below
Adjustment Stops
0 – No Stop
4 – Mechanical Adjustment
Stop Side A
(PVX only)
5 – Mechanical Adjustment
Stop Side B
(PVX only)
6 – Mechanical Adjustment
Stops Side A and B
(PVX only)
NOTE:
4 is used as max.
Adjustment on Side A.
5 is used as min.
Adjustment stop side A.
6 is the combination of
4 and 5 together
Thru-Drive Options
00 – None
0A – SAE A
0B – SAE B
0C – SAE C
0P – Pilot pump (8cm
3
/r)
(PVX only)
*** See Chart Below
Main Ports
1 – SAE ports - metric bolts
Main Port Orientation
A – Axial (in-line rear)
R – Radial (side ports)
Main Drive Shaft
End
01 – ISO straight key
02 – ISO spline
Drive Shaft Seal
Configuration
S – Single shaft seal
Seal Material
V – Viton**
Yo ke Position Indicator
0 – No position indicator
V – Visual position indicator
P– Position sensor
M – Sensor w/visual indicator
Surface Finish
A – Blue painted
Add Control Model
Code
Code (characters 24...43) on
the following pages
24
23
22
21
20
1918
17
16
1514
13
12
1110
9
876
5
4
3
2
1
2 3 4
5 186 7 8
9
10 11 12
13 14 15 16
17
19 20
21
22 23
1
24
*MOUNTING FLANGE OPTIONS AVAILABLE 066 090 130 180 250
ISO 3019/2-125A2HW • •
ISO 3019/2-160A2HW • •
ISO 3019/2-200A2HW •
**ROTATION DIRECTION 066 090 130 180 250
Right Hand •••••
Left Hand ••••
***THRU-DRIVE OPTIONS 066 090 130 180 250
SAE A •••••
SAE B • • •
7
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Control Type
00 – No Control
(For PFX only)
Displacement
Adjustment Options
0 – Not Applicable
Electronic Controls
00 – Not Required
Yo ke Displacement Zone
A – Single Side of Center “A”
Extra Functions
0 – Not Required
Pressure Control
Options
0 – Not Applicable
Power Control
000 – Not Applicable)
Pilot Oil Filter
0 – Not Applicable
Venting Valve
0 – Not Applicable
No Position Monitoring
0 – No Position Monitoring
Electric Motor Type
0 – No Electric Motor
Control Voltage
0 – Not Applicable
Customer
Adjustment Specifications
0000 – None
Special Features
Add special feature
description (characters
44...46) on page 16 if
required.
44
43424140
39
38
37
36
35
343332
31
30
29
2827
26
2524
25 26 27
0 0 0 0 0 A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #
28 4129 30 31
32
33 34 35
36 37 38 39
40
42 43
44
24
Model Code
Open Loop Pumps
“X" Series - No Control
8
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Control Type
DF – Pressure Compensator
Displacement
Adjustment Options
0 – Not Applicable
Electronic Controls
00 – Not Required
Yo ke Displacement Zone
A – Single Side of Center “A”
Extra Functions
0 – Not Required
1 – Load Sensing Extra
Function
Pressure Control
Options
0 – Not Applicable
F –Remote Port Only
K –Electro Proportional
Relief Valve-
Incl. Electr. Card
Power Control
000 – Not Applicable
Pilot Oil Filter
0 – Not Applicable
Venting Valve
0 – Not Applicable
1 – With Solenoid Valve
Position Monitoring
0 – No Position Monitoring
Electric Motor Type
0 – No Electric Motor
Control Voltage of
Venting Valve
0 – Not Applicable
B – 110 AC 50 HZ/
120 AC 60 HZ
D – 220 AC 50 HZ/
240 AC 60 HZ
G – 12 VDC
J – 24 VDC
Customer
Adjustment Specification
0000 – None
???? – Yes (final number will
be assigned by Eaton.
Specify on table
below)
Special Features
Add special feature
description (characters
44...46) on page 16 if
required.
44
43424140
39
38
37
36
35
343332
31
30
29
2827
26
2524
Model Code
Open Loop Pumps
“X" Series - DF Control
25 26 27
D F 0 0 0 A * * 0 0 0 0 * 0 0 * * * * * #
28 4129 30 31
32
33 34 35
36 37 38 39
40
42 43
44
24
*CUSTOMER ADJUSTMENT SPECIFICATIONS
Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
-
Mech. Stop Side A L/min Q
max
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Q
min
(used as min Adjustment Stop Side B)
Pressure Control Main Stage bar 20
-
Pressure Control Pilot Valve bar 19
Load Sense p bar 15 <15 bar not possible
9
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
*CUSTOMER ADJUSTMENT SPECIFICATIONS
Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
-
Mech. Stop Side A L/min Q
max
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Q
min
(used as min Adjustment Stop Side B)
Pressure Control Main Stage bar 20
-
Pressure Control Pilot Valve bar 90
Control Type
DQ – Mooring Control
Displacement
Adjustment Options
0 – Not Applicable
Electronic Controls
00 – Not Required
Yo ke Displacement Zone
C – Over Center
Extra Functions
0 – Not Required
Pressure Control
Options
0 – Not Applicable
F – Remote Port Only
K – Electro Proportional
Relief Valve–
Incl. Electr. Card
Power Control
000 – Not Applicable
Pilot Oil Filter
0 – Not Applicable
Venting Valve
0 – Not Applicable
1 – With Solenoid Valve
Position Monitoring
0 – No Position Monitoring
Electric Motor Type
0 – No Electric Motor
Control Voltage of
Venting Valve
0 – Not Applicable
B – 110 AC 50 HZ/
120 AC 60 HZ
D – 220 AC 50 HZ/
240 AC 60 HZ
G – 12 VDC
J – 24 VDC
Customer
Adjustment Specification
0000 – None
???? – Yes (final number will
be assigned by Eaton.
Specify on table
below)
Special Features
Add special feature
description (characters
44...46) on page 16 if
required.
44
43424140
39
38
37
36
35
343332
31
30
29
2827
26
2524
Model Code
Open Loop Pumps
“X" Series - DQ Control
25 26 27
D Q 0 0 0 C 0 * 0 0 0 0 * 0 0 * * * * * #
28 4129 30 31
32
33 34 35
36 37 38 39
40
42 43
44
24
MOORING CONTROL AVAILABLE ON THE FOLLOWING FRAMES
Available Not Available
066 *
090 *
130 *
180 *
250 *
10
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Control Type
LR – Power Control
Displacement
Adjustment Options
0 – Not Applicable
Electronic Controls
00 – Not Required
Yo ke Displacement Zone
A – Single Side of Center “A”
Extra Functions
2 – Pressure Limiter Extra
Function
3 – Load Sense & Pressure
Limiter Extra Function
Pressure Contro
Options
0 – Not Applicable
F –Remote Port Only
K –Electro Proportional
Relief Valve–
Incl. Electr. Card
Power Control
??? – KW at 1500 rpm
Pilot Oil Filter
0 – Not Applicable
Venting Valve
0 – Not Applicable
1 – With Solenoid Valve
Position Monitoring
0 – No Position Monitoring
Electric Motor Type
0 – No Electric Motor
Control Voltage of
Venting Valve
0 – Not Applicable
B – 110 AC 50 HZ/
120 AC 60 HZ
D – 220 AC 50 HZ/
240 AC 60 HZ
G – 12 VDC
H – 24 VDC
Customer
Adjustment Specification
0000 – None
???? – Yes (final number will
be assigned by Eaton.
Specify on table
below)
Special Features
Add special feature
description (characters
44...46) on page 16 if
required.
44
434241
39
38
37
36
35
343332
31
30
29
2827
26
2524
Model Code
Open Loop Pumps
“X" Series - LR Control
25 26 27
L R 0 0 0 A * * * * * 0 * 0 0 * * * * * #
28 4129 30 31
32
33 34 35
36 37 38 39
40
42 43
44
24
*CUSTOMER ADJUSTMENT SPECIFICATIONS
Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
Mech. Stop Side A L/min Q
max
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Q
min
(used as min Adjustment Stop Side B)
Pressure Control Main Stage bar 20
Pressure Control Pilot Valve bar 90
Load Sense p bar 15 <15 bar not possible
11
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Control Type
ES – Electric Motor
Displacement
Displacement
Adjustment Options
M – Electric Motor -
Fast Response*
N – Electric Motor -
Medium Response*
P – Electric Motor -
Slow Response*
Electronic Controls
00 – Not Required
Yo ke Displacement Zone
A – Single Side of Center “A”
Extra Functions
0 – Not Required
Pressure Control
Options
0 – Not Applicable
Power Control
000 – Not Applicable
Pilot Oil Filter
0 – Not Applicable
Venting Valve
0 – Not Applicable
Position Monitoring
A –4 Limit Switches
B –8 Limit Switches
P –4 Limit Switches
w/Sensor
T –8 Limit Switches
w/Sensor
Electric Motor Type
2 – Motor With Brake (IP-54)
3 – Motor Without Brake
(Explosion Proof)
Control Voltage of
Venting Valve
0 – Not Applicable
Customer
Adjustment Specification
0000 – None
???? – Yes (final number will
be assigned by Eaton.
Specify on table
below)
Special Features
Add special feature
description (characters
44...46) on page 16 if
required.
44
43424140
39
38
37
36
35
343332
31
30
29
2827
26
2524
Model Code
Open Loop Pumps
“X" Series - ES Control
25 26 27
E S * 0 0 A 0 * 0 0 0 0 0 * * 0 * * * * #
28 4129 30 31
32
33 34 35
36 37 38 39
40
42 43
44
24
**CUSTOMER ADJUSTMENT SPECIFICATIONS
Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
Mech. Stop Side A L/min Q
max
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Q
min
(used as min Adjustment Stop Side B)
Displacement Adjusted to… cm
3
/rev. ~50% Q
max
Position Monitoring Switch 1 L/min 0
2 L/min 95% of Q
max
<95% not possible
3 L/min
4 L/min
5 L/min
6 L/min
7 L/min
8 L/min
Response Time (sec) for Zero to max. Displacement
SIZE 066/090 130/180 250
Frequency 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Fast 7 6 18 15 15 13
Medium 24 20 35 29 30 25
Slow 38 32 54 45 48 40
12
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Control Type
HG – Handwheel
Displacement Control
Displacement
Adjustment Options
0 – Not Applicable
Electronic Controls
00 – Not Required
Yo ke Displacement Zone
A – Single Side of Center “A”
Extra Functions
0 – Not Required
Pressure Control
Options
0 – Not Applicable
Power Control
000 – Not Applicable
Pilot Oil Filter
0 – Not Applicable
Venting Valve
0 – Not Applicable
Position Monitoring
0 – No Position Monitoring
Electric Motor Type
0 – No Electric Motor
Control Voltage of
Venting Valve
0 – Not Applicable
Customer
Adjustment Specification
0000 – None
???? – Yes (final number will
be assigned by Eaton.
Specify on table
below)
Special Features
Add special feature
description (characters
44...46) on page 16 if
required.
44
43424140
39
38
37
36
35
343332
31
30
29
2827
26
2524
Model Code
Open Loop Pumps
“X" Series - HG Control
25 26 27
H G 0 0 0 A 0 0 0 0 0 0 0 0 0 0 * * * * #
28 4129 30 31
32
33 34 35
36 37 38 39
40
42 43
44
24
*CUSTOMER ADJUSTMENT SPECIFICATIONS
Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
Displacement Adjusted to... L/min Q
max
13
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Control Type
FE – Screw Adjustment
Displacement Control
Displacement
Adjustment Options
0 – Not Applicable
Electronic Controls
00 – Not Required
Yo ke Displacement Zone
A – Single Side of Center “A”
Extra Functions
0 – Load Sensing
Extra Function
Pressure Control
Options
0 – Not Applicable
Power Control
000 – Not Applicable
Pilot Oil Filter
0 – Not Applicable
Venting Valve
0 – Not Applicable
Position Monitoring
0 – No Position Monitoring
Electric Motor Type
0 – No Electric Motor
Control Voltage of
Venting Valve
0 – Not Applicable
Customer
Adjustment Specification
0000 – None
???? – Yes (final number will
be assigned by Eaton.
Specify on table
below)
Special Features
Add special feature
description (characters
44...46) on page 16 if
required.
44
434241
39
38
37
36
35
343332
31
30
29
2827
26
2524
Model Code
Open Loop Pumps
“X" Series - FE Control
25 26 27
F E 0 0 0 A 0 0 0 0 0 0 0 0 0 0 * * * * #
28 4129 30 31
32
33 34 35
36 37 38 39
40
42 43
44
24
*CUSTOMER ADJUSTMENT SPECIFICATIONS
Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
Displacement Adjusted to... L/min Q
max
14
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Control Type
DP – Pressure Signal
Adjustment
Displacement Control
Displacement
Adjustment Options
G – Mounting Interface
CETOP 3 Only
H – Remote Port G 1/4
J – Proportional Relief Inc.
Electronics
Electronic Controls
00 – Not Required
Yo ke Displacement Zone
A – Single Side of Center “A”
Extra Functions
0 – Not Required
Pressure Control
Options
0 – Not Applicable
Power Control
000 – Not Applicable
Pilot Oil Filter
0 – Not Applicable
V – Filter with Visual
Indicator
E – Filter with Electrical
Indicator
Venting Valve
0 – Not Applicable
Position Monitoring
0 – No Position Monitoring
Electric Motor Type
0 – No Electric Motor
Control Voltage of
Venting Valve
0 – Not Applicable
Customer
Adjustment Specification
0000 – None
???? – Yes (final number will
be assigned by Eaton.
Specify on table
below)
Special Features
Add special feature
description (characters
44...46) on page 16 if
required.
44
43424140
39
38
37
36
35
343332
31
30
29
2827
26
2524
Model Code
Open Loop Pumps
“X" Series - DP Control
25 26 27
D P * 0 0 A 0 0 0 0 0 * 0 0 0 0 * * * * #
28 4129 30 31
32
33 34 35
36 37 38 39
40
42 43
44
24
*CUSTOMER ADJUSTMENT SPECIFICATIONS
Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
-
Pilot Pressure bar 60
Mech. Stop Side A L/min Q
max
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Q
min
(used as min Adjustment Stop Side B)
15
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Control Type
SP – Proportional Valve
Adjustment
Displacement Control
Displacement
Adjustment Options
C – With CETOP 3 Prop Valve
KDG4V 3
F – With CETOP 5 Prop Valve
Electronic Controls
03 – ER 9.3 - 10 (CETOP 3)
04 – ER 9.4 - 10 (CETOP 5)
Yo ke Displacement Zone
A – Single Side of Center “A”
Extra Functions
0 – Not Required
Pressure Control
Options
0 – Not Applicable
Power Control
000 – Not Applicable
Pilot Oil Filter
V –Filter with Visual Indicator
E – Filter with Electrical
Indicator
Venting Valve
0 – Not Applicable
Position Monitoring
0 – No Position Monitoring
Electric Motor Type
0 – No Electric Motor
Control Voltage of
Venting Valve
0 – Not Applicable
Customer
Adjustment Specification
0000 – None
???? – Yes (final number will
be assigned by Eaton.
Specify on table
below)
Special Features
Add special feature
description (characters
44...46) on page 16 if
required.
44
43424140
39
38
37
36
35
343332
31
30
29
2827
26
2524
Model Code
Open Loop Pumps
“X" Series - SP Control
25 26 27
S P * * * A 0 0 0 0 0 * 0 0 0 0 * * * * #
28 4129 30 31
32
33 34 35
36 37 38 39
40
42 43
44
24
*CUSTOMER ADJUSTMENT SPECIFICATIONS
Standard Customer Specified
Unit Adjustment Adjustment Remarks
All Revolution Adjustments below set at .. rpm 1500
-
Pilot Pressure bar 60 -
Mech. Stop Side A L/min Q
max
(used as max Adjustment Stop Side A)
Mech. Stop Side B L/min Q
min
(used as min Adjustment Stop Side B)
Max. Stop by Control Side A L/min 95% Q
max
EI Card Adjustment Refer to EI card Manual
done by customer
Min. Stop by Control Side A L/min 0+/-2.5% EI Card Adjustment Refer to EI card Manual
done by customer
Ramp Time 0 A For 100% Stroke sec 0 EI Card Adjustment Refer to EI card Manual
done by customer
Ramp Time A 0 For 100% Stroke sec 0 EI Card Adjustment Refer to EI card Manual
done by customer
Preset Input Signals S1....S4 L/min - EI Card Adjustment Refer to EI card Manual
done by customer
16
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Open Loop Pumps
“X" Series - Special Features
* * * 1 0
Special Features
000 – None
*** – Defined by Eaton
Design Number
10 – Design Number
4847
464544
44 45 46 47 48
17
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Combination Unit
P – Pump
T – Transmission Pump
M – Motor
Displacement
F – Filled
V – Variable
Pump Series
W – “W” Series
(was 30 design)
X – “X” Series
(was 20 design)
Combination Unit
C
Separator
First
Displacement cm
3
/r
066 – 66 cm
3
/r [4.0 in
3
/rev]
090 – 90 cm
3
/r [5.5 in
3
/rev]
130 –130 cm
3
/r [7.9 in
3
/rev]
180 –180 cm
3
/r [11.0 in
3
/rev]
250 – 250 cm
3
/r [15.3 in
3
/rev]
360 – 360 cm
3
/r [22.0 in
3
/rev]
500 –500 cm
3
/r [30.5 in
3
/rev]
750 – 750 cm
3
/r [45.8 in
3
/rev]
First Control Type
00 – No Control (for Fixed
Displacement Only)
DF –Pressure Compensator
LR –Power Control
ES – Electric Motor Control
HG – Handwheel
Displacement Control
FE – Screw Adjustment
Displacement Control
SM – Servo Adjustment
Displacement Control -
Mech Feedback
DP –Pressure Signal
Displacement Control
SP –Proportional Valve
Displacement Control
Second
Displacement cm
3
/r
066 – 66 cm
3
/r [4.0 in
3
/rev]
090 – 90 cm
3
/r [5.5 in
3
/rev]
130 –130 cm
3
/r [7.9 in
3
/rev]
180 –180 cm
3
/r [11.0 in
3
/rev]
250 – 250 cm
3
/r [15.3 in
3
/rev]
360 – 360 cm
3
/r [22.0 in
3
/rev]
500 –500 cm
3
/r [30.5 in
3
/rev]
750 – 750 cm
3
/r [45.8 in
3
/rev]
Second Control Type
00 –No Control (for Fixed
Displacement Only)
DF –Pressure Compensator
LR –Power Control
ES – Electric Motor Control
HG – Handwheel
Displacement Control
FE – Screw Adjustment
Displacement Control
SM – Servo Adjustment
Displacement Control -
Mech Feedback
DP –Pressure Signal
Displacement Control
SP –Proportional Valve
Displacement Control
Third
Displacement cm
3
/r
000 – Not Required
066 – 66 cm
3
/r [4.0 in
3
/rev]
090 – 90 cm
3
/r [5.5 in
3
/rev]
130 –130 cm
3
/r [7.9 in
3
/rev]
180 –180 cm
3
/r [11.0 in
3
/rev]
250 – 250 cm
3
/r [15.3 in
3
/rev]
360 – 360 cm
3
/r [22.0 in
3
/rev]
500 –500 cm
3
/r [30.5 in
3
/rev]
750 – 750 cm
3
/r [45.8 in
3
/rev]
Third Control Type
00 –No Control (for Fixed
Displacement Only)
DF –Pressure Compensator
LR –Power Control
ES – Electric Motor Control
HG – Handwheel
Displacement Control
FE – Screw Adjustment
Displacement Control
SM – Servo Adjustment
Displacement Control -
Mech Feedback
DP –Pressure Signal
Displacement Control
SP –Proportional Valve
Displacement Control
Fourth
Displacement cm
3
/r
000 – Not Required
066 – 66 cm
3
/r [4.0 in
3
/rev]
090 – 90 cm
3
/r [5.5 in
3
/rev]
130 –130 cm
3
/r [7.9 in
3
/rev]
180 –180 cm
3
/r [11.0 in
3
/rev]
250 – 250 cm
3
/r [15.3 in
3
/rev]
360 – 360 cm
3
/r [22.0 in
3
/rev]
500 –500 cm
3
/r [30.5 in
3
/rev]
750 – 750 cm
3
/r [45.8 in
3
/rev]
Fourth Control Type
00 –No Control (for Fixed
Displacement Only)
DF –Pressure Compensator
LR –Power Control
ES – Electric Motor Control
HG – Handwheel
Displacement Control
FE – Screw Adjustment
Displacement Control
SM – Servo Adjustment
Displacement Control -
Mech Feedback
DP –Pressure Signal
Displacement Control
SP –Proportional Valve
Displacement Control
Assembly
Numbers
HC81 – Defined By Eaton
Assembly Numbers
Defined By Eaton
39383736353433323130
29282726
2524
232221
2019
18 17 16
1514
131211
109
8 7 6
5
4
3
2
1
Model Code
Combination Units
•
For a combination of
two or more units fill
out this Combination
Model Code.
•
Start with the biggest
size unit for the first
displacement.
•
For each unit included
in this combination, a
separate model code
must be chosen. Use
the form on page 4.
•
Character 26 to 39 will
be P/N of the
combination. This
number will be defined
by Eaton and provided
in the order
acknowledgement.
•
Charge and Pilot Pump
through drive option
must be specified on
the rear unit of the
combination (as a
special feature).
•
Front and middle units
shall have the through
drive option of the
following unit in the
combination.
2 3 4
* * * C — * * * * * * * * * * * * * * * * * * * *
1
5 186 7 8
9
10 11 12
13 14 15 16
17
26
19 20
21
22 23 24
25
27
28 29 30 31
32
33 34 35
36 37 38 39
H C 8 1 * * * * * * * * * *
18
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Model Code
Examples for
Combination Units
Example 1: Combination
of two open loop pumps
Model Code Front Unit PVWF-500M08R0001R02SVMASPC03A0000000000000000010
Model Code Rear Unit PVXR-250M07R0001R02SVMASPC03A0000000000000000010
Model Code Combination Unit PVWC-500SP250SP0000000000HC81**********
Example 2: Combination
of one closed loop - and
two open loop pumps
(For other product
model codes refer to the
according catalog)
Mode Code Front Unit TVWF-500M08R0000H1R02SVMA20SPC03C00000000E000H000000010
Model Code Middle Unit PVWM-250M07R0001R02SV0ADF000A0000000000000000010
Model Code Rear Unit PFXR-130M02R00P1A02SV0A00000A0000000000000000010
Model Code Combination Unit TVWC-500SP250DF1300000000HC81**********
19
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Specifications -
US
MODEL 66 90 130 180 250
Design Swashplate - Axial piston pump
Type of mounting Flange or foot-mounted. tandem is foot mounted only
Pipe connection SAE Flange B psi 1 1/2" = 3000 2" = 3000 2 1/2" = 3000 2 1/2" = 3000 3 1/2" = 500
A 1" = 6000 1" = 6000 1" = 6000 1 1/4" = 6000 1 1/4" = 6000
Direction of rotation Clockwise when viewing shaft end of pump
Counterclockwise available on request
Speed range n
min rpm 150
nmax 1800
Installation position Optional, see mounting information
Ambient temperature range min °F -4
max 122
Weight m lb 121 165 234 251 467
Mass of inertia J lb ft
2
0.38 0.38 1.068 1.068 3.465
HYDRAULIC CHARACTERISTICS
Nominal pressure (100% duty cycle) p
N psi 5000
Input pressure p
1min psi 12.5 abs
p1max psi 725
Maximum pressure to DIN 24312 p
2max psi 6090
Hydraulic fluid Hydraulic oil to DIN 51524 part 2. Refer to section Application Data-Fluid Recommendations
Hydraulic fluid temperature range min °F -13 (on startup)
max 194
Viscosity range for continuous operation min cSt 10
max cSt 75
Maximum permissible start viscosity max cSt 1000
Filtering ISO 4406 18/15/13
Maximum geometric n= 1500 rpm V
g in
3
4.1 5.5 7.9 11.0 15.2
displacement n= 1800 rpm
Maximum geometric n= 1500 rpm Q
g USgpm 26 36 52 71 99
pump flow n= 1800 rpm 32 43 62 86 119
Case pressure pv max psi max. 7.2psi over p1. p
max
= 58 abs.
DRIVE
Maximum driving torque - single unit M1 Single lb.ft. 325 444 640 887 1233
(p
2 max.
, = 100%)
Maximum power consumption - single unit P
1 Single hp 93 126 182 254 355
(p
2 max.
, = 100%; n= 1800 rpm)
Maximum driving torque limited to M
1 Comb. lb.ft. 2x325 2x444 2x640 2x887 2x1233
splined shaft only - comb. unit
20
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Specifications -
Metric
MODEL 66 90 130 180 250
Design Swashplate - Axial piston pump
Type of mounting Flange or foot-mounted. tandem is foot mounted only
Pipe connection SAE/Flange B psi 1 1/2" = 3000 2" = 3000 2 1/2" = 3000 2 1/2" = 3000 3 1/2" = 500
A 1" = 6000 1" = 6000 1" = 6000 1 1/4" = 6000 1 1/4" = 6000
Direction of rotation Clockwise when viewing shaft end of pump
Counterclockwise available on request
Speed range n
min min
-1
150
nmax 1800
Installation position Optional, see mounting information
Ambient temperature range min °C -20
max 50
Weight m kg 55 75 106 114 212
Mass of inertia J kg m
2
0.016 0.016 0.045 0.045 0.146
HYDRAULIC CHARACTERISTICS
Nominal pressure (100% duty cycle) p
N bar 350
Input pressure p
1min bar 0.85 abs
p1max bar 50
Maximum pressure to DIN 24312 p
2max bar 420
Hydraulic fluid Hydraulic oil to DIN 51524 part 2. Refer to section Application Data-Fluid Recommendations
Hydraulic fluid temperature range min °C -25 (on start up)
max 90
Viscosity range for continuous operation min cSt 10
max cSt 75
Maximum permissible start viscosity max cSt 1000
Filtering ISO 4406 18/15/13
Maximum geometric n= 1500 min
-1
Vg cm
3
66 90 130 180 250
displacement n= 1800 min
-1
Maximum geom. n= 1500 min
-1
Qg L/min 99 135 195 270 375
pump flow n= 1800 min
-1
118 162 234 324 450
Case pressure pv max bar max. 0,5 bar over p1. pmax = 4 bar abs.
DRIVE
Maximum driving torque - single unit M1 Single Nm 440 600 868 1202 1671
(p
2 max.
, = 100%)
Maximum power consumption - single unit P
1 Single kW 69 94 136 189 265
(p
2 max.
, = 100%; n= 1800 min
-1
)
Maximum driving torque limited to M
1 Comb. Nm 2x440 2x600 2x868 2x1202 2x1671
splined shaft only - comb. unit
21
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Performance
Curves -
066, 090, 130,
180, 250 Series
Theoretical Power Consumption P
0 100 200 300 400 bar
0
400
0 1000 3000 5000 5800 psi
300
200
100
0
50
100
150
200
L/min
250
kW
Operating Pressure
PFX/PVX
0
50
150
200
250
350
hp
300
100
40
60
80
100
USgpm
20
250
180
130
90
066
Effective Outlet Flow
0 100 200 300 400 ba
r
100
50
0 1000 2000 3000 4000 5000 5800 psi
Efficiency (%)
tot.
vol.
Operating Pressure
90
80
70
60
40
30
20
10
0
tot for 100 % Vg
tot for 50 % Vg
tot for 25 % Vg
Outlet Flow and Theoretical
Power Consumption
Volumetric and Overall Efficiencies
Typical at 1500 min-1 with anti-wear oil at 40 cSt
Single displacement pumps: PFX,PVX
For Calculation: P
eff
= P
th/
tot
50 100 200 300 400bar
725psi
Basic Rating Life L10 [h]
1450 2900 4350 5800
3 x 10
3
4
10
5
10
Pump size 090
Operating Pressure
1800 min
1500 min
1000 min
-1
-1
-1
50 100 200 300 400bar
725psi
Basic Rating Life L10 [h]
1450 2900 4350 5800
3 x 10
3
4
10
5
10
Pump size 130
Operating Pressure
1800 min
1500 min
1000 min
-1
-1
-1
50 100 200 300 400bar
725psi
Basic Rating Life L10 [h]
1450 2900 4350 5800
3 x 10
3
4
10
5
10
Pump size 180
Operating Pressure
1800 min
1500 min
1000 min
-1
-1
-1
50 100 200 300 400bar
725psi
Basic Rating Life L10 [h]
1450 2900 4350 5800
3 x 10
3
4
10
5
10
Pump size 066
Operating Pressure
1800 min
1500 min
1000 min
-1
-1
-1
50 100 200 300 400bar
725psi
Basic Rating Life L10 [h]
1450 2900 4350 580
0
3 x 10
3
4
10
5
10
Pump size 250
Operating Pressure
1800 min
1500 min
1000 min
-1
-1
-1
22
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
At maximum displacement
and various speeds.
Performance
Curves -
Operating Data:
Theoretical Bearing Life Time
066, 090, 130,
180, 250 Series
23
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
psi
bar0
Operating Pressure
100 200 300
0 1000 2000 3000 4000 5000
11
10
9
8
7
6
5
4
3
2
1
0
3.0
2.5
2.0
1.5
1.0
0.5
0
USgpm L/min
D
ra
i
n
Fl
ow
PFX/PVX066/090
3
2
1
psi
ba
r
0
Operating Pressure
100 200 300
0 1000 2000 3000 4000 5000
11
10
9
8
7
6
5
4
3
2
1
0
3.0
2.5
2.0
1.5
1.0
0.5
0
USgpm L/min PFX/PVX180
3
2
1
12
13
14
15
16
3.5
4.0
psi
bar0
Operating Pressure
100 200 300
0 1000 2000 3000 4000 5000
11
10
9
8
7
6
5
4
3
2
1
0
3.0
2.5
2.0
1.5
1.0
0.5
0
USgpm L/min
PFX/PVX130
3
2
1
12
13
14
3.5
4.0
psi
bar0
Operating Pressure
100 200 300
0 1000 2000 3000 4000 5000
11
10
9
8
7
6
5
4
3
2
1
0
3.0
2.5
2.0
1.5
1.0
0.5
0
USgpm L/min
PFX/PVX250
3
2
1
12
13
14
3.5
4.0
1 PFX and PVX models at
maximum displacement (PVX
models with type FE, HG or
ES controls i.e. no control oil
flow)
2 PVX in pressure cutoff
mode (flow of pilot stage is
discharged separately)
3 PVX in pressure cutoff
mode (flow of pilot stage is
discharged in case)
Performance
Curves -
Operating Data:
Typical Drain Flow from an
Open-Loop Pump Based on
1500 r/min and 35cSt
24
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
DF, LR Pressure
Compensator/
Power Control
“X” Series - Open loop pump
WVC
S
p
H
0 100 200 300 400 bar
psi
Response Time (ms)(V
null
to V
max
)
100
0
50
2000 4000 6000
250
130/180
066/090
Operating Pressure
p
2
y
Up Down
T
u
= time lag
T= compensating time
g
t
u
T
g
T
T
gu
T
0,9 y max.
Swashplate
yoke angle
pressure
Outlet
Energy saving hydraulic
drives are possible with
pressure compensated
and/or power controlled
pumps, especially in
combination with the
load-sensing option.
DF The system pressure
remains constant for
the entire volume flow
rate. System pressure
can be set either
manually, hydraulically
or electronically. The
standard Hydrokraft
pressure compensator
is pilot operated and
very stable.
LR The p/Q
characteristic curve
is a hyperbola. For
constant speed the drive
torque, i.e. the power
used, is held constant.
The power hyperbola can
be continuously adjusted
between Pmin and
Pmax. Pmin is given by
the minimum set value
of control’s main stage
(app. 20 bar) and power
loss of the pump.
Both controllers can be
combined with another
or with additional
options, for possible
variations see the model
coding and circuit
diagrams. The maximum
flow of the pump can be
limited mechanically to
between 50% and 100%
by screw.
As an additional option
the maximum (or
minimum) flow can also
be limited by a spacer
inside the control
cylinder (position
number 13 in
model coding,
options 4, 5
or 6 in combination with
customer adjustment
specifications position
40-43 for the set values).
This solution is also
recommended for
very rough operating
conditions and the
need of a very exact
repeatability over a long
time period. The setting
must be defined before
ordering and cannot
be modified during
operation.
Typical controller action
(Closing/opening the directional control valve WV)
Q Qmax or Qmin Qmax
C
H
- 50mm ID x 2 meters
Pressure compensator response times
0 100 200 300 400 bar
psi
Response Time (ms)(V
null
to V
max
)
200
0
2000 4000 6000
100
Operating Pressure
250
130/180
066/090
25
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
DF, LR Pressure
Compensator/
Power Control
“X” Series - Open loop pump
BA
Mechanical
adjustment
Minimum pressure
approximately 20 bar (280 psi)
adjustment
Electrical
..DF000A00..
Qmax
Alternatively
..DF000A0K..
Remote port
only
X1
..DF000A0F..
Q+
p
Electrical
..LR000A20..
..LR000A2K... ..LR000A2F...
AB
Mechanical
adjustment
adjustment
X1
Qmax
Remote por
t
only
Alternatively
Q+
p
DF Pressure compensator
DF000A ...
Control valve adjustable
mechanically, electrically
or remote port only
LR Power control with
overriding pressure
limiter LR000A2 ...
Pressure control pilot
valve adjustable
mechanically, electrically
or remote port only
26
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
DF, LR Pressure
Compensator/
Power Control
“X” Series - Open loop pump
AB
X
Mechanical
adjustment
adjustment
Electrical
2
X1
Qmax
..DF000A10..
..DF000A1K..
Remote port
only
Alternatively
..DF000A1F..
Q+
p
AB
X
Mechanical
adjustment
adjustment
Electrical
X
2
1
Alternatively
Qmax
..LR000A30..
..LR000A3K..
Remote port
only
..LR000A3F..
Q+
p
DF Pressure
compensator with
load sensing
DF000A1 ...
Control valve adjustable
mechanically, electrically or
remote port only
LR Power control with
load sensing and
pressure limiter
LR000A3 ...
Pressure control pilot valve
adjustable mechanically,
electrically or remote port
only
27
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
DQ Mooring
Control
“X” Series - Open loop pump
BA
Mechanical
adjustment
Minimum pressure
approximately 20 bar (280psi)
adjustment
Electrical
..DQ000A00..
Qmax
Alternatively
..DQ000A0K..
Remote por
t
only
X1
..DQ000A0F..
Q+
p
-Q
The DQ-control is a
pressure control with
overcenter operation
(2 quadrants). It can
be used eg. for
counterbalanced
systems or applications
where reverse flow
from the system can
drive the pump in
reverse (negative
pump angle) such
as a hydraulic motor.
The DQ-control is only
available for sizes 66, (90
on request), 130 and 180
ccm/rev.
Like the standard
Hydrokraft pressure
compensator this control
pilot operated and very
stable. For performance
data/response time
please refer to the
DF-control.
As an additional option
the maximum (or
minimum) flow can be
limited by a spacer
inside the control
cylinder (position
number. 13 in model
coding, options 4, 5 or 6
in combination with
customer adjustment
specifications position
40-43 for the set values).
This solution is also
recommended for
very rough operating
conditions and the
need of a very exact
repeatability over a long
time period. The setting
must be defined before
ordering and cannot
be modified during
operation.
28
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
HG Manual
Adjustment
Displacement
Control FE
“X” Series - Open loop pump
FE The FE - control is
a displacement control
where the pump flow
is adjusted by a screw.
HG The HG-control is
a displacement control
where the pump flow
can be adjusted by a
handwheel.
The maximum (and/or
minimum) flow can be
limited by a spacer
inside the control
cylinder (position
number 13 in model
coding, options 4, 5 or 6
in combination with
customer adjustment
specifications position
40-43 for the set values).
The setting must be
defined before ordering
and cannot be modified
during operation.
V+
+
0 to + V
max
displacement
29
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
Electric Motor
Displacement
Control ES
“X” Series - Open loop pump
THEORETICAL RESPONSE TIME (SEC) FOR MAX. DISPLACEMENT CHARACTER IN MODEL CODE POS. 26
Size 066 090 130 180 250 250
Freq. Hz 50 60 50 60 50 60
Fast 7 6 18 15 15 13 M
Medium 24 20 35 29 30 25 N
Slow 38 32 54 45 48 40 P
Response time from 0 to +Q
max
V+
Response time from 0 to +V
maximum displacement
A
M
B
L
PVX Response Times ES - Control
The unit is used for
stepless adjustment.
It has a three phase
electric servo motor,
worm gearing and a
switch box with 4
and 8 limit switches
for different positions.
A potentiometer is
also available.
The response times
from zero to maximum
depends on the chosen
ration and the speed of
the servo motor (this
means that during
operation the response
times are not variable.
No pressure/power
limiter possible.
Explosion protection
versions are also
available.
30
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
Pressure Signal
Displacement
Control DP
“X” Series - Open loop pump
p
St
LB
S
Qmax
A
T
P
T
A
B
P
T
A
B
P
TA
B
P
T
M8
D1
The output flow of the
pump is proportional
to the pilot pressure
A separate pilot oil
circuit is necessary.
From this the control
pressure is reduced to
the desired set value
by means of a suitable
pressure control valve
(with P -T line ) and
throttle in P - line 0.8 Ø
(0.03 in).
The DP-control can be
used for steepless flow
control with standard
requirements for
dynamic and precision.
No feedback signal
is needed, an optical
indicator recommended
(position 22 in model
coding, option “V”).
A pilot oil filter can be
mounted in line between
pump and control
(position 35 in model
coding, option “V” or
“E”).
Pressure limiter or
power limiter override
not available ( or such
and other options please
refer to PVW-Series ).
As an additional option
the maximum (and/or
minimum) flow can be
limited by a spacer
inside the control
cylinder (position
number 13 in model
coding, options 4, 5 or 6
in combination with
customer adjustment
specifications position
40-43 for the set values).
This solution is also
recommended for
very rough operating
conditions and the
need of a very exact
repeatability over a long
time period. The setting
must be defined before
ordering and cannot
be modified during
operation.
Pilot
p
ressure
10
20 40 ba
r
30
Q
max
100%
RESPONSE TIME (SEC)
W/ 12 L/MIN PILOT OIL FLOW PILOT PRESSURE P
ST
SIZE (STANDARD) BAR
066/090 0.7 60
130/180 0.9 60
250 1.1 60
PVX Response Times DP - Control
The output flow of the pump is proportional
to the pilot pressure
31
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Controls -
Proportional Valve
Displacement
Control SP
“X” Series - Open loop pump
St1
p
St
M
BA
PT
ABL1/L2
The SP control operates
a hydrostatic drive and
works without throttle
losses within electrically
adjustable limits. This
is done by controlling
delivery flow with
electrical swashplate
angle feedback (electr-
closed-loop control).
All control values are
recorded as an electrical
signal and lead back
to the control card.
The proportional
valve and servo piston
transform the output
signal of the control card
to the desired setting.
This results in a very
precise and dynamic
control. Pressure limiter
override available on
request. Power limiter
override not available
(for such and other
options please refer
to PVW series).
As an additional option
the maximum (and/or
minimum) flow can be
limited by a spacer
inside the control
cylinder (position
number 13 in model
coding, options 4, 5 or 6
in combination with
customer adjustment
specifications position
40-43 for the set values).
This solution is also
recommended for
very rough operating
conditions and the
need of a very exact
repeatability over a long
time period. The setting
must be defined before
ordering and cannot
be modified during
operation.
Electric input signal
0
4
10 V
20 mA
+100%
0
Q
or
PVX RESPONSE TIMES SP - CONTROL
PROPORTIONAL VALVE PILOT PILOT OIL CONTROL RESPONSE
OIL FLOW PRESSURE P
ST
ELECTRONICS TIME UNIT SIZE SERVO PISTON
L/min (Amp. Card) 0 < > V
max
Diameter Stroke Volume
(Usgpm) bar (psi) [ms] cm
3
mm (in) mm (in) cm
3
(in
3
)
Medium Response 60 (857) 250 066 / 090 40/30 (1.57/1.18) 28 (1.10) 15,4 (0.939)
KDG4V3-2C20NMUH760 12 (3.17) 60 (857) ER 9.3-10 350 130 / 180 55/38 (2.16/1.49) 35 (1.37) 43,5 (2.654)
(CETOP 3) 60 (857) 550 250 70/50 (2.76/1.97) 43,5 (1.71) 81 (4.942)
High Response ON REQUEST
(CETOP 5)
The ER9.3-10 and ER 9.4-10 ( for High Response ) digital Amplifier cards are optimized for use with the SP-Control. Please ask
for separate Documentation. Software is available for parameter setting and storing (database function). Contact Eaton to
request free of charge manual - and software CD.
32
58
Ø125 h8
80
160
120
(180)
Ø18
155
210175
15035
M14
154
218 56
68
15
(367)
8
16
58
68
+0.2
0
26
120
246
10 h9
Ø38 k6
41
right
MB
Center bore
DM12 DIN332
MA
A
L5
L2
L1
B
L3
L2
B
L5
4xM10-20deep
W40x1.25x
10aDIN 5480
Center bore
DM12 DIN332
cw
M12-20deep
69.8
35.7
27.8
Ø38
(25)
57.2
1", 6000psi
M12x25deep
Port A
Port B
1 1/2", 3000psi
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PFXS 066
Dimensions in mm
ASystem pressure port SAE 1’’, 415 bar (6000 psi)
BSystem pressure port SAE 1 1/2‘’, 207 bar (3000 psi)
(L1) Drain port 7/8" – 14 UNF
(L2) Ventilation port for vertical mounting M26x1.5
(L3) Ventilation port for vertical mounting G1/4 "
(shaft upwards)
(L5) Oil filling plug M26x1.5
(MA) Gauge port system pressure G1/4"
(MB) Gauge port system pressure G1/4"
(…) Normally plugged
Non-Standard Displacements:
Standard Displacement . . . . . . . . . . . . . . . . . . . . .66 ccm/rev
Reduced Displacement Available . . . . . . . . .55 or 44 ccm/rev
DIRECTION OF ROTATION INPUT OUTPUT
Right Hand Rotation B A
Left Hand Rotation A B
33
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
M12-20deep
77.7
42.88
58
Ø125 h8
80
160
120
(180)
Ø18
155
210175
217.5
150
35
(25)
27.8
57.2
M10
154
218 56
50
68
15
(367)
(372)
8
16
68
58
+0.2
Ø38 k6
10 h9
41
0
26
120
246
right
MB
Center bore
DM12 DIN332
MA
A
L5
L2
L1
B
L3
L2
B
L5
1", 6000psi
4xM10-20deep
M12x25deep
Port A
Port B
W40x1.25x
10aDIN 5480
2", 3000psi
Center bore
DM12 DIN332
cw
Pump
Dimensions -
PFXS 090
Dimensions in mm
ASystem pressure port SAE 1’’, 415 bar (6000 psi)
BSystem pressure port SAE 2‘’, 207 bar (3000 psi)
(L1) Drain port 7/8" – 14 UNF
(L2) Ventilation port for vertical mounting M26x1.5
(L3) Ventilation port for vertical mounting G1/4 "
(shaft upwards)
(L5) Oil filling plug M26x1.5
(MA) Gauge port system pressure G1/4"
(MB) Gauge port system pressure G1/4"
(…) Normally plugged
Non-Standard Displacements:
Standard Displacement . . . . . . . . . . . . . . . . . . . . .90 ccm/rev
Reduced Displacement Available . . . . . . . . . . . . . .75 ccm/rev
DIRECTION OF ROTATION INPUT OUTPUT
Right Hand Rotation B A
Left Hand Rotation A B
34
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PFXS 130
Ø160 h8
224
40 185
271
120
22
W50x1.25x10a
DIN 5480
20
9
78
200
265
100
200
150
22
(505)
Ø63
88.9
50.8
57.2
Ø25
35
68
53.5
82
92
-0.2
27.8
14 h9
Ø50 k6
148
316
0
right
DM16 DIN332
Center bore
4xM12-20deep
M12-20deep
M12-20deep
L1
L2 L1.1
L1
L2
L1
L1.1
MA
A
B
Port B
Port A
B
L1
DM16 DIN332
Center bore
cw
Dimensions in mm
ASystem pressure port SAE 1’’, 415 bar (6000 psi)
BSystem pressure port SAE 2 1/2‘’, 207 bar (3000 psi)
(L1) Drain port M26x1.5
(L1.1) Oil filling plug 1 1/16”-12UNF
(L2) Ventilation port for vertical mounting G1/4"
(MA) Gauge port system pressure G1/4"
(…) normally plugged
DIRECTION OF ROTATION INPUT OUTPUT
Right Hand Rotation B A
Left Hand Rotation A B
Non-Standard Displacements:
Standard Displacement size 130 ...........................130 ccm/rev
Reduced Displacement Available Size 130...115 or 94 ccm/rev
35
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Ø160 h8
224
40
185
271 120
22
W50x1.25x10a
DIN 5480
20
9
78
200
265
100
200
150
2
(505)
Ø63
88.9
50.8
3
68
53.5
82
Ø50 k6
14 h9
92
-0.2
66.7
Ø32
31.8
148
16
316
right
DM16 DIN332
Center bore
4xM12-20deep
M12-20deep
L1
L2 L1.1
L2
L1
L1.1
MA
A
B
Port B
Port A
B
L1
DM16 DIN332
Center bore
A
M14-20deep
L1
cw
B
Pump
Dimensions -
PFXS 180
Dimensions in mm
ASystem pressure port SAE 1 1/4’’, 415 bar (6000 psi)
BSystem pressure port SAE 2 1/2‘’, 207 bar (3000 psi)
(L1) Drain port M26x1.5
(L1.1) Oil filling plug 1 1/16”-12UNF
(L2) Ventilation port for vertical mounting G1/4"
(MA) Gauge port system pressure G1/4"
(…) Normally plugged
DIRECTION OF ROTATION INPUT OUTPUT
Right Hand Rotation B A
Left Hand Rotation A B
Non-Standard Displacements:
Standard Displacement Size 180 ..........................180 ccm/rev
Reduced Displacement Available Size 180............160 ccm/rev
36
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PFXS 250
26
22
(644)
341 164
125
250
230
188
330
350
105
50
Ø200 h6
Ø65 k6
25
10
280
250
+0.2
Ø32
31.8
120.7
69.8
Ø88
66.7
DIN5480
W62x1.25x10a
80
90
18 h9
6
+0.2
187
403
0
117
B
4xM16-32deep
L2
L1 L1.1
DM20 DIN332
Center bore
L1
B
L1
MA
A
Port A
Port B
M16-32deep
M14-24deep
DM20 DIN332
Center bore
MB
clockwise
Dimensions in mm
ASystem pressure port SAE 1 1/4’’, 415 bar (6000 psi)
BSystem pressure port SAE 3 1/2‘’, 35 bar (500 psi)
(L1) Drain port M26x1.5
(L1.1) Oil filling plug 1 5/16”-12UN
(L2) Ventilation port for vertical mounting G1/4"
(MA) Gauge port system pressure G1/4"
(…) normally plugged
DIRECTION OF ROTATION INPUT OUTPUT
Right Hand Rotation B A
Left Hand Rotation A B
Non-Standard Displacements:
Standard Displacement ........................................250 ccm/rev
Reduced Displacement Available.......222, 208 or 194 ccm/rev
37
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
38
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PVXS 066 - 250
DF, Two Stage
Pilot Valve
L12
D8
L14
L13
D10
L11
D9
D11
View X
3000/500psi
Port "B"
Port "A"
6000psi
L19
Side ports -
Pressure compensator
DF000A ...
1. Pilot valve (2nd Stage)
2. Pressure compensator
(1st stage)
G1/4’’x12,5-deep; option for an additional pilot valve
and/or discharge valve of the pressure compensator
Two drain ports, one supplied plugged
M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
G1/4"x12.5-deep gauge port supplied plugged
MA
L2
L1
X1
DIRECTION OF ROTATION CONTROL INPUT OUTPUT
Right Hand Rotation To + Vmax B A
To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT
3000(500)PSI, INLET 6000PSI, OUTLET KG
066 1 1/2’’ 1’’ 55
090 2‘’ 1’’ 57
130 2 1/2’’ 1’’ 111
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226
SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12
h9
066 210 116 160 235 130 180 10 116 58 185 218 —
090 210 116 160 235 130 180 10 116 58 185 218 157.5
130 260 140 200 265 224 224 14 140 70 185 218 —
180 260 140 200 265 224 224 14 140 70 185 218 —
250 325 175 250 330 280 280 18 175 87.5 185 218 —
SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13
h8 k6 Light Execution SAE 475
066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF
090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF
Dimensions in mm
39
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
B6
B3
H2
H9
H8
H7
H3
B10
B11
H6
B4
B7 h9
B2
B5
B1
D12
H1
B9
B8
1
2
H4
+0.2
24
cw
MA
X1
L1L1
L1 L1
B12
H5
L2
L9
L3
L1
L6
L4
L8
L5
L7
D3
D6
L15
L16
L17
D5
L10
L18
L20
Center bore
DM16 DIN332
+Vmax
0
orifice
inside
of the
control
valve
X1
M18x1.5-12deep
Size 090
L1
L2
B
D1 h8
D4
D2 k6
MA
Size 090
X
A
B
L1
L1
D13
L3
SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9
+0.2
066 227 162 90 41 93 53 88 139 91
090 227 162 90 41 93 53 88 139 91
130 283 207 113 53.5 117 64 110 174 91
180 283 207 113 53.5 117 64 110 174 91
250 354 260 140 69 146 77 138 217 91
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 50 10 72.5 245.6 245.6 31
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 50 10 72.5 245.6 245.6 31
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 50 12 72.5 316 309 33
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 50 12 72.5 316 309 33
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 56 — 72.5 403 403 35
Splined shaft
Dim. See page 51
40
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PVXS 066 - 250
DF, with Load
Sensing Valve
D8
L14
D10
L12
L11
L13
D9
D11
View X
Port "B"
3000/500psi
6000psi
Port "A"
L19
Side ports -
Pressure compensator
with Load Sensing
DF000A1 ...
1. Pilot valve (2nd Stage)
2. Pressure compensator
(1st stage)
3. Flow valve
G1/4’’x12,5-deep; option for an additional pilot valve
and/or discharge valve of the pressure compensator
G1/4’’x12,5-deep; load sensing pilot port
Two drain ports, one supplied plugged
M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
G1/4"x12.5-deep gauge port supplied plugged
MA
L2
L1
X2
X1
DIRECTION OF ROTATION CONTROL INPUT OUTPUT
Right Hand Rotation To + Vmax B A
To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT
3000(500)PSI, INLET 6000PSI, OUTLET KG
066 1 1/2’’ 1’’ 55
090 2‘’ 1’’ 57
130 2 1/2’’ 1’’ 111
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226
SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12
h9
066 210 116 160 235 130 180 10 116 58 185 218 —
090 210 116 160 235 130 180 10 116 58 185 218 157.5
130 260 140 200 265 224 224 14 140 70 185 218 —
180 260 140 200 265 224 224 14 140 70 185 218 —
250 325 175 250 330 280 280 18 175 87.5 185 218 —
SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13
h8 k6 Light Execution SAE 475
066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF
090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF
Dimensions in mm
41
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
L5
L7
L9
L4
L8
L2
L1
L18
H3
B9
B8
B5
D2 k6
D1 h8
B4
H8
H7
H6
D12
H9
B2
L6
D3
L10
H2
L16
L15
H1
B6
B1
L3
D7
B3
B7 h9
B10
B11
L17
H5
D6
D5
D4
H4
+0.2
1
3
2
Center bore
DM16 DIN332
MA
X2
X1
Size 090
MA
M18x1.5-12deep
+Vmax
0
Size 090
cw
orifice
inside
of the
control
valves
X
B12
L1 L1
B
L1
L1
L2
A
B
L1
L1 L1
D13
L3
SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9
+0.2
066 227 162 90 41 93 53 88 139 132
090 227 162 90 41 93 53 88 139 132
130 283 207 113 53.5 117 64 110 174 132
180 283 207 113 53.5 117 64 110 174 132
250 354 260 140 69 146 77 138 217 132
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 50 10 67.5 245.6 245.6
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 50 10 67.5 245.6 245.6
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 50 12 67.5 316 306
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 50 12 67.5 316 306
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 56 — 70.5 403 403
Splined shaft
Dim. See page 51
42
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
L14
L13
D10
D1
D2
D11
View X
Port "A"
6000psi
L19
B6
B3
H2
D4
B10
B11
H4
B7 h9
+0.2
B1
H1
cw
1
2
L1
L1
Side ports -
Power Control LR
(with pressure limiter)
LR000A2 ...
1. Pilot valve (2nd Stage)
2. Pressure compensator
(1st stage)
3. Constant power control
G1/4’’x12,5-deep; option for an additional pilot valve
and/or discharge valve of the pressure compensator
Two drain ports, one supplied plugged
M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
G1/4"x12.5-deep gauge port supplied plugged
MA
L2
L1
X1
DIRECTION OF ROTATION CONTROL INPUT OUTPUT
Right Hand Rotation To + Vmax B A
To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT
3000(500)PSI, INLET 6000PSI, OUTLET KG
066 1 1/2’’ 1’’ 55
090 2‘’ 1’’ 57
130 2 1/2’’ 1’’ 111
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226
SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12
h9
066 210 116 160 235 130 180 10 116 58 185 218 —
090 210 116 160 235 130 180 10 116 58 185 218 157.5
130 260 140 200 265 224 224 14 140 70 185 218 —
180 260 140 200 265 224 224 14 140 70 185 218 —
250 325 175 250 330 280 280 18 175 87.5 185 218 —
SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13
h8 k6 Light Execution SAE 475
066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF
090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF
Dimensions in mm
Pump
Dimensions -
PVXS 066 - 250
LR, with Pressure
Limiter
L12
D8
L11
D9
2
3000/500psi
Port "B"
43
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
H5
L2
L9
L3
L1
H9
H8
L6
H7
H3
L4
L8
L5
L7
D3
H6
B4
D7
D6
L15
L16
L17
D5
L10
B2
B5
D12
L18
B9
B8
L20
Center bore
DM16 DIN332
+Vmax
0
X1
M18x1.5-12deep
Size 090
MA
X1
orifice
inside
of the
control
valves
3
L1
L1
L2
B
B12
D1 h8
D2 k6
MA
Size 090
3
X
A
B
L1
L1
D13
L3
SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9
+0.2
066 227 162 90 41 93 53 88 139 91
090 227 162 90 41 93 53 88 139 91
130 283 207 113 53.5 117 64 110 174 91
180 283 207 113 53.5 117 64 110 174 91
250 354 260 140 69 146 77 138 217 91
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 50 10 72.5 245.6 245.6 161
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 50 10 72.5 245.6 245.6 161
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 60 12 72.5 316 306 171
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 60 12 72.5 316 306 171
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 112 — 75.5 403 403 199.5
Splined shaft
Dim. See page 51
44
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PVXS 066 - 250
ES
H3
B9
B8
B5
D3
B4
H8
D12
H6
H7
B2
D14
DM16 DIN332
Center bore
MA
B12
L1
L1
Side ports -
Electric Motor
Displacement Control
ES*00A ...
Two drain ports, one supplied plugged
M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
G1/4"x12.5-deep gauge port supplied plugged
MA
L2
L1
DIRECTION OF ROTATION CONTROL INPUT OUTPUT
Right Hand Rotation To + Vmax B A
To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT
3000(500)PSI, INLET 6000PSI, OUTLET KG
066 1 1/2’’ 1’’ 55
090 2‘’ 1’’ 57
130 2 1/2’’ 1’’ 111
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226
SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12
h9
066 210 116 160 235 130 180 10 116 58 276.5 334.5 —
090 210 116 160 235 130 180 10 116 58 276.5 334.5 157.5
130 260 140 200 265 224 224 14 140 70 288.5 368.5 —
180 260 140 200 265 224 224 14 140 70 288.5 368.5 —
250 325 180 250 330 280 280 18 175 87.5 332.7 434.7 —
SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13 D14
h8 k6 Light Execution SAE 475
066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF 110.5
090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF 110.5
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF 110.5
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF 110.5
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF 123
Dimensions in mm
45
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
L12
D8
D
L
L13
L11
D9
D11
View X
L18
Port "B"
3000/500psi
6000psi
Port "A"
L16
L5
D7
L3L4
L8
L10
D3
H7
D14
H5
L17
L1
L2
L6
L7
L9
D6
D5
L15
M18x1.5-12deep
Size 090
DM16 DIN332
Center bore
+Vmax
0
A
L2
L1
B
D2 k6
D1 h8
Size 090
MA
X
B
L1
L1
A
D13
L3
B6
B1
B7 h9
H2
H1
B3
B11
B10
D4
H4
+0.2
cw
L1
L1
SIZE H1 H2 H3 H4 H5 H6 H7 H8
+0.2
066 227 162 90 41 93 53 122 168
090 227 162 90 41 93 53 122 168
130 283 207 113 53.5 117 58.5 165 214
180 283 207 113 53.5 117 58.5 165 214
250 354 260 140 69 146 77 198 262
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 78 153.5 7245.6 245.6
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 78 153.5 245.6 245.6
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 100 175.5 316 306
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 100 175.5 316 306
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 88 163.5 403 403
Splined shaft
Dim. See page 51
46
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PVXS 066 - 250
Side ports -
Pressure Signal
Displacement Control
DP*00A ...
1. P ressure proportional valve
2. Pressure limiter
G1/2’’ Tank port
G3/4’’ Suction port of pilot pump
G3/4’’ Port of pilot pressure
Port of pilot pressure Size 006/090=M14x1.5
Size 130/180=M16x1.5
Size 250=G1/2’’(M22x1.5)
Two drain ports, one supplied plugged
M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
G1/4"x12.5-deep gauge port supplied plugged
MA
L2
L1
PSt1
PSt
SSt
T
DIRECTION OF ROTATION CONTROL INPUT OUTPUT
Right Hand Rotation To + Vmax B A
To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT
3000(500)PSI, INLET 6000PSI, OUTLET KG
066 1 1/2’’ 1’’ 55
090 2‘’ 1’’ 57
130 2 1/2’’ 1’’ 111
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226
SIZE B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12
h9
066 210 116 160 235 130 180 10 116 58 52 182.5 —
090 210 116 160 235 130 180 10 116 58 52 182.5 157.5
130 260 140 200 265 224 224 14 140 70 52 182.5 —
180 260 140 200 265 224 224 14 140 70 52 182.5 —
250 325 180 250 330 280 280 18 175 87.5 52 182.5 —
SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12 D13 D14
h8 k6 Light Execution SAE 475
066 125 38 M12 18 M8 M22x1.5 M10 24 38 M12 24 25 M12 21 — 7/8-14UNF 64
090 125 38 M12 18 M8 M22x1.5 M10 20 50 M12 24 25 M12 21 — 7/8-14UNF 64
130 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 25 M12 20 M20 1 1/16-12UNF 88
180 160 50 M16 22 M10 M26x1.5 M12 20 62 M12 20 32 M14 20 M20 1 1/16-12UNF 88
250 200 65 M20 26 M12 M33x2 M16 32 90 M16 32 32 M14 24 M24 1 5/16-12UNF 88
Dimensions in mm
D2 k6
D1 h8
L12
Size 090
MA
X
B
A
L1
L1
SSt
T
PSt1
D13
L3
B5
H3
B9
B8
H9
1
2
H7
H8
B2
B4
D12
H6
D3
B12
Cent
DM1
MA
L1
Splined shaft
Dim. See page 51
47
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
H10
L21
L10
3
L3
L4
L5
L8
L20
D6
L9
L18
L2
L1
L7
L6
D3
L15
H5
D5
L17
D14
L16
L22
M18x1.5-12deep
Center bore
DM16 DIN332
Size 090
Pilot pump
+Vmax
MA
Cetop NG6
DIN24340
View X
L2
6000psi
Port "A"
B
L1
PSt
T
PSt1
SIZE H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 H11
+0.2
066 227 162 90 41 93 53 88 137 127 97 113
090 227 162 90 41 93 53 88 137 127 97 113
130 283 207 113 53.5 117 64 110 170 127 97 131
180 283 207 113 53.5 117 64 110 170 127 97 131
250 354 260 140 69 146 77 138 214 127 124 167
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 L21 L22
066 342 274 150 35 8 58 16 26 120 28 35.7 69.8 27.8 57.2 267 104 46 245.6 245.6 73.5 122.6 230.6
090 342 274 150 35 8 58 16 26 120 28 42.88 77.77 27.8 57.2 267 104 46 245.6 245.6 73.5 122.6 230.6
130 483 391 185 40 9 82 20 32 148 36 50.8 89 27.8 57.2 342 128 46 316 306 73.5 122.6 336
180 483 391 185 40 9 82 20 32 148 36 50.8 89 31.8 66.7 342 128 46 316 306 73.5 122.6 336
250 622 505 230 50 10 105 25 41 187 42 69.8 120.7 31.8 66.7 387 150 46 403 403 73.5 122.6 437
B6
H2
H1
B3
B1
B7 h9
B11
H4
B10
D4
+0.2
cw
L1
L1
L11
D8
L12
L14
D10
L13
D9
Pilot pump
D11
View X
3000/500psi
L19
Port "B"
SSt
6000psi
Port "A"
T
Splined shaft
Dim. See page 51
48
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
cw
L1
L1
B3
B6
B1
B13
H3
H2
H1
B2
1
2
3
D4
D11
D9
Port "A"
Port "B"
0
0
L11
D8
L12
L13
D10
L14
Pump
Dimensions -
PVXS 066 - 250
Side ports -
Proportional Valve
Displacement Control
SPC03A.....E...
1. P roportional valve
2. Pressure limiter
3. Filter
G1/2”
G1/2”
G1/4”
Two drain ports, one supplied plugged
M18x1, 5x12-deep supplementary drain, or bleed plug.
Must be drained in addition to if the pump is installed
with the shaft input end pointing upwards.
G1/4"x12.5-deep gauge port supplied plugged
MA
L2
L1
Mst
Pst
T
DIRECTION OF ROTATION CONTROL INPUT OUTPUT
Right Hand Rotation To + Vmax B A
To - Vmax A B
Left Hand Rotation To + Vmax A B
To - Vmax B A
SIZE SAE-FLANGE “B” SAE-FLANGE “A” WEIGHT
3000(500)PSI, INLET 6000PSI, OUTLET KG
066 1 1/2’’ 1’’ 55
090 2‘’ 1’’ 57
130 2 1/2’’ 1’’ 111
180 2 1/2’’ 1 1/4’’ 113
250 3 1/2’’ 1 1/4’’ 226
SIZE B1 B2 B3 B4 B5 B6 B7 B8 B12 B13
h9
066 210 116 160 235 130 180 10 116 — 165
090 210 116 160 235 130 180 10 116 157.5 165
130 260 140 200 265 224 224 14 140 — 190
180 260 140 200 265 224 224 14 140 — 190
250 325 175 250 330 280 280 18 175 — 221
SIZE D1 D2 D3 D4 D5 D6 D7 DEEP D8 D9 DEEP D10 D11 DEEP D12
h8 k6 Light Execution
066 125 38 M12 — 7/8-UNF M22x1.5 M10 20 38 M12 24 25 M12 21 —
090 125 38 M12 18 7/8-UNF M22x1.5 M10 20 50 M12 24 25 M12 21 —
130 160 50 M16 22 1 1/16-UNF M26x1.5 M12 20 62 M12 20 25 M12 20 M20
180 160 50 M16 22 1 1/16-UNF M26x1.5 M12 20 62 M12 20 32 M14 20 M20
250 200 65 M20 26 1 1/16-UNF M33x2 M16 32 90 M16 32 32 M14 24 M24
Dimensions in mm
49
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
B8
B5
B4
D7
Center bore
DIN332
MA
M18x1.5-12deep
+Vmax
0
only Size 090
D12
D5
D6
Prop. Valve
Filter with
electr.
Contamination
Indicator
Pilot Pressure
Compensator
PSt
MSt
L2
L1
L1
L1
B
H8
H7
H6
12
174
H4
L3
L4
L8
D3
130 173
L5
L2
L18
L10
L9
L7
L6
L16
L15
L1
El. position indicator
only Size 090
MA
T
View X
T
D5
X
L1
L1
B
A
D1
B7
D2
L19
B12
L3
SIZE H1 H2 H3 H4 H5 H6 H7 H8
+0.2
066 227 162 90 41 93 53 88 139
090 227 162 90 41 93 53 88 139
130 283 207 113 53.5 117 64 110 176
180 283 207 113 53.5 117 64 110 176
250 354 260 140 69 146 77 138 220
SIZE L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L18 L19 L20 L21
066 342 274 150 35 8 58 16 26 120 185 35.7 69.8 27.8 57.2 328 576 245.6 245.6 68 58
090 342 274 150 35 8 58 16 26 120 185 42.88 77.77 27.8 57.2 328 576 245.6 245.6 68 58
130 483 391 185 40 9 82 20 32 148 229 50.8 89 27.8 57.2 451 738 316 306 78 68
180 483 391 185 40 9 82 20 32 148 229 50.8 89 31.8 66.7 451 738 316 306 78 68
250 622 505 230 50 10 105 25 41 187 281 69.8 120.7 31.8 66.7 579 931 403 403 90 80
Splined shaft
Dim. See page 51
50
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
B1
33
89.8
89.8
146
Ø101.6
D1
12
9
D2
For SAE"B",
splined shaft,
16/32 DP-13 teeth
O-ring supplied
loose with PV
p
um
p
H7
Ø82.58
L1
10
22
L2
H
106.4
1
130
+0.03
L3
M10-18deep
For SAE"A",
splined shaft,
16/32 DP-9 teeth
loose with PV pump
O-ring supplied
H
Ø82.58
22
102
130
106.4
L1
10
+0.03
L2
L3
M10-20deep
16/32 DP-9 teeth
For SAE"A", splined shaft,
loose with PV pump
O-ring supplied
Pump
Dimensions -
PVXS Thru-Drive
Mounting, Thru-Drive Options
SAE “A” and SAE “B”
PVX 066 / 090
SAE “A”
PVX 130 / 180 / 250
SAE “A”
PVX 130 / 180 / 250
SAE “B”
SIZE THROUGH SHAFT B1 D1 D2 L1 L2 L3 H
066/090 SAE “A” — — — 47 60 81 53
130/180 SAE “A” 224 M20-30 deep M12-20 deep 28 62 81 64
SAE “B” — — — — 62 81 64
250 SAE “A” 280 M24-38 deep M12-24 deep 28 56 91 77
SAE “B” — — — — 56 91 77
51
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
DIN5480
W62x1.25x10a
90
80
Center bore
DM20 DIN332
78
68
W50x1.25x10a
DIN 5480
Center bore
DM16 DIN332
Center bore
DM12 DIN332
W40x1.25x10a
DIN 5480
68
58
Pump
Dimensions -
Splined Shafts
For Variable Displacement
Pumps (PVXS) Only
Size 066 / 090
Size 130 / 180
Size 250
52
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Pump
Dimensions -
PVXS SAE 4-Bolt
Mounting Pads
1
2
0,2 bar
(3 psi)
check
L
L
1
0,2 bar
(3 psi)
check
3
L
L
DIM. CODE 61 SERIES CODE 62 SERIES
1 1/2" 2" 2 1/2" 3 1/2" 1" 1 1/4"
A38506290 2532 max
B 35,7 42,9 50,8 69,8 27,8 31,8
C 69,8 77,8 89 120,7 57,2 66,7
D M12x20 M12x20 M12x20 M16x26 M12x18 M14x24
PFX / PVX 066 Inlet •
Outlet •
PFX / PVX 090 Inlet •
Outlet •
PFX / PVX 130 Inlet •
Outlet •
PFX / PVX 180 Inlet •
Outlet •
PFX / PVX 250 Inlet •
Outlet •
D
B
C
ÿA
Thru-drive Shaft Output Torque
MAX. OUTPUT TORQUE, NM (LB.FT)
Pump Keyed Shaft Keyed Shaft Splined
Size Increasing Load Increasing Load Shaft
066 520 (383) 260 (190) 660 (485)
090 520 (383) 260 (190) 660 (485)
130 720 (530) 360 (265) 900 (665)
180 720 (530) 360 (265) 900 (665)
250 1400 (1032) 1400 (1032) 2500 (1843)
Installation Drain
piping
Shaft up
Shaft
down
53
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Application Data -
Fluid
Recommendations
Case Flushing
Requirements
A check valve must not
be used in the drain
pipe. The drain pipe
must interminate below
the oil level in the
reservoir.
For all other conditions
with low pressure <20
bar (<300 psi) and low
flow (<10% of Q
max
)
case flushing is required.
For operation with
special fluids HFB and
HFC, case flushing is
recommended.
Flushing Flow
Flushing flow via the
pump case should be
>1% of maximum pump
flow. Maximum flushing
flow depends on case
pressure.
Notes:
•
All listed ratings are
based on the use of
a good quality fluid.
•
Alternative fluids have
a reduced tolerance
for contamination over
petroleum base fluids.
Good filtration is
therefore critical.
•
The pumps will provide
exceptional life when
used with a good
quality clean fluid
at the pump ratings
specified for that fluid.
Fluids
Pumps in the catalog are
primarily designed
to operate with
conventional petroleum
based hydraulic oil.
Alternative fluids and
restrictions:
•
Fluid maintenance
is critical to the
durability of all
hydraulic components,
and particularly so
with hydraulic pumps.
This becomes even
more of a factor when
alternative fluids are
used. All types of
alternative fluids
require extensive
maintenance in order
to maintain proper
levels of water
content, acidity,
viscosity and
contamination.
Fluid Cleanliness
These pumps are
rated for anti-wear
petroleum fluids with
a contamination level
of 18/15/13 per ISO
4406. Operation in
fluids with levels more
contamination than this
is not recommended
and may reduce the
life of the pump
components. Fluids
other than petroleum,
severe service cycles,
or temperature extremes
are cause for adjustment
of these codes. Please
contact your Eaton
representative for
special duty cycle
recommendations.
Eaton pumps, as
well as any variable
displacement piston
pumps, will operate
with apparent
satisfaction in fluids up
to the rating specified
here. Experience has
shown, however, that
pump and hydraulic
system life is not
optimized with high
fluid contamination
levels (high ISO
cleanliness codes).
Proper fluid condition
is essential for long
and satisfactory life of
hydraulic components
and systems. Hydraulic
fluid must have the
Fluid Cleanliness
correct balance of
cleanliness, materials,
and additives for
protection against
wear of inclusion of air.
Essential information
on the correct methods
for treating hydraulic
fluid is included in Eaton
publication 561- "Vickers
Guide to Systemic
Contamination Control"-
available from your
local Eaton distributor.
In this publication,
filtration and cleanliness
levels for extending the
life of axial piston
pumps and other
system components
are listed. Included is an
excellent discussion of
the selection of products
needed to control fluid
condition.
Ordering Procedure
When ordering please
specify full model
designation of items
required; see "Model
Codes" section of
this catalog.
Note the following:
•
Designation of variable
displacement pumps
must include the
supplementary
designation of the
required control.
FLUIDS
Max. Max. Recommended Max
Pressure Speed Seal Operating Bearing
Type Classification Bar rpm Material Temperature °C Life
Oil in Water Emulsion HFAE Not Rated 0
Water in Oil Emulsion HFB 250 1800 Fluorocarbon 49 50%
Water Glycol HFC 250 1800 Fluorocarbon 49 25%
Phosphate Ester HFDR 350/420 1800 Fluorocarbon 66 100%
Polyol Ester HFDU 350/420 1800 Fluorocarbon 66 100%
54
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Notes
55
EATON Vickers Hydrokraft Open Loop Piston Pumps V-PUPI-TM004-E March 2003
Notes
Eaton
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952 937-9800
Fax: 952 974-7722
www.hydraulics.eaton.com
Eaton
20 Rosamond Road
Footscray
Victoria 3011
Australia
Tel: (61) 3 9319 8222
Fax: (61) 3 9318 5714
Eaton
Dr.-Reckeweg-Str. 1
D-76532 Baden-Baden
Germany
Tel: (49) 07221 682-0
Fax: (49) 07221 682-788
Vickers
© 2003 Eaton Corporation
All rights reserved
Printed in USA
Document No. V-PUPI-TM004-E