MECHANICAL DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DESCRIPTION
#8 SAE, inline check valve.
OPERATION
The IM-CVA allows ow from (2) to (1), while normally blocking oil ow from (1) to (2). The valve has a guided
check ball, which is spring-biased closed until sufcient pressure is applied at (2) to open to (1).
IM-CVA INLINE CHECK VALVE
Nominal Flow 8 GPM (30 LPM)
Rated Operating Pressure 3000 PSI (207 bar)
Typical Internal Leakage
(150 SSU) 0-5 drops/min
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .53 lbs (.24 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
VALVE SPECIFICATIONS
HYDRAULIC SYMBOL
PERFORMANCE
Actual Test Data (Cartridge Only)