MECHANICAL DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DESCRIPTION
#6 SAE, inline shuttle valve.
OPERATION
The IM-CSB allows ow from the higher pressure of (1) or (3) to (2). The valve is commonly
used as a load sense to direct oil from the pressure side of a bidirectional hydraulic motor
to a pressure released hydraulic brake.
FEATURES
• Hardened parts for long life.
IM-CSB INLINE SHUTTLE VALVE
Nominal Flow Max 10 GPM (38 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Typical Internal Leakage
(150 SSU) 1 cu in/min (16 ml/min)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .28 lbs (.13 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
VALVE SPECIFICATIONS
HYDRAULIC SYMBOL
PERFORMANCE
Actual Test Data (Cartridge Only)