MECHANICAL DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DESCRIPTION
#6 SAE, inline shuttle valve.
OPERATION
The IM-CSB allows ow from the higher pressure of (1) or (3) to (2). The valve is commonly
used as a load sense to direct oil from the pressure side of a bidirectional hydraulic motor
to a pressure released hydraulic brake.
FEATURES
• Hardened parts for long life.
IM-CSB INLINE SHUTTLE VALVE
Nominal Flow Max 10 GPM (38 LPM)
Rated Operating Pressure 3500 PSI (241 bar)
Typical Internal Leakage
(150 SSU) 1 cu in/min (16 ml/min)
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -40° to 250°F (-40° to 120°C)
Weight .28 lbs (.13 kg)
Operating Fluid Media General Purpose Hydraulic Fluid
VALVE SPECIFICATIONS
HYDRAULIC SYMBOL
PERFORMANCE
Actual Test Data (Cartridge Only)
MECHANICAL DIRECTIONAL CONTROLS
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526
mail: delta@delta-power.com • www.delta-power.com
WARNING: the specications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specic application should not be undertaken
without independent study, evaluation, and testing for suitability.
W 51 / 12-2022
DIMENSIONS
ORDERING INFORMATION
IM-CSB –
OPTIONS
Buna Standard 00
Viton Standard V0