The PVG 48 program now offers an inlet module with
selectable Open Center/Closed Center configuration
in same module.
The PVP 48 OC/CC inlet module is intended for
hydraulic systems with either fixed or variable
displacement pumps and can easily be changed/
configured according to the system and valve
requirements for the hydraulic system.
The module is designed to interface directly in the
portfolio with PVG 48/32/16.
Features
•
Can be configured as OC and CC by
moving a plug
•
20-35 bar margin pressure
•
Load sense (LS) relief valve
•
Pilot supply for PVE and PVH/PVHC
•
PVLP 63 shock valve in P for initial
pressure peak
•
Internal check valve connection
between T0 and T if T0 is not connected
externally
•
PVPC option for external pilot supply
source
•
Compatible with PVB modules with and
without T0.
Application notes
T0 must be connected externally when
there is:
•
High T pressure
•
Risk of losing T-connection
•
High T0 flow
‒
Large valve with PVEA
‒
Constant control of many functions
simultaneously
Technical data
Maximum pressure P-port continuous 350 bar [5075 psi]
P-port intermittent 400 bar [5800 psi]
T-port static/dynamic 25/40 bar [365/580 psi]
Nominal flow
360 l/min [95 US gal/min]
Comprehensive technical literature is
online at powersource.danfoss.com.
Data Sheet
danfoss.com
Module
PVP 48 OC/CC
©
Danfoss A/S, 2026 AI553572744888en-000102 | 1
OC/CC configuration
The change between OC and CC configurations is made by
moving an M6 plug from one location to another. In open center
configuration, the M6 plug must be placed in the P channel (1),
and in closed center configuration, the M6 plug must be placed
in the LS channel (2).
Schematic
Versions available
Part Number Circuit
Type
Port P Port T Port Actuator
type
PPRV
(bar)
11341941 CC SAE #16 #20 PVE 13,5
11341986 CC BSP G1 G1 ¼ PVE 13,5
11341992 CC SAE #16 #20 PVHC 23
11341968 CC BSP G1 G1 ¼ PVHC 23
11341966 OC BSP G1 G1 ¼ PVE 13,5
11341970 OC SAE #16 #20 PVE 13 ,5
11341967 OC BSP G1 G1 ¼ PVHC 23
11341969 OC SAE #16 #20 PVHC 23
Performance
Neutral by-pass pressure drop characteristics
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |
©
Danfoss A/S, 2026 AI553572744888en-000102