Innovation in HydraulicsConcentric AB
HE POWER PACKS
Concentric AB-He1000 He2000 He2200-GB-2011-7
2
HE POWER PACK CONCEPT 4 - 5
ADAPTOR He1000 6 - 7
ADAPTOR He2000 8 - 9
ADAPTOR He2200 10
PUMPS AND DC MOTORS 11 - 18
TECHNICAL INFORMATION AND HE BOX 19 - 23
POWER PACK CODE KEY 24 - 26
The right to modi cations for technical improvements is reserved.
TABLE OF CONTENTS
Concentric AB-He1000 He2000 He2200-GB-2011-7
3
THE POWER OF HE
Pictures above are used with the kind permission of Scania and Jan Knodt.
Concentric (formerly Haldex) is one of
the world’s leading manufacturers of
hydraulic power packs. In recent years, we
have focused on strategically important
markets, and the result is a new series
of high performance hydraulic power
packs. The HE series represents a further
development of the universal technical
platform developed by Concentric,
worldwide.
HE Power Packs are optimized for
demanding applications. They are de-
signed for use in trucks operating in harsh
climates, or for heavy materials handling
with long service intervals. Applications
that demand high performance and
superb quality. We have also prioritized
customers’ wishes for greater  exibility
and better cost-e ciency.
The result is an extremely versatile
platform, which uses standard com-
ponents and can handle most of the
applications the market demands. It
lets you cut your stock of hydraulic
components down to a minimum and
radically reducing the need for specially
developed components.
HE Power Packs make it easier to build
short series of special applications cost
e ciently.
Concentric (www.concentricAB.com),
headquartered in Stockholm, Sweden,
is an innovator in  ow control and  uid
power, supplying proprietary systems
and components for trucks, buses and
industrial vehicles, worldwide. With
1,156 employees and sales of 1,977
million Swedish Kronor, Concentric AB is
listed on the Stockholm Stock Exchange .
The company operates globally and
enjoys global advantages: secure supply
lines, close contact with customers on
development and a universal technical
platform that will always  t your product
-- no matter where in the world it is
manufactured.
The New He2200 High Flow
Adaptor
The He2000 has for many years been a
success. The performance and flexibility
together has created a wide customer base.
The need for more sophisticated systems
at the same envelope size is one of the
elements that is the basis for the He II
adaptor.
Within the envelope size of an He2000 we
have made it possible to integrate up to 3
cartridge valves for single acting, 2 x single
acting or double acting functions directly
into the adaptor without external manifolds.
Additionally, larger  ow control valves can
be mounted to accept higher return  ows at
eg lowering at high speed. The relief valve
can easily be adjusted from the outside.
In the He2200 version, the pump and motor
are equipped with splined drive shafts that
improve the life of each, especially at
applications with many starts and stops.
All in all, the He2200 offers a cost and
space efficient solution and improved
performance.
Concentric AB-He1000 He2000 He2200-GB-2011-7
4
1,5 kW
ELECTRONIC
SPEED
CONTROLLER
STANDARD 2/2
SOFT START/STOP 2/2
PROPORTIONAL 2/2
STANDARD 4/2
0,3 kW
0PTIONAL
LOW NOISE MOTOR
2,0 kW
0,24 - 2,0 cm
3
1,0 kW
HE POWER PACK CONCEPT
The HE Power Pack is based on a versatile platform that allows you to
combine 80-134 mm motors (0.3-4.5 kW) with a variety of pumps (0.24-
5.7 cc/rev). A unit can individually control several hydraulic cylinders.
The core of the system consists of 3 di erent adaptors with alternative
shapes and variable assembly direction.
Concentric AB-He1000 He2000 He2200-GB-2011-7
5
3,0 kW
0,5 - 5,5 L
1,0 - 12,0 L
4,5 kW
STANDARD 2/2
SOFT START/STOP 2/2
PROPORTIONAL 2/2
OPTIONAL
LOW NOISE
WQ-PUMP
0,8 - 5,7 cm
3
He1000 / He2000 / He2200
Start switch
Start switch with high IP protection class
and silverplated contacts meets tough
demands for a long, problem-free service life.
Oil reservoir
The standard unit is equipped with a transparent
plastic reservoir with 0.5-4.0 litre usable volume,
or a 1.5-12.2 litre steel reservoir.
The following pages contain more information
on the HE power range. If you have any
questions, please do not hesitate to contact
our local sales o ce or distributor, or any of
our factories.
Check valve
Adaptors
Three di erent adaptors with two
alternative mounting directions: the smaller
He1000 adaptor, the larger He2000 and
He2200.
AC Operation
Flanges for 71/80/91/100 B14 AC motors
permit the installation of motors rated at
0.25-4 kW/1500 rpm or 0.37-4 kW/2800 rpm.
AC mounting only with HE 2000 adaptor.
Motors
DC motors,12/24/48 volt. E cient motors
with long service life, long service interval
and low power
consumption.
Special noise
reduced motors (LSM)
available.
Pump
Pressure-balanced gear pumps of our own
design are extremely e cient, with low
noise.
Special noise reduced pumps (WQ)
available.
Valves
Screw-in cartridge valves with a standard
cavity are available in 2/2, 3/2, or 4/2 versions.
Cetop 2, Cetop 3, and additional cartridge
valve blocks are available for up to 4 indivi-
dual functions.
Constant- ow regulator
A built-in pressure-compensated  ow
regulator can be added, providing pressure
compensated lowering speed between 2
and 17,5 lpm regardless of load.
Relief valves
Flushed low-pro le non-blocking relief
valves provide high security. One model
covers the entire 50-250 bar setting
range, and meets tough demands for
dependability and life expectancy.
Concentric AB-He1000 He2000 He2200-GB-2011-7
6
A
A
B
M
G 1/4" THD. x13
B
B
65.7
18
31.3
ADAPTOR He1000
AA000 Adaptor prepared for blockmounted valves or pump unit.
HE ADAPTORS AND VALVES
He1000
He2000
He2200
PRESSURE PORT
G 1/4" THD. x13
B
A
A
M
AL012
AL024
AL230
Adaptor with 12 or 24 VDC,
4/2 cartridge valve
integrated in adaptor.
AE012
AE024
AE230
Adaptor with 12 or 24 VDC, 2/2 cartridge valve,
normally closed. Standard DIN 43650 connection
or optional “Kostal’’ or “AMP junior’’ connections.
Normally open valve is available as an option.
AO012
AO024
AO230
Adaptor with 12 or 24 VDC, 2/2 cartridge valve,
normally closed and manual override. Standard
DIN 43650 connection or optional “Kostal” or “AMP
junior” connections.
M
G 1/4" THD.x20 M.F.D.
G 1/4" THD.x13 M.F.D.
M10x1.5 6H THD x12 MFD
(4) PLA
CES MARKED "O"
O
O
O
O
MOUNTING PAD "B"
MOUNTING PAD "A"
M6x1 6H THD.x12 M.F.D.
(3) PLA
CES MARKED "N"
N
N
N
T
P
M
P
T
DIAM 6.5
(4) PLACES MARKED "M"
M
M
M
M
90
234022.5
4.5
4.5
14
34 37.5
90
20.3
4
15
26
11.5
22
46
61.5
78.5
The HE series is based on three different
adaptors with two alternative mounting
directions: the smaller He1000 adaptor, the
larger He2000, and the new He2200 High Flow.
The He1000 is designed for use with 80 mm
and 112 mm motors.
Pump sizes: 0.24-2.0 cc/rev.
The He2000 is designed for use with 112
mm, 125 mm and 134 mm motors.
Pump sizes: 0.8-5.7 cc/rev.
The He2200 High Flow is designed for use
with 112 mm, 125 mm and 134 mm mot
ors.
Pump sizes: 0.8-5.7 cc/rev.
With the HE 1000, 2000 and 2200 adaptors,
the unit can be used as a pump motor unit
only, be equipped with directly mounted
or block-mounted cartridge valves or be
equipped with block-mounted Cetop 2 or
Cetop 3 valves.
All adaptors have a check valve, and most
models can be equipped with an integrated
pressure-compensated constant-flow
regulator.
Please note that adaptors are shown from
the pump side on the following pages.
PRESSURE PORT
G 1/4" THD. x13
65
Concentric AB-He1000 He2000 He2200-GB-2011-7
7
A
G 3/8"
B
G 3/8"
50
M
B
T
P
A
A
A
B
A
B
P
T
A
A
P
B
B
T
P
B
T
A
P
B
T
A
P
B
T
A
G 3/8
150
AP000
Adaptor with block for mounting of
1 x Cetop 2 valve.
AR000
Adaptor with block for mounting of
3 x Cetop 2 valve.
AQ000
Adaptor with block for mounting of
2 x Cetop 2 valve.
ADAPTOR He1000
A
G 3/8"
B
G 3/8"
50
A
B
A
B
P
T
A
A
P
B
B
T
M
P
B
T
A
P
B
T
A
G 3/8
100
M
T
P
B
A
B
A
50
G 3/8
A
T
B
P
100
50
Concentric AB-He1000 He2000 He2200-GB-2011-7
8
AA000
Adaptor prepared for block-mounting
of external valves.
O
O
O
O
O
M10x1.5 6H THD x12 MFD
(6) PLACES MARKED "O"
T
P
G 3/8
O
MOUNTING PAD "A"
MOUNTING PAD "B"
84
95
84
95
131
N
N
N
N
M8x1.25-6H THD.x12 M.F.D.
(4) PLACES MARKED "N"
27.7533.34
40.140.1
21.89
24.59
6.02
40.13
12.712.7
17.27
Ø
M
P
T
AS012
AS024
Adaptor with 12 or 24 VDC, cartridge valves,
2/2 normaly closed, 3/2 and 2 x  ow restrictor
valves.
M
A
8 l/min 8 l/min
B
35.8
17.5
A 1/4"
B 1/4"
38
A
A
92
80
176
)
(
)
(
Aux.outlet port G 3/8"
(Normally plugged)
G 3/8"
AF012
AF024
AF230
Adaptor with 12 or 24 VDC, block- mounted
2/2 cartridge valve.
AO012
AO024
AO230
Adaptor with 12 or 24 VDC, 2/2 cartridge valve,
normally closed and manual override. Standard
DIN 43650 connection or optional “Kostal” or “AMP
junior” connections.
M
A
ADAPTOR He2000
M
AE012
AE024
AE230
Adaptor with 12 or 24 VDC, 2/2 cartridge valve,
normally closed. Standard DIN 43650 connection
or optional “Kostal” or “AMP junior” connections.
Normally open valve or manual override is avail-
able
as an option.
G 3/8"
64
Concentric AB-He1000 He2000 He2200-GB-2011-7
9
ADAPTOR He2000
A
G 3/8"
B
G 3/8"
50
M
B
T
P
A
A
A
B
A
B
P
T
A
A
P
B
B
T
P
B
T
A
P
B
T
A
P
B
T
A
G 3/8
150
A
G 3/8"
B
G 3/8"
50
A
B
A
B
P
T
A
A
P
B
B
T
M
P
B
T
A
P
B
T
A
G 3/8
100
AL012
AL024
AL230
Adaptor with 12 or 24 VDC block-
mounted 4/2 cartridge valve.
M
80
G 1/4
G 1/4
G 3/8
100
0
B
A
AN000
Adaptor as pump/motor unit with pressure
and return line port.
G 3/8"
T
M
P
T
Aux.outlet port G 3/8"
(Normally plugged)
G 3/8"
21
AP000
Adaptor with block for mounting of
1 x Cetop 3/NG 6 valve
M
T
P
B
A
B
A
50
G 3/8
A
T
B
P
100
50
AQ000
AR000
Adaptor with block for mounting of
3 x Cetop 3/NG 6 valve
Adaptor with block for mounting of
2 x Cetop 3/NG 6 valve
Concentric AB-He1000 He2000 He2200-GB-2011-7
10
BL000
BL012
BL024
Adaptor with 12 or 24 VDC.
84
95
95
84
M10 (x6)
SECTION A-A
P
R2
R1
G3/8
Ø6,5 (x4)
130
120
120
130
~62
111
19
22
55
82
40
A
A
ADAPTOR He2200 HIGH FLOW
THE NEW He2200 HIGH FLOW ADAPTOR
He2200 High
Flow Adaptor
BF000
BF012
BF024
Adaptor with 12 or 24 VDC, 2/2 cartridge valve,
1 x lowering proportional valve, normally
closed.
BE000
BE012
BE024
Adaptor with 12 or 24 VDC, 2/2 cartridge valve,
normally closed.
The need for more sophisticated systems
at the same envelope size is one of the
elements that is the basis for the He2200
High Flow Adaptor.
Within the envelope size of an He2000,
Concentric has made it possible to
integrate up to 3 cartridge valves for single
acting, 2x single acting or double acting
functions directly into the adaptor without
external manifolds.
Additionally, larger  ow control valves
can be mounted to accept higher return
ows at eg lowering at high speed. The
relief valve can easily be adjusted from the
outside.
In the He2200 high flow version, the
pump and motor are equipped with
splined drive shafts that improve the life of
each, especially at applications with many
starts and stops.
All in all, the He2200 high  ow version
o ers a cost and space e cient solution
and improved performance.
Please note that adaptors are shown
fr
om the pump side on the following
pages.
M
R21RP
BH000
BH012
BH024
Power up/gravity down made for rpm
controlled lifting and proportional lowering.
Adaptor with 12 or 24 VDC, normally closed.
M
R21
RP
M
1R2P1P
82
111
19
22
55
40
A
A
84
95
95
84
P1
P2
R1
SECTION A-A
M10 (x6)
G3/8
Ø6,5 (x4)
120
130
130
120
~71
BM000
BM012
BM024
Power up/gravity down for 2 single acting
functions. Adaptor with 12 or 24 VDC. 3/2
valve for function selection.
M
1R2P1P
55
82
111
19
22
40
A
A
84
84
95
95
R1
M10 (x6)
SECTION A-A
P1
P2
G3/8
Ø6,5 (x4)
120
130
130
120
~83
BG000
BG012
BG024
Adaptor with 12 or 24 VDC, 2x integrated
proportional valve for shunt o function at lift and
lowering, normally closed.
M
R21RP
84
95
95
84
R1
M10 (x6)
SECTION A-A
P
R2
G3/8
Ø6,5 (x4)
130
120
130
120
~50
~62
55
82
111
19
22
40
A
A
55
82
111
19
22
40
A
A
84
95
84
95
M10 (x6)
P2
P1
R1
G3/8
Ø6,5 (x4)
120
130
130
120
~53
M
1R1P P2
Concentric AB-He1000 He2000 He2200-GB-2011-7
11
Q=1.22 cc
Q=0.97 cc
Q=0.84 cc
Q=0.61 cc
Q=0.48 cc
Q=0.24 cc
I=1.22 cc
I=0.97 cc
I=0.84 cc
I=0.61 cc
I=0.48 cc
I=0.24 cc
Q (l/min)
1
0
020406080
2
3
4
5
6
7
I (amp)
20
40
60
80
100
120
140
160
180
200
3.3
p (bar)
100
120 140 160 180 200 220
90
HE PUMPS AND DC MOTORS
The HE series is equipped with motors for
12,24 or 48 VDC. These motors provide
extremely high power output and meet
tough load requirements. A thoughtful
basic design and long-lasting carbon
brushes cut down on maintenance
requirements. All motors are manufactured
by Concentric to ensure maximal system
optimization, performance and quality.
He2000 adaptor can also be equipped
with 
anges for AC-motor mounting.
MAKE THE OPTIMAL CHOICE OF
PUMP AND MOTOR
On the following pages, you will  nd
our range of DC motors and pumps.
Important parameters to consider
in choosing the correct unit are  ow
in l/min, pressure in bars, and duty
cycle. In some cases, allowable amp
consumption is a factor too, due to
restricted battery capacity.
Our curves permit easy com-
parison at a constant voltage
measurement.
How to read the curves:
When pressure and flow are
determined, the amperage can be
read from the pump/motor curve.
The amperage is then transferred
to curve 2.
The amperage corresponds to
an S2 and an S3 value. These values
represent two ways of calculating
duty capability.
S2 is the number of minutes a unit
can operate at a certain workload
before reaching the maximum
allowable temperature. After this,
the unit must cool down until the
motor temperature is less than 2°C
from the ambient tem-perature
before the same S2 value can be
applied again.
S3 is the maximum time in %
per 10 minute period that a unit
can work at a certain pressure/
workload. For example an S3 value
of 30% = 3 min. for each 10 min.
period, over and over again.
Pump motor (Instruction 12 MG32 Ø 80 mm)
Example: 3,3 l/min at 90 bar and 80 amp on pump mot
or curve above
gives S2 = 2,8 min and S3 = 11% at corresponding motor curve below.
S3 (%)
0
5
10
15
20
25
S2 (min)
0
2
4
6
8
10
40 60 100 120 140 160
S2 (min)
S3 (%)
80
3
12.5
I (A)
Corresponding motor
Concentric AB-He1000 He2000 He2200-GB-2011-7
12
p (bar)
50 100 1500 200 250
0.0
0.5
1.0
3.0
4.0
1.5
2.5
3.5
2.0
Q (l/min)
I (amp)
0
5
10
15
20
25
30
35
40
Q=1.75 cc
Q=1.22 cc
Q=0.84 cc
Q=0.48 cc
I=1.75 cc
I=1.52 cc
I=1.22 cc
I=0.97 cc
I=0.84 cc
I=0.61 cc
I=0.48 cc
I=0.24 cc
S2 (min)
10
8
6
0
50
40
30
420
210
0
01020 4030
S3 (%)
S2 (min)
S3 (%)
I (A)
Q=1.52 cc
Q=0.97 cc
Q=0.61 cc
Q=0.24 cc
p (bar)
50 100 1500 200 250
Q (l/min)
I (amp)
0 0.0
0.5
1.0
3.0
1.5
2.5
3.5
2.0
10
20
30
40
50
60
70
Q=1.75 cc
Q=1.52 cc
Q=1.22 cc
Q=0.97 cc
Q=0.61 cc
Q=0.48 cc
I=1.75 cc
I=1.52 cc
I=1.22 cc
I=0.97 cc
I=0.84 cc
I=0.24 cc
I=0.48 c
c
I=0.61 cc
S2 (min)
10
8
6
4
0
50
40
30
20
210
0
02040 8060
S3 (%)
S2 (min)
S3 (%)
I (A)
Q=0.84 cc
Q=0.24 cc
HE PUMPS AND DC MOTORS
24MH82-HE
He1000 MH pump motor 24VDC Ø 84 mm
Viscosity 32 cSt at 40°C. Voltage 24 VDC constant
24MH82-HE-S2 & S3
C
orresponding motor
Code Pump
02 0,24 cc
05 0,50 cc
06 0,60 cc
08 0,80 cc
10 1,00 cc
12 1,25 cc
15 1,50 cc
18 1,75 cc
Code Motor
02 24MH82-HE
Code Motor
01 12MH82HE
Code Pump
02 0,24 cc
05 0,50 cc
06 0,60 cc
08 0,80 cc
10 1,00 cc
12 1,25 cc
15 1,50 cc
18 1,75 cc
12MH82-HE
He1000 MH pump motor 12V DC Ø 84 mm
Viscosity 32 cSt at 40°C. Voltage 12 VDC constant
12MH82-HE-S2 & S3
Corresponding motor
Concentric AB-He1000 He2000 He2200-GB-2011-7
13
0 20 40 60 80 100 120 140 160 180 200 220 p (bar)
S3 (%)
S2 (min)
S3 (%)
S2 (min)
Q (l/min)
0
2
4
6
8
10
I (amp)
0
20
40
60
80
100
120
Q=1.75 cc
Q=1.52 cc
Q=1.22 cc
Q=0.97 cc
Q=0.84 cc
Q=0.61 cc
Q=0.48 cc
I=1.75 cc
I=1.52 cc
I=1.22 cc
I=0.97 cc
I=0.84 cc
I=0.61 cc
I=0.48 cc
I=0.24 cc
10
8
6
0
25
20
15
410
25
0
02040 8060 100 120
I (A)
Q=024 cc
Q (l/min)
0
0 20 40 60 80 100 120 140 160 180 200 220 p (bar)
1
2
3
4
5
6
7
I (amp)
S3 (%)
S2 (min)
0
20
40
60
80
100
120
140
160
180
200
Q=1.22 cc
Q=0.97 cc
Q=0.84 cc
Q=0.61 cc
Q=0.48 cc
Q=0.24 cc
I=1.22 cc
S3 (%)
S2 (min)
I=0.97 cc
I=0.84 cc
I=0.61 cc
I=0.48 cc
I=0.24 cc
10
8
6
4
0
25
20
15
10
25
0
0 20 40 80 100 120 16060 140
I (A)
HE PUMPS AND DC MOTORS
12MG32(T)HE
He1000 MG pump motor 12 VDC Ø 80 mm
Viscosity 32 cSt at 40°C. Voltage 12 VDC constant
12MG32-HE-S2 & S3
C
orresponding motor
Code Pump
02 0,24 cc
05 0,50 cc
06 0,60 cc
08 0,80 cc
10 1,00 cc
12 1,25 cc
Code Motor
10 12MG32-HE
11 12MG32THE
24MG32(T)HE
He1000 MG pump motor 24 VDC Ø 80 mm
Viscosity 32 cSt at 40°C. Voltage 24 VDC constant
24MG32-HE-S2 & S3
C
orresponding motor
Code Pump
02 0,24 cc
05 0,50 cc
06 0,60 cc
08 0,80 cc
10 1,00 cc
12 1,25 cc
15 1,50 cc
18 1,75 cc
Code Motor
15 24MG32-HE
16 24MG32-THE
Concentric AB-He1000 He2000 He2200-GB-2011-7
14
I (A)
180
140
0
8
10
12
6
4
2
100
60
20
0
0 40 80 200 220 P (bar)120 160
Q (l/min)
Q=3.2cc
I=3.2cc
I=1.75cc
I=2.5cc
I=1.5cc
I=1.25cc
I=1.0cc
I=2.0cc
I=0.8cc
I=0.6cc
I=0.5cc
Q=2.5cc
Q=1.75cc
Q=1.25cc
Q=1.5cc
Q=0.8cc
Q=0.6cc
Q=0.5cc
Q=1.0cc
Q=2.0cc
I (A)
0204060
80
100 120 140 160
S2 (min)
0
S3 (%)
0
10
20
30
40
50
10
20
30
40
50
S3 24MD32A-HE
S2 24MD32A-HE
I (A)
200
160
0
8
6
4
2
120
80
40
0
0 40 80 200 220 P (bar)120 160
Q (l/min)
Q=2.0cc
I=2.0cc
I=1.75cc
I=1.5cc
I=1.25cc
I=1.0cc
I=0.8cc
I=0.6cc
I=0.5cc
Q=1.75cc
Q=1.5cc
Q=1.25cc
Q=0.8cc
Q=0.66cc
Q=0.5cc
Q=1.0cc
I (A)
0 50 100 150 200 250
S2 (min)
0
10
20
30
40
50
S3 (%)
0
10
20
30
40
50
S3 12MD32A-HE
S2 12MD32A-HE
HE PUMPS AND DC MOTORS
12MD32(T)HE
He1000/2000 MD pump motor 12 VDC Ø 112 mm
Viscosity 32 cSt at 40°C. Voltage 12 VDC constant
24MD32(T)HE
He1000/2000 MD pump motor 24
VDC Ø 112 mm
Viscosity 32 cSt at 40°C. Voltage 24 VDC constant
Code Pump
02 0,24 cc
05 0,50 cc
06 0,60cc
08 0,80 cc
10 1,00 cc
12 1,25 cc
15 1,50 cc
16 1,60 cc
Code Motor
22 12MD32A
Code Pump
18 1,75 cc
20 2,00 cc
26 2,50 cc
32 3,20 cc
37 3,80 cc
43 4,30 cc
48 4,80 cc
57 5,70 cc
Code Pump
02 0,24 cc
05 0,50 cc
06 0,60 cc
08 0,80 cc
10 1,00 cc
12 1,25 cc
15 1,50 cc
16 1,60 cc
Code Motor
32 24MD32A
Code Pump
18 1,75 cc
20 2,00 cc
26 2,50 cc
32 3,20 cc
37 3,80 cc
43 4,30 cc
48 4,80 cc
57 5,70 cc
24MD32A-S2 & S3
Corresponding motor
12MD32A-S2 & S3
Corresponding motor
Concentric AB-He1000 He2000 He2200-GB-2011-7
15
S2 (min) / S3 (%)
60
50
40
30
20
10
10
10 50 100 150 200 250 300
I (Amps)
S2
(min)
S3 (%)
S3 24MD22THSWA
04020 8060 200 220180 P (bar)120100 160140
I (A)
0 50 100 150 200 250
S2 (min)
0
5
10
15
20
S3 (%)
0
10
20
30
40
Q (l/min)
0
5
10
15
20
25
I (amp)
0
50
100
150
200
250
Q=5,7 cc
Q=4,8 cc
Q=4,3 cc
Q=3,8 cc
Q=3,2 cc
Q=2,5 cc
Q=2,0 cc
Q=1,75 cc
Q=1,2 cc
I=5,7 cc
I=4,8 cc
I=4,3 cc
I=3,8 cc
I=3,2 cc
I=2,5 cc
I=2,0 cc
I=1,6 cc
I=1,2 cc
I=0,8 cc
Q=1,6 cc
Q=0,8 cc
Q=0,48 cc
Q=0,24 cc
I=0,24 cc
I=0,48 cc
I=1,75 cc
S3 24MD22(T)WA
S3 24MD22THSWA
S2 24MD22(T)WA
S2 24MD22THSWA
0 20 40 60 80 100 200 220120 160 160 180
Q (l/min)
0
2
4
6
8
10
12
14
16
18
20
I (amp)
0
50
100
150
200
250
300
p (bar)
Code Pump
02 0,24 cc
05 0,50 cc
06 0,60 cc
08 0,80 cc
10 1,00 cc
12 1,25 cc
15 1,50 cc
16 1,60 cc
Code Motor
20 12MD12WA
21 12MD12TWA
27 12MD12THSWA
12MD12(T)WA-S2 & S3
Corresponding motor
24MD22(T)WA/24MD22THSWA
He1000/2000 MD pump motor 24 VDC Ø 112 mm
Viscosity 32 cSt at 40°C. Voltage 24 VDC constant
24MD22(T)WA/24MD22THSWA
-S2 & S3
C
orresponding motor
Code Pump
02 0,24 cc
05 0,50 cc
06 0,60 cc
08 0,80 cc
10 1,00 cc
12 1,25 cc
15 1,50 cc
16 1,60 cc
Code Motor
25 24MD22WA
26 24MD22TWA
28 24MD22THSWA
Code Pump
18 1,75 cc
20 2,00 cc
26 2,50 cc
32 3,20 cc
37 3,80 cc
43 4,30 cc
48 4,80 cc
57 5,70 cc
Code Pump
18 1,75 cc
20 2,00 cc
26 2,50 cc
32 3,20 cc
37 3,80 cc
43 4,30 cc
48 4,80 cc
57 5,70 cc
HE PUMPS AND DC MOTORS
12MD12(T)WA
He1000/2000 MD pump motor 12 VDC Ø 112 mm
Viscosity 32 cSt at 40°C. Voltage 12 VDC constant
Concentric AB-He1000 He2000 He2200-GB-2011-7
16
P (bar)
Q (l/min )
0
0 50 100 150 200 250
5
10
15
20
25
I (amp)
0
20
40
60
80
100
120
140
160
180
Q=5,7 cc
Q=4,8 cc
Q=4,3 cc
Q=3,8 cc
Q=3,2 cc
Q=2,5 cc
Q=2,0 cc
Q=1,75 cc
Q=1,6 cc
Q=1,52 cc
Q=1,2 cc
Q=0,8 cc
I=5,7 cc
I=4,8 cc
I=4,3 cc
I=3,8 cc
I=3,2 cc
I=2,5 cc
I=2,0 cc
I=1,75 cc
I=1,6 cc
I=1,52 cc
I=1,2 cc
I=0,8 cc
S2 (min)
25
20
15
0
50
40
30
10 20
510
0
0 50 100 200150 250
S3 (%)
S2 (min)
S3 (%)
I (A)
P (bar)
0 50 100 150 200 250
80
60
40
20
0
80
60
40
20
0
0 50 100 200 300150 250
S3 (%)
S2 (min)
S2 (min)
S3 (%)
I (A)
Q (l/min)
0
5
10
15
20
25
I (amp)
0
50
100
150
200
250
300
Q=5,7 cc
Q=4,8 cc
Q=4,3 cc
Q=3,8 cc
Q=3,2 cc
Q=2,5 cc
Q=2,0 cc
Q=1,75 cc
Q=1,6 cc
Q=1,52 cc
Q=1,2 cc
Q=0,8 cc
Q=0,48 cc
Q=0,24 cc
I=5,7 cc
I=4,8 cc
I=4,3 cc
I=3,8 cc
I=3,2 cc
I=2,5 cc
I=2,0 cc
I=1,75 cc
I=1,6 cc
I=1,52 cc
I=1,2 cc
I=0,8 cc
I=0,48 cc
I=0,24 cc
HE PUMPS AND DC MOTORS
12MD12LS(T)WA
He1000/2000 MD pump motor 12 VDC Ø 112 mm
Viscosity 32 cSt at 40°C. Voltage 12 VDC constant
12MD12LS(T)WA-S2 & S3
Corresponding motor
Code Motor
29 12MD12LSTWA
Code Motor
30 24MD22LS(T)WA
24MD22LS(T)WA
He1000/2000 MD pump motor 24 VDC Ø 112 mm
Viscosity 32 cSt at 40°C. Voltage 24 VDC constant
24MD22LS(T)WA-S2 & S3
C
orresponding motor
Code Pump
12 1,2 cc
16 1,6 cc
20 2,0 cc
25 2,5 cc
32 3,2 cc
38 3,8 cc
43 4,3 cc
48 4,8 cc
57 5,7 cc
Code Pump
12 1,2 cc
16 1,6 cc
20 2,0 cc
25 2,5 cc
32 3,2 cc
38 3,8 cc
43 4,3 cc
48 4,8 cc
57 5,7 cc
WQ pumps available.
Concentric AB-He1000 He2000 He2200-GB-2011-7
17
HE PUMPS AND DC MOTORS
P (bar)
S2 (min)
60
50
40
30
0
60
50
40
30
2020
1010
0
100 150 200 250 300
S3 (%)
S2 (min)
S3 (%)
I (A)
Q (l/min
0
0 50 100 200 250150 300
5
10
15
20
25
30
35
I (amp)
0
50
100
150
200
250
Q=5,7 cc
Q=4,8 cc
Q=4,3 cc
Q=3,8 cc
Q=3,2 cc
Q=2,5 cc
Q=2,0 cc
I=5,7 cc
I=4,8 cc
I=4,3 cc I=3,8 cc
I=3,2 cc
I=2,5 cc
I=2,0 cc
0406020 80 200 220
P (bar)
120 140100 160 180
S2 (min)
100
80
60
40
0
100
80
60
40
20 20
0
0 50 100 200 300150 250
S3 (%)
S3=24MA42(T)(H)SWAL
I (A)
Q (l/min
2
4
6
8
10
12
14
16
18
20
22
I (amp)
0
50
100
150
200
250
300
Q=5,7 cc
Q=4,8 cc
Q=4,3 cc
Q=3,8 cc
Q=3,2 cc
Q=2,5 cc
Q=2,0 cc
Q=1,6 cc
Q=1,2 cc
Q=0,8 cc
I=5,7 cc
I=4,8 cc
I=4,3 cc
I=3,8 cc
I=3,2 cc
I=2,5 cc
I=2,0 cc
I=1,6 cc
I=1,2 cc
I=0,8 cc
S2=24MA42(T)WAL
S3=24MA42(T)WAL
S2=24MA42(T)(H)SWAL
Code Motor
31 24MF22S-HWA
24MA42(T)WAL/24MA42(T)(H)SWAL
He2000 MA pump motor 24VDC Ø 125 mm
Viscosity 32 cSt at 40°C. Voltage 24 VDC constant
Code Motor
35 24MA42-HSWAL
36 24MA42THSWAL
45 24MA42-WAL
46 24MA42TWAL
24MA42(T)WAL/24MA42(T)(H)SWAL
-S2 & S3
Corresponding motor
24MF22S-HWAL-S2 & S3
Corresponding motor
Code Pump
12 1,2 cc
16 1,6 cc
20 2,0 cc
25 2,5 cc
32 3,2 cc
38 3,8 cc
43 4,3 cc
48 4,8 cc
57 5,7 cc
Code Pump
20 2,0 cc
25 2,5 cc
32 3,2 cc
38 3,8 cc
43 4,3 cc
48 4,8 cc
57 5,7 cc
24MF22S-HWAL
He2000 MF pump motor 24VDC Ø 130 mm
Viscosity 32 cSt at 40°C. Voltage 24 VDC constant
Concentric AB-He1000 He2000 He2200-GB-2011-7
18
HE PUMPS AND DC MOTORS
He2000 24MD22S-WALX2
He2200 24MD22S-HEX2
He2000 MD pump motor 24VDC Ø 112 mm
n
U
P
S2
S3
E
0
100
200
300
400
n [rpm]
0
2000
4000
6000
8000
U [V]
0
10
20
30
40
P [W]
0
1000
2000
3000
4000
E
0.0
.2
.4
.6
.8
S2[min]
0
10
20
30
40
S3[%]
0
10
20
30
40
I [A]
I
P = power n = speed
E = eciency S2 = continuous (min.)
I = current S3 = intermittent (%)
U = voltage
He2000 24MD22-WALX
He2200 24MD22-HEX
He2000 MD pump motor 24VDC Ø 112 mm
M [Nm] Torque
0123456789101112
0
100
200
300
400
n [rpm]
0
2000
4000
6000
8000
U [V]
0
10
20
30
40
P [W]
0
1000
2000
3000
4000
E
0.0
.2
.4
.6
.8
S3[%]
0
20
40
60
80
S2[min]
0
20
40
60
80
I [A]
n
U
E
I
P
S3
S2
P = power n = speed
E = eciency S2 = continuous (min.)
I = current S3 = intermittent (%)
U = voltage
Code Motor
33 24MD22S-WALX2
28 24MD22S-HEX2
Curve below shows motor performance only.
To size a motor correctly, calculate “hydraulic power”: P(kW) = p(Bar) x Q(L/min) ÷ 600). Look in the diagram and  nd
the
torque M(Nm) and rpm for the calculated power. Then calculate “pump displacement” D(cm3/rpm) for your needed working
pressure p(Bar): D(cm3/rpm) = (M(Nm) x 2π x 10 x 0, 9) ÷ p(bar). From the result, choose the closest, smaller, displacement
of the standard pumps. Then check the  ow Q(L(min) for the chosen pump Q(L/min)=((n/rpm) x D(cm3/rpm)) ÷ 900. From
that reference, check the curves below for motor speed, current draw, S2 and S3 performance. S2 is the number of minutes
a unit can operate at a certain workload before reaching the maximum allowable temperature. The unit must cool down
until the motor temperature is less than 2°C from the ambient temperature before the same S2 value can be applied again.
S3 is the maximum time in % per 10 minute period that a unit can work at a certain pressure/workload. For example, an S3
value of 30% = 3 min. for each 10 min. period, over and over again.
Curve below shows motor performance only.
Code Motor
34 24MD22-WALX
30 24MD22-HEX
Concentric AB-He1000 He2000 He2200-GB-2011-7
19
TECHNICAL INFORMATION
Symbols
Flow Q
Operating p
pressure
Internal diameter, d
hydraulic cylinder
Area of hydraulic A
cylinder
Piston force F
Piston speed V
Power requirement P
for motor
Pump displacement D
Torque requirement M
Equations
Q = 0,06 x V x A
0,1 x A
p =
F
4
A =
∏ x d
2
Max pressure p
1
230 bar
Intermittent p
2
255 bar
N
m/s
kW
START SWITCHES
Dimensional drawing
12/24 VDC start switch
G
G
TYPICAL CIRCUIT
P =
p x Q
600 x
Tot
mm
2
28
55.6
5.5
93.9
57
54
56
5.6
32
58
53
29
M8
93
+
+
Cyl. down
Cyl. up
M
Code Start switch
A None
U 12VDC, MG and MH motor Ø80
V 24VDC, MG and MH motor Ø80
W 12VDC, MD and MA motor Ø112
X 24VDC, MD and MA motor Ø112
G 24VDC, MA motor, Heavy duty Ø125
U
V
W
X
U
V
W
X
Allowable  uids HL or HLP hydraulic oils according
to DIN 51524.
Biogradable  uids eg. Statoil Bio Pa. Before using
other types of  uids, contact factory.
Recomended viscosity 40-16mm
2
/s. Permissible
cold start viscosity is 2000mm
2
/s.
Contact factory before using  uids outside this range.
Temperature min -25
o
C, max +80
o
C.
Fluid cleanliness We recommend a cleanliness
according to IS4406/1986 Code 18/14 or better to
achieve optimal performance and lifetime.
When operating outside these limits, see
recommendations in “Allowable  uids”.
PUMP INFO
Common units
l/min
bar
mm
cm
3
/rev
Nm
M =
D x p
62,8 x
mek
Concentric AB-He1000 He2000 He2200-GB-2011-7
20
TECHNICAL INFORMATION
HE-BOX POWER PACKS
From the well-known and well-reputed Hesselman Classic (made by Concentric) the New HE-Box Power Pack is developed.
The base concept is the HE Power Pack,which, with a box in steel/TPE combination, is a hydraulic unit for easy mounting,
tough conditions, and high serviceability.
Grommets for hydraulic
outlets and el.cables.
454
315
83,50
273,50
5
35
89120
264
141,5035
46
15,5
410
HE POWER PACK
with box 1, 2 or 3 kW
Performance
HE POWER PACK
with box 1 or 2 kW
Performance
Grommets for hydraulic outlets
and el. cables.
Attaching holes M10 (4x)
430
273,50
83,50
35
35 141,50
5
579
540
89120
26446
15,5
Concentric AB-He1000 He2000 He2200-GB-2011-7
21
30
29.5
90
Vertical reservoir
90
137
88
A
113
130
B
152
12 O' CLOCK
6 O' CLOCK
PAD ’’A’’
9 O'CLOCK
3 O'CLOCK
90
90
137
29.5
211
150
84
80Ø
151
112Ø
180
112Ø
155
Ø 116
Ø112
47
66
MH
MG
MD
MD-HS
MD 32
He1000
Dimensional drawing for power unit 12/24 VDC
TECHNICAL INFORMATION
Reservoir, length He1000
Weights, ~kg He1000
Basic version and add-on’s Kg
Standard He1000 80mm 5
Standard He1000 112mm add-on (di 80mm - 112 mm) +3.7
Add-on Cetop block He1000 +0.47/pc
Add-on HE Box 400mm (box + cover) +6.4
Add-on HE Box 520mm (box + cover) +7.5
Basic version incl. plastic reservoir 1 l, 2/2 cartridgevalve,
start solenoid. AC version excl motor and start solenoid.
Weights also excludes oil and are approximate and depending
on version of pumps, reservoirs and valving.
Reservoir Codes Reservoir,
T
ype Horizontal Vertical length
V V (mm)
Cylindrical AA V=0,5 l AB V=0,5 l A=172
C
ylindrical AC V=0,7 l AD V=1,0 l A=249
Rectangular AE V=1,0 l AF V=1,0 l B=129
Rectangular AG V=1,4 l AH V=1,7 l B=164
Rectangular AJ V=2,0 l AK V=2,1 l B=199
Rectangular AL V=3,0 l AM V=3,8 l B=299
(V=Usable volumes in litres)
Concentric AB-He1000 He2000 He2200-GB-2011-7
22
PAD A
260
125
Ø
12 O'CLOCK
6 O'CLOCK
3 O'CLOCK
9 O'CLOCK
178
132
130
M10
228
Ø128
Ø125
Ø133
Ø134
276.7
186
Ø112
Ø116
196
170
164.5
Ø112
168
112
Ø
139,5
Ø
112
174
MD-HS
MD 32
MD
MA
MA-HS
MF
TECHNICAL INFORMATION
He2000 / He2200
Dimensional drawing for power unit 12/24 VDC
MD-HEX
Concentric AB-He1000 He2000 He2200-GB-2011-7
23
40
170Ø
E
D
C
203
188
165
38
124Ø
152
198
55
43
47
66
Vertical reservoir
Vertical reservoir
Reservoir, length He2000
Weights, ~kg He2000
Basic version and add-on’s Kg
Standard He2000 112mm 9.5
Standard He2000 125mm add-on (di 112mm-125mm) +4.8
Standard He2000 AC (add-on Standard-112mm motor 3
+ AC  ange and connector
Add-on Cetop block He2000 +0.7/pc
Add-on HE Box 400mm (box + cover) +6.4
Add-on HE Box 520mm (box + cover) +7.5
Basic version incl. plastic reservoir 1 l, 2/2 cartridgevalve,
start solenoid. AC version excl motor and start solenoid.
Weights also excludes oil and are approximate and depending
on version of pumps, reservoirs and valving.
TECHNICAL INFORMATION
Reservoir Codes Reservoir,
Type Horizontal Vertical length
V V (mm)
124 Plastic Cylindrical BA V=1,0 BB V=0,9 C=143
124 Plastic Cylindrical BC V=1,6 BD V=1,3 C=191
124 Plastic Cylindrical BE V=1,8 BF V=1,8 C=230
124 Steel Cylindrical BG V=1,5 BH V=1,5 D=230
124 Steel Cylindrical BJ V=2,8 BK V=2,9 D=306
170 Steel Cylindrical BL V=3,4 BM V=2,0 D=219
170 Steel Cylindrical BN V=5,6 BO V=4,4 D=328
170 Steel Cylindrical BP V=6,2 BQ V=5,6 D=397
165x203 Steel Rectangular BR V=6,3 BS V=7,0 E=306
165x203 Steel Rectangular BT V=10,6 BU V=12,1 E=471
(V = Usable volume in litres)
Concentric AB-He1000 He2000 He2200-GB-2011-7
24
He1000/He2000/He2200 POWER PACK CODE KEYS
Sect He1000 kit no. HE Box
I Code He1000 Adaptor Size
 )F )FBEBQUPS t
II Code He1000 Coil volt.+ valve type
 "" "EBQUPS,JU  t
 "& 7BMWF,JU7OPSNDMPTFE  t
 "& 7BMWF,JU7OPSNDMPTFE  t
"& 7BMWF,JU7OPSNDMPTFE  t
 "EBQUPS,JU  t
"- 7BMWFLJU7JOCMPDL  t
 "- 7BMWFLJU7JOCMPDL  t
 "- 7BMWFLJU7JOCMPDL  t
 "EBQUPSLJU  t
"/ "EBQUPSLJU  t
 "0 7BMWFLJU7DPEF"&XJUINBOVBMPWFSSJEF  t
 "0 7BMWFLJU7DPEF"&XJUINBOVBMPWFSSJEF  t
 "0 7BMWFLJU7DPEF"&XJUINBOVBMPWFSSJEF  t
 "EBQUPSLJU  t
"1 "EBQUPSLJU  t
 $FUPQCMPDLIFBE  t
 "2 "EBQUPSLJU  t
 $FUPQCMPDLIFBE  t
$FUPQCMPDLQDT  t
AR000 Adaptor kit 1303384
Cetop block, head 1303445
Cetop block, 2 pcs 1303403
III Code He1000 Pump
02 0,24 cm
3
  t
05 0,50 cm
3
 t
06 0,60 cm
3
 t
08 0,80 cm
3
 t
10 1,00 cm
3
 t
12 1,25 cm
3
 t
15 1,50 cm
3
  t
18 1,75 cm
3
  t
20 2,00 cm
3
  t
IV Code He1000 Relief valve
  4FUUJOHCBSFHCBS  t
V Code He1000 Flow control valve
 " /POF t
 & MNJO t
 ' MNJO  t
 , MNJO  t
VI Code He1000 Motor
  .()&NN  t
  .(5)&5IFSNTXNN  t
  .()&NN  t
  .(5)&5IFSNTXNN  t
 .))&NN  t
  .))&NN  t
  .%"NN  t
 .%"NN  t
  .%8"NN  t
  .%58"5IFSNTXNN  t
  .%8"NN  t
  .%58"5IFSNTXNN  t
  .%5)48"XJUIGBONN  t
  .%5)48"XJUIGBONN  t
  .%-458"5IFSNTXNN  t
  .%-458"5IFSNTXNN  t
Sect He1000 kit no. HE Box
VII Code He1000 Reservoir
AA 0,5 l usable, horizontal, cyl., plastic 1303484
AB 0,5 l usable, vertical, cyl., plastic 1303485
AC 0,7 l usable, horizontal, cyl., plastic 1303486
AD 1,0 l usable, vertical, cyl., plastic 1303487
AE 1,0 l usable, horizontal, rect., plastic 1303488
AF 1,0 l usable, vertical, rect., plastic 1303489
AG 1,4 l usable, horizontal, rect., plastic 1303490
AH 1,7 l usable, vertical, rect., plastic 1303491
AJ 2,0 l usable, horizontal, rect., plastic 1303492
AK 2,1 l usable, vertical, rect., plastic 1303493
AL 3,0 l usable, horizontal, rect., plastic 1303494
AM 3,8 l usable, vertical, rect., plastic 1303495
 "/ MVTBCMFSFTFSWPJSLJU)FJOBCPY  t
VIII Code He1000 Motor terminal screw pos.
0 12 o'clock to pad A
3 Terminal bolts at 3 o'clock to pad A
6 Terminal bolts at 6 o'clock to pad A
  5FSNJOBMCPMUTBUPhDMPDLUPQBE" t
IX Code He1000 Start switch
A None
 6 7NNBOENN  t
 7 7NNBOENN  t
 8 7NN  t
 9 7NN  t
X Code He1000 Start switch position
0 12 o'clock to pad A
2 Relative to motor terminal
3 3 o'clock to pad A
6 6 o'clock to pad A
 PhDMPDLUPQBE" t
A No switch
XI Code He1000 Tube kit
"" 5VCFLJUJODMVEFEJOSFTFSWPJSLJU t
XII Code He1000 Breather position
0 12 o'clock to pad A
1 01.30 o'clock to pad A
3 3 o'clock to pad A
4 04.30 o'clock to pad A
 PhDMPDLUPQBE" t
6 6 o'clock to pad A
7 07.30 o'clock to pad A
9 9 o'clock to pad A
XIII Code He1000 Coil/Lever pos on valve
" PhDMPDL5PXBSETNPUPS t
# PhDMPDL5PXBSETDFOUFSPGBEBQUPS t
$ PhDMPDL5PXBSETSFTFSWPJS t
% PhDMPDL"XBZGSPNDFOUFSPGBEBQUPS t
/ /POF t
XIV Code He1000 Access 1
00 No accessories
 )&CPYNN  t
$PWFSUPNNCPY  t
 "TTFNCMFLJU  t
 )&2CPYNN  t
 $PWFSTPVOEBCTPSCFENNCPY  t
 #PYBTTFNCMZLJU t
XV Code He1000 Access 2
00 No accessories
Example of Order Code Structure: He1 - AE024 - 05 - 150 - F - 15 - AD - 6 - C - 2 - AA - 0 - A - 00 - 00
Sect: I II III IV V VI VII VIII IX X XI XII XIII XIV XV
To order a complete unit, simply work
through the options below, creating an
order code as shown in the example.
He1000 POWER PACK CODE KEY
Concentric AB-He1000 He2000 He2200-GB-2011-7
25
Example of Order Code Structure: He2 - AE024 - 43 - 150 - B - 25 - BE - 6 - W - 2 - AA - 0 - A - 00 - 00
Sect: I II III IV V VI VII VIII IX X XI XII XIII XIV XV
Sect He2000 kit no. HE Box
I Code He2000 Adaptor Size
 )F )FBEBQUPS t
II Code He2000 Coil volt.+ valve type
AA000 "EBQUPS,JU  t
AE012 7BMWF,JU7OPSNDMPTFE  t
AE024 7BMWF,JU7OPSNDMPTFE  t
AE230 7BMWF,JU7OPSNDMPTFE  t
"EBQUPS,JU  t
AF012 7BMWF,JU7OPSNDMPTFEJOCMPDL  t
AF024 7BMWF,JU7OPSNDMPTFEJOCMPDL  t
AF230 7BMWF,JU7OPSNDMPTFEJOCMPDL  t
"EBQUPS,JU  t
7BMWFCMPDL,JU  t
AG012 7BMWF,JU7YOPSNDMPTFEJOCMPDL  t
AG024 7BMWF,JU7YOPSNDMPTFEJOCMPDL  t
AG230 7BMWF,JU7YOPSNDMPTFEJOCMPDL  t
"EBQUPS,JU  t
AL012 7BMWFLJU7JOCMPDL  t
AL024 7BMWFLJU7JOCMPDL  t
AL230 7BMWFLJU7JOCMPDL  t
"EBQUPSLJU  t
7BMWFCMPDLLJU  t
AT000 "EBQUPS,JU  t
.BOVBMMZPQFSSFMFBTFWBMWFJOCMPDL  t
AN000 "EBQUPSLJU  t
1PSUQMVHLJU  t
AO012 7BMWFLJU7DPEF"&XJUINBOVBMPWFSSJEF  t
AO024 7BMWFLJU7DPEF"&XJUINBOVBMPWFSSJEF  t
AO230 7BMWFLJU7DPEF"&XJUINBOVBMPWFSSJEF  t
"EBQUPSLJU  t
AP000 "EBQUPSLJU  t
$FUPQCMPDLIFBE  t
AQ000 Adaptor kit 1303404
Cetop block, head 1303427
Cetop block, 1 pcs 1303428
AR000 Adaptor kit 1303404
Cetop block, head 1303429
Cetop block, 2 pcs 1303430
AS012 "EBQUPSLJU  t
7BMWFLJU7BOEJOCMPDL  t
7BMWFCMPDLLJU  t
AS024 "EBQUPSLJU  t
7BMWFLJU7BOEJOCMPDL  t
7BMWFCMPDLLJU  t
III Code He2000 Pump
08 DN
 •
12 DN  t
16 DN  t
20 DN  t
26 DN  t
32 DN  t
38 DN  t
43 DN  t
48 DN  t
57 DN  t
80 DN82  t
81 DN82  t
82 DN82  t
83 DN82  t
84 DN82  t
85 DN82  t
86 DN82  t
87 DN82  t
88
DN82  t
IV C
ode He2000 Relief valve
*** 4FUUJOHCBSFHCBSEJHJUT  t
V Code He2000 Flow control valve
A None
E MNJO  t
K MNJO  t
M MNJO  t
N MNJO  t
R MNJO  t
B MNJO  t
VI Code He2000 Motor
22 .%"NN  t
32 24MD32A Ø 112 mm 1303709 t
20 .%8"NN  t
21 .%58"5IFSNTXNN  t
25 .%8"NN  t
26 .%58"5IFSNTXNN  t
35 24MA42-HSWAL Ø 125 mm fan 1303470
36 24MA42THSWAL (Therm.sw.) Ø 125 mm fan 1303471
 ."8"-NN  t
Sect He2000 kit no. HE Box
VI Code He2000 Motor
27 .%5)48"XJUIGBONN  t
28 .%5)48"XJUIGBONN  t
29 .%-458"5IFSNTXNN  t
30 .%-458"5IFSNTXNN  t
31 24MF22S-HWA Ø 134 mm 1303606
 .%48"-9  t
 .%8"-9  t
50 AC ange B14-71 1303480
51 AC ange B14-80 1303481
52 AC ange B14-90 1303482
53 AC ange B14-100 1303483
VII Code He2000 Reservoir
BA 1,0 l usable, horizontal, cyl., plastic 1303496
BB 0,9 l usable, vertical, cyl., plastic 1303497
BC 1,6 l usable, horizontal, cyl., plastic 1303498
BD 1,3 l usable, vertical, cyl., plastic 1303499
BE 1,8 l usable, horizontal, cyl., plastic 1303500
BF 1,8 l usable, vertical, cyl., plastic 1303501
BG 1,5 l usable, horizontal, cyl., steel 1303502
BH 1,5 l usable, vertical, cyl., steel 1303503
BJ 2,8 l usable, horizontal, cyl., steel 1303504
BK 2,9 l usable, vertical, cyl., steel 1303505
BL 3,4 l usable, horizontal, cyl., steel 1303506
BM 2,0 l usable, vertical, cyl., steel 1303507
BN 5,6 l usable, horizontal, cyl., steel 1303508
BO 4,4 l usable, vertical, cyl., steel 1303509
BP 6,2 l usable, horizontal, cyl., steel 1303510
BQ 5,6 l usable, vertical, cyl., steel 1303511
BR 6,3 l usable, horizontal, rect., steel 1303512
BS 7,0 l usable, vertical, rect., steel 1303513
BT 10,6 l usable, horizontal, rect., steel 1303514
BU 12,1 l usable, vertical, rect., steel 1303515
BV MVTBCMFSFTFSWPJSLJU)FJOBCPY  t
VIII Code He2000 Motor terminal screw pos.
0 12 o'clock to pad A
3 Terminal bolts at 3 o'clock to pad A
6 Terminal bolts at 6 o'clock to pad A
9 5FSNJOBMCPMUTBUPhDMPDLUPQBE" t
IX Code He2000 Start switch
A /POF t
W 7NN  t
X 7NN  t
G 7NNIFBWZEVUZ481-  t
X Code He2000 Start switch position
0 12 o'clock to pad A
2 Relative to motor terminal
3 3 o'clock to pad A
6 6 o'clock to pad A
9 PhDMPDLUPQBE" t
A No switch
XI Code He2000 Tube kit
AA 5VCFLJUJODMVEFEJOSFTFSWPJSLJU t
XII Code He2000 Breather position
0 12 o'clock to pad A
1 PhDMPDLUPQBE" t
3 3 o'clock to pad A
6 6 o'clock to pad A
9 9 o'clock to pad A
XIII Code He2000 Coil/Lever pos on valve
A PhDMPDL5PXBSENPUPS t
B PhDMPDL"XBZGSPNDFOUFSPGBEBQUPS t
C PhDMPDL5PXBSESFTFSWPJS t
D PhDMPDL5PXBSEDFOUFSPGBEBQUPS t
N /POF t
XIV Code He2000 Access 1
00 No accessories
03 Handpump 1303524
28 )&CPYNN  t
28 $PWFSUPNNCPY  t
28 #PYBTTFNCMZLJU  t
29 )&2CPYNN  t
29 $PWFSTPVOEBCTPSCFENNCPY  t
29 #PYBTTFNCMZLJU t
30 )&CPYNNCPY  t
30 $PWFSUPNNCPY  t
30 #PYBTTFNCMZLJU  t
31 )&2CPYNN  t
31 $PWFSTPVOEBCTPSCFENN)FCPY  t
31 Box assembly kit
XV Code He2000 Access 2
00 No accessories
He2000 POWER PACK CODE KEY
Concentric AB-He1000 He2000 He2200-GB-2011-7
26
Example of Order Code Structure: He22 - BE024 - 73 - 150 - K - A - 25 - BA - 3 - W - 6 - AA - 0 - A - 00 - 00
Sect: I II III IV V VI VII VIII IX X XI XII XIII XIV XV XVI
Sect He2200 kit no. HE Box
VIII Code He2200 Reservoir
BA 1,0 l usable, horizontal, cyl., plastic 1303838
BB 0,9 l usable, vertical, cyl., plastic 1303839
BC 1,6 l usable, horizontal, cyl., plastic 1303840
BD 1,3 l usable, vertical, cyl., plastic 1303841
BE 1,8 l usable, horizontal, cyl., plastic 1303842
BF 1,8 l usable, vertical, cyl., plastic 1303843
BG 1,5 l usable, horizontal, cyl., steel 1303844
BH 1,5 l usable, vertical, cyl., steel 1303845
BJ 2,8 l usable, horizontal, cyl., steel 1303846
BK 2,9 l usable, vertical, cyl., steel 1303847
BL 3,4 l usable, horizontal, cyl., steel 1303848
BM 2,0 l usable, vertical, cyl., steel 1303849
BN 5,6 l usable, horizontal, cyl., steel 1303850
BO 4,4 l usable, vertical, cyl., steel 1303851
BP 6,2 l usable, horizontal, cyl., steel 1303852
BQ 5,6 l usable, vertical, cyl., steel 1303853
BR 6,3 l usable, horizontal, rect., steel 1303854
BS 7,0 l usable, vertical, rect., steel 1303855
BT 10,6 l usable, horizontal, rect., steel 1303856
BU 12,1 l usable, vertical, rect., steel 1303857
BV MVTBCMFSFTFSWPJSLJU)FJOBCPY  t
IX Code He2200 Motor terminal screw pos.
0 12 o'clock to pad A
3 Terminal bolts at 3 o'clock to pad A
6 Terminal bolts at 6 o'clock to pad A
9 5FSNJOBMCPMUTBUPhDMPDLUPQBE" t
X Code He2200 Start switch
A /POF t
W 7NN  t
X 7NN  t
G 7NNIFBWZEVUZ481-  t
XI Code He2200 Start switch position
0 12 o'clock to pad A
2 Relative to motor terminal
3 3 o'clock to pad A
6 6 o'clock to pad A
9 PhDMPDLUPQBE" t
A No switch
XII Code He2200 Tube kit
AA 5VCFLJUJODMVEFEJOSFTFSWPJSLJU t
AB Tube kit for adapter codes BA, BE, BF, BG, BH 1303859
XIII Code He2200 Breather position
0 12 o'clock to pad A
1 PhDMPDLUPQBE" t
3 3 o'clock to pad A
6 6 o'clock to pad A
9 9 o'clock to pad A
XIV Code He2200 Coil/Lever pos on valve
A PhDMPDL5PXBSENPUPS t
B PhDMPDL"XBZGSPNDFOUFSPGBEBQUPS t
C PhDMPDL5PXBSESFTFSWPJS t
D PhDMPDL5PXBSEDFOUFSPGBEBQUPS t
N /POF t
XV Code He2200 Access 1
00 No accessories
03 Handpump 1303793
28 )&CPYNN  t
28 $PWFSUPNNCPY  t
28 #PYBTTFNCMZLJU  t
29 )&2CPYNN  t
29 $PWFSTPVOEBCTPSCFENNCPY  t
29 #PYBTTFNCMZLJU t
30 )&CPYNNCPY  t
30 $PWFSUPNNCPY  t
30 #PYBTTFNCMZLJU  t
31 )&2CPYNN  t
31 $PWFSTPVOEBCTPSCFENN)FCPY  t
31 Box assembly kit
XVI Code He2200 Access 2
00 No accessories
Sect He2200 kit no. HE Box
I Code He2200 Adaptor Size
 )F )FBEBQUPS t
II Code He2200 Coil volt.+ valve type
BA000 Adaptor kit 1303786
BE012 Valve kit 12V 2/2 NC 1303386
BE024 Valve kit 24V 2/2 NC 1303387
Adaptor kit 1303756
BF012 Valve kit 12V 2/2 + 2/2 proportional 1303787
BF024 Valve kit 24V 2/2 + 2/2 proportional 1303788
Adaptor kit 1303757
BG012 Valve kit 12V 2x 2/2 proportional 1303789
BG024 Valve kit 24V 2x 2/2 proportional 1303790
Adaptor kit 1303758
BH012 Valve kit 12V 2/2 proportional 1303791
BH024 Valve kit 24V 2/2 proportional 1303792
Adaptor kit 1303759
BL012 Valve kit 12V 4/2 1303392
BL024 Valve kit 24V 4/2 1303393
Adaptor kit 1303760
BM012 Valve kit 12V 2/2 + 3/2 1303704
BM024 Valve kit 24V 2/2 + 3/2 1303705
Adaptor kit 1303761
III Code He2200 Pump
08
DN t
12 DN  t
16 DN  t
20 DN  t
26 DN  t
32 DN  t
38 DN  t
43 DN  t
48 DN  t
57 DN  t
80 DN82  t
81 DN82  t
82 DN82  t
83 DN82  t
84 DN82  t
85 DN82  t
86 DN82  t
87 DN82  t
88 DN82  t
IV Code He2200 Relief valve
*** 4FUUJOHCBSFHCBSEJHJUT  t
V Code He2200 Flow control valve 1 (only applicable in combination
with Adapter code BE, BF and BM)
A /POF t
E MNJO  t
K MNJO  t
M MNJO t
N MNJO t
R MNJO t
B MNJO  t
VI Code He2200 Flow control valve 2 (only appliable in combination with
Adapter code BG, BH and BL)
A /POF t
** Setting 10-35 l/min, eg 12 litres (2 digits)
VII Code He2200 Motor
20 .%)&  t
22 .%)&  t
24 24MA42-HE 1303764 t
26 24MF22S-HE 1303465
 .%4)&9  t
 .%)&9  t
He2200 POWER PACK CODE KEY
Concentric AB-He1000 He2000 He2200-GB-2011-7
27
Readers notes:
Concentric AB-He1000 He2000 He2200-GB-2011-7
Concentric will not accept responsibility for any catalog
errors and reserves the right to modify its products without
prior notice. This also applies to products already ordered,
provided that such modifications can be made without
affecting technical specifications. All trademarks in this
material are properties of their respective owners.
PRODUCT RANGE
HE Powerpacks
12/24/48 VDC 0.3 – 4.5 kW and
0.75 – 3 kW AC modular power packs
HE Box Powerpacks
12/24/48 VDC modular powerpacks
in weatherproof boxes
Pressure Switches
5 - 350 bar, connecting/disconnecting
W100 Hydraulic pumps
0,5 - 2,0 cc 227 bar
W300 Hydraulic pumps
0,8 – 5,7 cc 230 bar
W600 Hydraulic pumps / motors
3 – 12 cc 276 bar
W900 Hydraulic pumps / motors
5 – 31 cc/section 276 bar
Calma The new quiet pumps
6,2 - 23,7 cc/section 250 bar
WQ900 The quiet pumps
5 - 23 cc/section 230 bar
WP900X Hydraulic pumps
16 - 31 cc/section 276 bar
W1500 Hydraulic pumps / motors
19 - 50 cc/section 276 bar
F12 FERRA Heavy duty pumps
16 - 41 cc/section 276 bar
F15 FERRA Heavy duty pumps
19 - 50 cc/section 276 bar
F20/F30 (LS) Hydraulic pumps / motors
23 – 161 cc/section 276 bar
GPA Internal Gear pumps
1,7 – 63 cc/section 100 bar
GC Hydraulic pumps / motors
1,06 – 11,65 cc/section 276 bar
D Hydraulic pumps
3,8 – 22,9 cc/section 207 bar
H Hydraulic pumps
9,8 – 39,4 cc/section 207 bar
II-Stage Hydraulic pumps
4,2 – 22,8 cc/section 276 bar
Rotary Flow Dividers
3,8 – 13,3 cc/section 300 bar
Transmission pumps
www.concentricAB.com
Concentric Rockford Corp.
2222 15th Street
ROCKFORD, IL 61104
USA
Tel: +1-815 398 4400
Fax: +1-815 398 5977
Concentric Skanes AB
Box 95
SE-280 40 SK. FAGERHULT
Sweden
Tel: +46-433 32400
Fax: +46-433 30546
Concentric Hof GmbH
Postfach 1507
D-95014 HOF
Germany
Tel: +49-9281 895-0
Fax: +49-9281 87133
Concentric Suzhou Co. Ltd.
47 Dongjing Industrial Park
9 Dong Fu Lu
SIP, Suzhou
Jiangsu
China 215123
Tel +86 512 8717 5100
Fax +86 512 8717 5101
Concentric is an innovator in
flow control and fluid power, sup-
plying proprietary systems and components for trucks,
buses and industrial vehicles, worldwide. With 1,156
employees and sales of 1,977 million Swedish Kronor,
Concentric AB is listed on the Stockholm Stock Exchange
(www.concentricAB.com).