CB - Counterbalance Valves
Counterbalance Valves Catalog
CB - 10
11141737 • Rev AB • November 2013
OPERATION
APPLICATIONS
SPECIFICATIONS
PERFORMANCE
SCHEMATIC
154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
5
0
73
psi bar
Pressure drop
40L/min
Flow
10.6US gal/min
10
15
20
25
30
145
218
290
363
435
80 120 160 200
21.1 31.7 42.3 52.8
free flow
pilot open
1
2
3
This 3-ported, externally piloted unit is a 12-size cartridge style,
low leakage counterbalance valve with hydraulic vent. The check
section allows free ow from the directional valve (port 2) to the
load (port 1), while normally blocking ow from port 1 to port
2. Reverse ow is blocked until pilot pressure is applied at port 3.
When the load pressure at port 1 rises above the pressure setting,
the integral relief valve is activated and pressure is relieved from
port 1 to port 2.
Rated pressure 350 bar [5075 psi]*
Rated ow at
22 bar (319 psi )
115 l/min [30 US gal/min]
Leakage 10 drops/min @ 70% of
crack pressure
Weight 0.22 kg [0.48 lb]
Pilot ratio 3:1, 4.5:1, 10:1
Cavity CP12-3S
* 350 bar with steel housing
210 bar with aluminum housing
CP441-1
Hydraulic Vent
Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches.
In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual
valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center.
CP441-1
CB - Counterbalance Valves
Counterbalance Valves Catalog
CB - 11
mm [in]
11141737 • Rev AB • November 2013
DIMENSIONS
EXAMPLE CIRCUITS
ORDERING INFORMATION
Load Holding -
Single Actuator
Counterbalance-
Double
Actuator
CP441-1 CP441-1
CP441-1
55.9
[2.20]
41.1
[1.62]
1-1/16-12 UN
turn ccw to increase
pressure setting
turn cw to reduce
pressure setting
1
2
3
h
t
1.25 in
68-75 N
.
m
[50-55 lbf
.
ft]
4mm
Hydraulic Vent
CP441-1
CP448-1CP441-1