4/3 and 4/2 Directional Spool Valves, ISO Size 03
Q
max
= 100l/min,p
max
= 350bar
Two stage, solenoid operated
Series WEVDK…
1/5
Reference: 400-P-181410-EN-02
Issue: 10.2024
S High switching reliability thanks to 2-stage follower
spool operation
S Manifold-mounting design, interface to ISO 4401-03-02
S Operated by switching or proportional solenoids
S Very reliable functions and extremely stable
S With manual override
S All exposed parts with zinc-nickel plating
S High pressure wet-armature solenoids
S The slip-on coil can be rotated and it can be replaced
without opening the hydraulic envelope
1 Description
Series WEVDK ...-6 high performance spool valves are in
ternally piloted and use the follower spool principe. The
main valve components are a cast body, a spring-centered
follower spool assembly and wet armature solenoids with
pressure-tight core tube and slip-on coil. These valves pro
vide reliable service even under the severest operating con
ditions such as very high flow rates, high operating pres
sures, supply voltage drops, long periods without switching,
large and sudden changes in fluid temperature etc. The
highly effective spool actuation method combines the ad
vantages of direct acting and two-stage solenoid valves,
without incurring the well known disadvantages of either
type. The main spool is offset by both the solenoid force and
the P % T *) pressure difference inside the valve. The
greater the P % T pressure difference, the greater the off
setting force. The spool is returned to the mid-position in the
same way, using the P % T pressure difference and without
the need for the usual heavy centering springs. If very low
flow rates, or an open circuit condition, result in there being
no P % T pressure difference, then the spool actuaction re
verts to the normal solenoid / centering spring arrangement.
The manual over-ride, which is fitted as standard equipment
to all valves, can be operated even when high tank line
back-pressures exist in the core tube.
*) The pressure in P must always be equal to, or greater
than, that in T and the valve must be connected in the con
ventional manner i.e. pressure to P, T to tank. All external
parts of the valve are zinc-nickel plated to DIN 50979 and
are thus suitable for use in the harshest operating environ
ments. The slip-on coils can be replaced without opening
the hydraulic envelope and can be positioned at any angle
through 360°.
2 Symbols / Spool types
NOTE! Other spool types on request.
400-P-181410-EN-02/10.2024
Series WEVDK…
2/5
3 Technical data
General characteristics Description, value, unit
Designation 4/3 and 4/2 directional spool valves
Design flange design, pilot operated, electrically operated
Mounting method 4 mounting holes for M5x30 mounting bolts
(valve mounting bolts supplied with the valve)
Tightening torque 5.2 Nm ± 5%
Size size 03 interface to ISO 4401-03-01
Weight - valve with one solenoid
- valve with two solenoids
1.60 kg
2.10kg
Mounting attitude unrestricted
(vertical makes air bleeding difficult)
Hydraulic characteristics Description, value, unit
Maximum operating pressure - ports A, B, P
- port T
350bar
80bar (static)
Maximum flow rate 100 l/min
Flow direction see table “Symbols / Spool types”
Hydraulic fluid HL and HLP mineral oil to DIN 51 524;
for other fluids, please contact BUCHER
Ambient temperature range -30°C … +50°C
Hydraulic fluid temperature range -30°C … +80°C
Viscosity range 10…500mm
2
/s (cSt), recommended 15...250mm
2
/s (cSt)
Minimum fluid cleanliness
Cleanliness class to ISO 4406:1999
class 20/18/15
Electrical characteristics Description, value, unit
Supply voltage 12V DC, 24 V DC, 115 V AC, 230 V AC (40 … 60 Hz)
(Other voltages on request)
Supply voltage tolerance ±10%
Nominal power consumption 12 V DC = 30 W / 24 V DC = 31 W
115 V AC = 32 W / 230 V AC = 31 W
Relative duty cycle 100%
Protection class to ISO20653 / EN60529 IP65 to DIN 40050
Electrical connection 3-pin square plug rotatable 4x90° to DIN 43650 / ISO 4400
400-P-181410-EN-02/10.2024
Series WEVDK…
3/5
4 Performance graphs
measured with oil viscosity 33 mm
2
/s (cSt)
A, C, D, G and H spool
Δp = f (Q) Pressure drop - Flow rate characteristic
0
10
30
20
40
10020
40
60
800
50
p [bar]
P0771.ai
Q [l/min]
2
1
Operated position
Spool type
Flow direction
P % A B % T P % B A % T P % T
Solenoid OFF Solenoid ON Solenoid OFF Solenoid ON
A 2 1 – 2 – 1 –
C 2 1 – 2 – 1 –
D 2 – 1 2 – 1 –
G 2 1 1 2 1 1 –
H 2 1 2 2 1 2 –
IMPORTANT!
The quored max. flow rates apply when symmetri
cal flows pass through the valve.
For non-symmetrical flows, the max. flows are
substantially reduced, in worst cases to only 33%
of the above valves.
Switching times
measured with D spool, at Q = 40 l/min, p = 100 bar
100% voltage, oil temperature +38° C, viscosity 21 cSt.
SWITCHING TIME
ON
[ms]
AUS
[ms]
100… 350 180… 550
Switching times are influenced by flow rate, pressure, vis
cosity, supply voltage and coil temperature.
To achieve switching times which are least influenced by
variations in supply voltage and coil temperature, we rec
ommend the use of our specially developed connector plug,
type LRS (see data sheet 400-P-515101).
5 Installation information
ATTENTION!
Only qualified personnel with mechanical skills
may carry out any maintenance work. Generally,
the only work that should ever be undertaken is to
check, and possibly replace, the seals. When
changing seals, oil or grease the new seals tho
roughly before fitting them.
IMPORTANT!
When fitting the valves, use the specified tighten
ing torque for the mounting bolts. No adjustments
are necessary, since the cartridges are set in the
factory.
400-P-181410-EN-02/10.2024
Series WEVDK…
4/5
6 Dimensions & sectional view
1
2 3
Seal kit NBR no. DS-067
Item Qty. Qty. Description
1 4* 2** O-ring no. 019 ∅ 20,35x1,78 N70
2 4* 4** O-ring no. 012 ∅ 9,25x 1,78 N90
3 –* 1** Cooper ring ∅ 8,00/5,50 x 1,00
DIN7603A
* 4/3 valves (2 solenoids)
** 4/2 valves (1 solenoid), 4/2 valves with detents (2solenoids)
400-P-181410-EN-02/10.2024
Series WEVDK…
5/5
7 Ordering code
8 Related data sheets
Reference (Old no.) Description
400-P-030501 (i-31) Size 03 interface to ISO 4401-03-02
400-P-515101 (P-20) LRSA DIN plug
400-P-120120 Solenoid coil D45/207
E 2024 by Bucher Hydraulics AG Frutigen, CH-3714 Frutigen
www.bucherhydraulics.co
m
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.
Classification: 430.300.-.315.305.300