High performance directional valve, ISO size 05
Q
max
= 160l/min,p
max
= 315bar
Solenoid controlled, 2-stage
Series WEVDE…
1/5
Reference: 300-P-185110-EN-03
Issue: 09.2024
S High switching reliability thanks to 2-stage follower
spool operation
S Unaffected by:
- asymmetric flow path
- long periods under high pressure without switching
- large pressure drops across the spool lands
- low supply voltage
S High flow rates
S Good Dp-Q characteristics
S Pressure in P, A and B to 315 bar
S Wet armature design, change coils without opening
hydraulic envelope
S With manual override
S For subplate mounting, Interface ISO size 05 to
ISO 4401-05-04
1 Description
Series WEVDE ...-10 high performance spool valves are in
ternally piloted and use the follower spool principle. The
main valve components are a cast body, a spring-centered
follower spool assembly and wet armature solenoids with
pressure-tight core tube and slip-on coil. These valves pro
vide reliable service even under the severest operating con
ditions such as very high flow rates, high operating pres
sures, supply voltage drops, long periods without switching,
large and sudden changes in fluid temperature etc. The
highly effective spool actuation method combines the ad
vantages of direct acting and two-stage solenoid valves,
without incurring the well known disadvantages of either
type. The main spool is offset by both the solenoid force and
the P ⇒ T *) pressure difference inside the valve. The
greater the P ⇒ T pressure difference, the greater the offset
ting force. The spool is returned to the mid-position in the
same way, using the P ⇒ T pressure difference and without
the need for the usual heavy centering springs. If very low
flow rates, or an open circuit condition, result in there being
no P ⇒ T pressure difference, then the spool actuaction re
verts to the normal solenoid / centering spring arrangement.
*) The pressure in P must always be equal to, or greater
than, that in T and the valve must be connected in the con
ventional manner i.e. pressure to P, T to tank.
2 Symbols
1
WEVDE-42-A-10 WEVDE-42-AD-10
WEVDE-42-AG-10
WEVDE-42-BD-10
WEVDE-42-BG-10
WEVDE-43-D-10
WEVDE-43-G-10
AB
PT
a
AB
PT
b
AB
PT
a
AB
PT
b
A
B
PT
ba
WEVDE-42-B-10
AB
PT
a
AB
PT
b
AB
PT
ba
WEVDE-42-AH-10 WEVDE-42-BH-10 WEVDE-43-H-10
AB
PT
a
AB
PT
b
AB
PT
ba
2
3
8
9
4/2 FUNCTIONS
4/2 FUNCTIONS
WITH 4/3 SPOOLS
4/2 FUNCTIONS
WITH 4/3 SPOOLS
4/3 FUNCTIONS
Crossover transients
4
12
11
10
5
6
7
NOTE! Other spool types on request.