Directional valve
3-way/2-position
Q
max
= 40 l/min, p
max
= 350 bar
Direct acting, spool type, switching solenoid
Type series: WKDP32G-8U-…
– Screw-in cartridge valve for cavity AU/C1030
– All external parts with zinc-nickel plating according to
DIN EN ISO 19598
– Installation in threaded port body type GAU-12
– Fits common cavity according to ISO and NFPA
– Reliable switching, even after long dwell times
– Low head loss
– Optional with manual override
– The slip-on coil can be rotated, and it can be replaced
without opening the hydraulic envelope
– High pressure wet-armature solenoids
– Various plug-connector systems and voltages are
available
Symbol
13
2
Description
The 3-way/2-position solenoid operated spool valves,
series WKDP32G…, are NG 8, direct acting, pressure
balanced screw-in valves with a 7/8-14 UNF mounting
thread. They are designed on the proven sliding-
spool principle. The straightforward design delivers an
outstanding price/performance ratio. All external parts
of the screw-in valves are zinc-nickel plated and are thus
suitable for use in the harshest operating environments.
The slip-on coils can be replaced without opening the
hydraulic envelope and can be positioned at any angle
through 360°. These valves are primarily used in mobile
and industrial applications as pilot valves for control
ling the travel direction of actuators such as hydraulic
motors and cylinders. For self-assembly, please refer to
the section related data sheets.
Type series: WKDP32G-8U-… 1 / 5 Reference: 400-P-120920-EN-02/04.2024
Technical data
General characteristics Description, value, unit
Function group directional valve
Function 3-way/2-position
Design screw-in cartridge valve
Controls switching solenoid
Characteristic direct acting, spool type
MTTFd value 150 years
Construction size NG 8 / SAE 10
Thread size 7/8-14 UNF-2A
Mounting attitude unrestricted
Weight 0.54 kg
Cavity acc. ISO fits into ISO 17209: 7/8-03-0-13
Cavity acc. NFPA fits into NFPA/T3.5.50: 0.875-03-0-09
Cavity acc. factory standard AU/C1030
Tightening torque steel 80 Nm
Tightening torque aluminium 80 Nm
Tightening torque tolerance ± 10 %
Minimum ambient temperature - 30 °C
Maximum ambient temperature + 50 °C
Surface protection
all external parts with zinc-nickel plating according to
DIN EN ISO 19598
Sealing material see ordering code
Seal kit order number NBR: DS-519-N / FKM: DS-519-V
Hydraulic characteristics Description, value, unit
Maximum operating pressure 350 bar
Maximum flow rate 40 l/min
Flow direction see symbol
Hydraulic fluid
HL and HLP mineral oil according to DIN 51 524;
other fluids on request!
Minimum fluid temperature - 30 °C
Maximum fluid temperature + 80 °C
Viscosity range 10 … 500 mm²/s (cSt)
Recommended viscosity range 15 … 250 mm²/s (cSt)
Minimum fluid cleanliness
(cleanlineless class according to ISO 4406:1999)
class 20/18/15
Type series: WKDP32G-8U-… 2 / 5 Reference: 400-P-120920-EN-02/04.2024
Electric characteristics Description, value, unit
Actuator type solenoid coil
Solenoid coils type 36X48/16.1
Supply voltage DC 12/24 V DC
Supply voltage AC 115/230 (50 … 60 Hz) V AC
Supply voltage tolerance ± 10 %
Nominal power consumption 19 W
Switching time
Switching time measured at: UN: Δp = 280 bar; Q = 32 l/min;
TAmbient = 20 °C; ϑ = 46 mm2/s) / 3 to 2: 21 ms (energizing)
26 ms (de-energizing), 2 to 1: 29 ms (energizing) 25 (de-ener
gizing), 2 to 3: 29 ms (energizing) 38 (de-energizing)
Relative duty cycle 100 %
Electrical connection coil several connection types available, see ordering code
Protection class solenoid coil to ISO 20 653 / EN 60 529
several classes of protection available, see ordering code
(with appropriate mating connector and proper fitting and
sealing)
NOTE!
The switching time can be strongly dependent
on flow rate, pressure, oil viscosity and the dwell
time under pressure. In practice, the switching
time may therefore deviate from the specified
value range.
Performance graphs
measured with oil viscosity 33.0 mm²/s (cSt), coil at steady-state temperature and 10 % undervoltage
p = f (Q) Performance limit Δp = f (Q) Pressure drop-flow rate characteristic
400-PG-0737
p [bar (psi)]
0
0
50 (725)
100 (1450)
150 (2150)
200 (2900)
250 (3600)
300 (4350)
350 (5000)
Q [l/min (gpm)]
4020 3010
(11)(5.25) (8)(2.75)
1)
2)
1) 2 → 1 solenoid de-energized
2) 2 ↔ 3 solenoid energized
400-PG-0736
0
2 (30)
4 (60)
6 (85)
8 (130)
10 (145)
Q [l/min (gpm)]
4020 30100
p [bar (psi)]∆
(11)(5.25) (8)(2.75)
Type series: WKDP32G-8U-… 3 / 5 Reference: 400-P-120920-EN-02/04.2024
Installation
35.5
(1.40)
27
(1.06)
49
(1.93)
41.15
(1.62)
73.5
(2.89)
120.2
(4.73)
46.7
(1.84)
48
(1.89)
12.5
(.492)
Ohne Handnotbetaetigung "O"
without manual override "O"
7/8-14 UNF-2A
1
2
3
MA =
2.7 [Nm]
2.0 [ft·lb]
± 10 %
27
MA = 1)
Ø16.00×2.00
Ø16.00×2.00
Ø19.30×2.20
Ø14.00×1.78
Ø12.42×1.78
Ø12.00×1.45×1.00
Ø12.00×1.45×1.00
Ø10.70×1.45×1.00
Ø10.70×1.45×1.00
12.5
(.492)
37.75
(1.49)
Mit Handnotbetaetigung "P"
with manual override "P"
Mit Handnotbetaetigung schraubbar "S"
with screw-in manual override "S"
Beispiel für die Masseinheit:
Example for the dimensional units:
(.031) =
0.031''
inch
0.79 = 0.79 mm millimeter
NOTE!
1) When fitting the screw-in cartridge valve, use
the specified tightening torque. The value can be
found in the chapter "Technical data".
ATTENTION!
Only qualified personnel with mechanical skills
may carry out any maintenance work. Generally,
the only work that should ever be undertaken is
to check, and possibly replace, the seals. When
changing seals, oil or grease the new seals thor
oughly before fitting them.
NOTE!
The seals are not available individually. The seal
kit order number can be found in the chapter
"Technical data".
Type series: WKDP32G-8U-… 4 / 5 Reference: 400-P-120920-EN-02/04.2024
Ordering code
directional valve
spool-type
24
_
Ex.
1U8PKW D A G
nominal size 8 / SAE 10
W =
K =
8 =
technical design no. (omit when ordering)1 … 9 =
voltage e.g. 24 (24 V)… =
current DCD =
direct actingD =
3-way/2-position, normally closed32G =
electrically operated, V DC = 19 W P =
cavity type AU/C1030U =
32G N DO
with manual override
with screwable manual override
without manual override (standard)
O =
P =
S
=
FKM (fluorocarbon rubber / VITON) seals
(special seals on request)
NBR (nitril-butadien-rubber / BUNA) seals (standard)
N =
V
=
standard model according to valid data sheet
special model (on request)
=
=
A ... Q
Z ... R
Junior Timer radial plug connection (IP 65)
Junior Timer radial plug connection (with protection diode, IP 65)
DIN EN 175301-803 connection, 3-pole 2 P+E, without mating plug (IP65)
(standard)
connection without mating plug
only connection “G“ with mating plug
without
Deutsch plug connection DT04-2P, 2-pole radial (IP 67/69)
for the following plug-variants, please consult BUCHER:
Deutsch plug connection DT04-2P, 2-pole radial (with protection diode, IP 67/69)
DIN EN 175301-803 connection, 3-pole 2 P+E, without mating plug (with protection diode, IP65)
J
=
JR
G =
=
=
Q =
UR
U =
=
GR
=
Related data sheets
Reference Description
400-P-040011 form tools
400-P-040291 cavity AU/C1030
400-P-738121 threaded port body GAU-12-…
400-P-120112 solenoid coil 36X48/16.1
400-P-010101 MTTFd Values for Hydraulic Valves
info.ch@bucherhydraulics.com www.bucherhydraulics.com
© 2026 by Bucher Hydraulics AG Frutigen, 3714 Frutigen, Switzerland
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.
Type series: WKDP32G-8U-… 5 / 5 Reference: 400-P-120920-EN-02/04.2024