Directional valve
2-way/2-position
Q
max
= 40 l/min, p
max
= 315 bar
Direct acting, poppet type, switching solenoid
Type series: W1C_B… (installation shallow)
– Slip-in cartridge valve for cavity AA
– All external parts with zinc-nickel plating according to
DIN EN ISO 19598
– Guided valve spool and poppet
– With bidirectional seat-valve shut-off
– With or without manual override
– As an option, hand lever can be fitted to solenoid
– De-energized closed
– The slip-on coil can be rotated, and it can be replaced
without opening the hydraulic envelope
– High pressure wet-armature solenoids
– Various plug-connector systems and voltages are
available
Symbol
2
1
1
2
Without manual override (standard) With manual override
Description
The 2-way/2-position solenoid operated directional seat
valves, series W1C_B (shallow), are size 6, direct acting,
pressure balanced, push-in valves. They are designed
on the poppet/seat principle and are leak-tight in both
flow directions (bidirectional seat-valve shut-off). The
guide spool has a seal. This version is the mounting
version "shallow" which fits into the cavity AA according
to factory standard. See separate data sheet for the
mounting version "deep". These valves are also avail
able with or without manual override, and with the
option of an additional hand lever. All external parts of
the screw-in valves are zinc-nickel plated and are thus
suitable for use in the harshest operating environments.
The slip-on coils can be replaced without opening the
hydraulic envelope and can be positioned at any angle
through 360°. These valves are predominantly used in
Type series: W1C_B… (installation shallow) 1 / 6 Reference: 400-P-110111-EN-01/03.2023
certain mobile and industrial applications where leak-
tight shut-off functions are crucially important. Exam
ples are where loads, tensions, or clamping forces must
be held without leakage. For self-assembly, please refer
to the section related data sheets.
Technical data
General characteristics Description, value, unit
Function group directional valve
Function 2-way/2-position
Design slip-in cartridge valve
Controls switching solenoid
Characteristic direct acting, poppet type
MTTFd value 150 years
Construction size NG 6
Mounting attitude unrestricted
Weight 0.85 kg
Cavity acc. factory standard AA
Tightening torque steel 5.2 Nm
Tightening torque aluminium 5.2 Nm
Tightening torque tolerance ± 5 %
Minimum ambient temperature - 25 °C
Maximum ambient temperature + 50 °C
Surface protection
all external parts with zinc-nickel plating according to
DIN EN ISO 19598
Sealing material see ordering code
Seal kit order number NBR: DS-095-N / FKM: DS-095-V
IMPORTANT!
The less favorable values from the general,
hydraulic and electrical characteristics determine
the temperature range of the whole valve.
Hydraulic characteristics Description, value, unit
Maximum operating pressure 315 bar
Maximum flow rate 40 l/min
Flow direction see symbol
Hydraulic fluid
HL and HLP mineral oil according to DIN 51 524;
other fluids on request!
Minimum fluid temperature - 25 °C
Maximum fluid temperature + 80 °C
Viscosity range 10 … 500 mm²/s (cSt)
Recommended viscosity range 15 … 250 mm²/s (cSt)
Minimum fluid cleanliness
(cleanlineless class according to ISO 4406:1999)
class 20/18/15
Type series: W1C_B… (installation shallow) 2 / 6 Reference: 400-P-110111-EN-01/03.2023
Electric characteristics Description, value, unit
Actuator type solenoid coil
Solenoid coils type D45/207
Supply voltage DC 12/24 V DC
Supply voltage AC 115/230 (50 … 60 Hz) V AC
Supply voltage tolerance ± 10 %
Nominal power consumption V DC = 30 ... 32 W / V AC = 31 ... 32 W
Switching time 25 ... 170 ms ( energizing), 15 ... 70 ms (de-energizing)
Relative duty cycle 100 %
Electrical connection coil several connection types available, see ordering code
Protection class solenoid coil to ISO 20 653 / EN 60 529
several classes of protection available, see ordering code
(with appropriate mating connector and proper fitting and
sealing)
IMPORTANT!
To ensure the performance data is not compro
mised, it is imperative to use coils D45/207
according to data sheet 400-P-120120.
NOTE!
These times are strongly influenced by fluid
pressure, flow rate and viscosity, as well as by
the dwell time under pressure.
Performance graphs
measured with oil viscosity 33.0 mm²/s (cSt), coil at steady-state temperature and 10 % undervoltage
p = f (Q) Performance limit Δp = f (Q) Pressure drop-flow rate characteristic
400-PG-0415
0
50 (700)
100 (1400)
150 (2100)
200 (2900)
250 (3600)
300 (4300)
350 (5000)
Q [l/min (gpm)]
403020100
p [bar (psi)]
(10)(7.5)(5)(2.5)
400-PG-0416
0
5 (70)
10 (140)
15 (215)
20 (285)
25 (350)
Q [l/min (gpm)]
403020100
p [bar (psi)]∆
(10)(7.5)(5)(2.5)
Type series: W1C_B… (installation shallow) 3 / 6 Reference: 400-P-110111-EN-01/03.2023
Installation
Beispiel für die Masseinheit:
Example for the dimensional units:


LQFK

PP
PLOOLPHWHU
Ohne Handnotbetätigung (Standard)
without manual override (standard)
Mit Handnotbetätigung
with manual override
Ø45
(Ø1.77)
81.6
(3.21)
59.1
(2.33)
□
40
(
□
1.57)
M5
6.5
(.256)
ca. 24.3
(ca. .956)
18
(.708)
57.3
(2.26)
92.9
(3.66)
ca. 117.2
(ca. 4.61)
2
1
0$ 
4
56.5
(2.22)
Handnotbetätigung
manual override
1P
IWຘOE
0$  s
Abmessungen siehe Abbildung links
Dimensions see drawing on the left
Ø20.00×2.00
Ø14.00×1.78
Ø18.72×2.62
Ø15.60×1.78
ATTENTION!
Only qualified personnel with mechanical skills
may carry out any maintenance work. Generally,
the only work that should ever be undertaken is
to check, and possibly replace, the seals. When
changing seals, oil or grease the new seals thor
oughly before fitting them.
NOTE!
1) When fitting the slip-in valves, use the speci
fied tightening torque for the mounting screws.
The value can be found in the chapter "Technical
data".
NOTE!
These valves can also be fitted in the cavity AC
according to factory standard, and in such cases
port 3 then has the same function as port 2.
IMPORTANT!
When replacing an old coil with connection
according to DIN 43650/ISO4400 (with other
Pin setup than according to datasheet 400-
P-120120), the new coil can be mounted in 180°
reversed position so that the existing plug (with
180° earthingPIN) can be connected. This does
not affect the performance data.
Type series: W1C_B… (installation shallow) 4 / 6 Reference: 400-P-110111-EN-01/03.2023
IMPORTANT!
A “de-energized open” function can be created
by using the 3/2 solenoid cartridge valve and the
GADA line-mounting body. In this case, ports 2
and 3 are used. Port 1 is plugged.
IMPORTANT!
Hand levers can only be fitted to valves that have
a manual override.
Hand lever fitted on solenoid (optional)
As an option, these valves are available with an addi
tional hand lever. The hand lever can be fitted on the
solenoid. Two models can be supplied:
“HHB” hand lever with detent feature, and the “HHNB”
hand lever without detent feature.
7)
betätigte Stellung / operated position
Mit Handhebel, rastbar
with hand lever, detentable
+HHB
Mit Handhebel, nicht rastbar
with hand lever, not detentable
+HHNB
Ø 23
(Ø 0.91)
127
4
(0.16)
50.6
111.9
154.2
°
7)
(1.99)
(4.41)
(6.07)
(5)
Beispiel für die Masseinheit:
Example for the dimensional units:


LQFK

PP
PLOOLPHWHU
1
2
1
2
NOTE!
Hand levers can only be fitted to valves that have
a manual override.
Type series: W1C_B… (installation shallow) 5 / 6 Reference: 400-P-110111-EN-01/03.2023
Ordering code
W1 = directional valve, poppet-type, direct acting
1…9 = technical design no. hand lever (omit when ordering)
Ex.
A…Q = standard model according to valid data sheet (standard)
Z…R = special model after consultation
D = current DC
:
C = 2-way/2-position, de-energized closed
A = current AC
-++%
B
 '& %'
D = without manual override, with NBR (BUNA) seals (standard)
I = without manual override, with FKM (VITON) seals
B = with manual override, with NBR (BUNA) seals
G = with manual override, with FKM (VITON) seals
1…9 = technical design no. directional valve (omit when ordering)
(blank) = DIN EN 175301-803 connection, 3-pole 2 P+E with mating plug, IP 65 (standard)
M100 = DIN EN 175301-803 connection, 3-pole 2 P+E
DT = Deutsch plug connection DT04-2P (with protection diode, IP 67/69K)
JT = Junior Timer radial plug connection (with protection diode, IP 65)
F = flying leads (600 mm)
(blank) = without hand lever (standard)
+HHB = with hand lever, detentable
+HHNB = with hand lever, not detentable
… = voltage e.g. 24 (24 V)
mating plug
not supplied
Related data sheets
Reference Description
400-P-040011 form tools
400-P-120120 solenoid coil D45/207
400-P-040101 cavity AA
400-P-730111 threaded port body GABA
400-P-730121 threaded port body GADA
400-P-010101 MTTFd Values for Hydraulic Valves
[email protected] www.bucherhydraulics.com
© 2026 by Bucher Hydraulics AG Frutigen, 3714 Frutigen, Switzerland
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.
Type series: W1C_B… (installation shallow) 6 / 6 Reference: 400-P-110111-EN-01/03.2023