1 / 6 Classification: 4.30.10.70.10
Reference: 170-P-060000-E-03 / 08.15
Check Valves for SAE Flange Ports,
Fit between Port and Flange, O-ring on one Face
Series RVSAE 3/6..., 1000 l/min, 420 bar
Patent No. 38 34 066
180°-inverted installation
Inverted installation normally requires
1 x ZPSAE… insert plate
and 1 x DPSAE… seal plate.
1 General
1.1 Product description
These patented dual-purpose SAE
check valves are centred between the
shafts of the four SAE flange bolts.
This results in a compact, easy-to-
install assembly.
The valves can be used without modi-
fication on both 3000 psi (210 bar)
and 6000 psi (420 bar) SAE flange
ports.
The no-flow direction can be reversed
by inverting the valve.
Seal plates and insert plates are
available as required – see also series
RVSAE3/6DS.... with O-rings on both
faces (Data Sht. 170-P-060100-E).
The valve design is based on a guided
poppet that is hardened and ground.
In the no-flow direction, the valve
closes.
The valves can be used for pressure
relief in the opening direction, but only
to a limited extent (consult Bucher
Hydraulics for such applications).
1.2
dvantages
Virtually leak-free
High pressure rating
Compact construction
The same valve body is used for
3000 psi and 6000 psi ports
Same valve body is used for no-
flow directions A B and B A
Optional orifice for metered flow in
the no-flow direction
2 Main characteristics
Designation SAE check valve
Design guided spherical-poppet design
Mounting method fits between port and flange
Size for SAE ¾“ to 2“ flange ports
Dimensions see Table in section 5, Dimensions
Mounting attitude unrestricted
No-flow direction reversible by inverting the valve (see symbols)
Operating pressure range ...6000 psi (420 bar)
Opening pressure 0.2 … 4 bar
Flow rate, Q max. ...1000 l/min
Fluid HL and HLP hydraulic oils to DIN 51524. Other fluids, contact Bucher Hydraulics
Temperature range -30°C... +80°C
Viscosity range 10 ... 500 mm²/s (cSt)
Min. fluid cleanliness 18/14 to ISO 4406 / CETOP RP70H, 8…9 to NAS 1638
For applications outside these parameters, please contact Bucher Hydraulics.