SPECIFICATIONS
RELIEF VALVE
PILOT OPERATED, SLIDING SPOOL
2026 by Bucher Hydraulics, Inc., 2545 Northwest Parkway, Elgin, Illinois 60124, USA
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense.
The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to
continual improvement, we reserve the right to amend the product specifications contained in this catalogue.
©
RVPS-12
OPERATING PRESSURE: 5,000 psi [350 bar]
PROOF PRESSURE: 10,000 psi [700 bar]
FLOW: 60.0 gpm [227 l/m] nominal. See performance chart.
INTERNAL LEAKAGE: 12 cu.in/min [196 cc/m] @ 85% of crack pressure.
DEFINITION OF CRACK: evident at 0.06 gpm [0.25 lpm]
VALVE HOUSINGS: 2500 psi [175 bar] = Aluminum - Anodized.
5000 psi [350 bar] = Steel - Unplated.
OPERATING TEMPERATURE: -40° to +250° F. [-40° to +120° C.]
OPERATING MEDIA: All general purpose hydraulic fluids such as
MIL-H-5606, SAE-#10, SAE-#20, etc.
INSTALLATION: No restriction.
FILTRATION: 25 microns or better.
SEAL KIT NUMBER: SKN-1222 for Buna "N".
SKV-1222 for Viton.
WEIGHT: 0.63 lb [.25 kg] cartridge only.
VALVE CAVITY: #C1220, See Page 0-013.0.
Reference: 520-P-030330-EN-00/03.2026
FEATURES AND BENEFITS
OPERATIONS
DESCRIPTION
All external carbon steel parts are plated for longer life against the elements.
All cartridge valves are 100% functionally tested.
Valve is available with screw, tamperproof, capped and handknob adjustments.
cartridge valve for accurate and smooth pressure regulation.
This unit is a PILOT OPERATED, BALANCED SLIDING SPOOL, PRESSURE RELIEF,
and reliable operation.
A unique self aligning (floating) cage provides very low hysteresis
Hardened precision fitted spool & cage provides reliable, long life.
Overset protection - pilot spring can not go solid.
Adjustment screw can not be backed out of the valve.
Leakproof screw adjustment.
to a load change in a hydraulic circuit.
This cartridge relief valve offers a smooth transition in response
is present at port 1 to force the pilot poppet from its seat thus
This valve blocks flow from port 1 to port 2 until sufficient pressure
opening the valve.
Pressure in tank port (2) will add to the bias spring setting,
and is limited to 2000 PSI.