1 / 6 Classification: 4.30.30.40.20
Reference: 170-P-051000-E-08 / 08.15
Check Valves, Size 04 ... 40
Spherical Poppet-type, Screw-in Design
Series RKVE ... 360 l/min, 350 bar (500 bar)
1
General
1.1 Product description
Series RKVE units are screw-in check
valves with mounting threads ranging
from G 1/8" to G 1-1/2". For other
thread forms, contact Bucher
Hydraulics.
The cavities are identical to those used
by the RKVG valve (REG-02 cavity only)
and RVE valve (REG-01 & REG-02).
The valves prevent flow in the screw-in
direction (B A). In the opposite
direction, there is a range of opening
pressures from 0.2 to 2 bar.
For opening pressures larger than
2 bar, the RVVE-… longer-body
versions of the valves are available; see
data sheet 170-P-051010-E).
The units are spring-closed spherical
poppet valves with hardened body,
poppet and seat. The properties of the
sealing faces have been enhanced by
mechanical processing.
An external O-ring seals the leakage
path between the valve and cavity wall.
Please note that the two types of cavity
use different O-ring sizes !
Additional exists a variant with a
metalic sealing edge for the cavity type
REG-02 (size 04 to 16).
The valves can be used for pressure
relief in the opening direction, but only
to a limited extent (consult Bucher
Hydraulics for such applications).
1.2
dvantages
Virtually leak-free
High pressure rating
Compact construction
Spring is enclosed
(up to size 16)
Various opening pressures
Damped and undamped models
2 Main characteristics
Designation check valve / non-return valve
Design spherical poppet design
Mounting method screw-in cartridge
Size nominal 4...40 mm. See Table in section 5, Dimensions
Dimensions see Table in section 5, Dimensions
Mounting attitude unrestricted
No-flow direction B A (see symbol)
Operating pressure range ... 350 bar (for 500 bar, contact Bucher Hydraulics)
Opening pressure 0.2 ... 2 bar
Flow rate, Q max. ... 360 l/min
Fluid HL and HLP hydraulic oils to DIN 51524
Temperature range -30°C... +80°C
Viscosity range 10... 500 mm²/s (cSt)
Min. fluid cleanliness 18/14 to ISO 4406 / CETOP RP70H, 8…9 to NAS 1638