Pressure valve
Relief function
Q
max
= 60 l/min, p
max
= 300 bar
pilot operated, spool type, proportional solenoid with emergency override
Type series: DBVSA-1LG…
-
Screw-in cartridge valve
-
For cavity AL
-
All external parts with zinc-nickel plating according to
DIN EN ISO 19598
-
Installation in threaded port body type GALA
-
Damped design
-
Seated pilot stage
-
Fail-safe function
-
Excellent stability over the whole pressure and flow
range
-
High pressure wet-armature solenoids
-
The slip-on coil can be rotated, and it can be replaced
without opening the hydraulic envelope
-
Various plug-connector systems and voltages are
available
Description
The invers proportional pressure-relief valves, series
DBVS_-1LG…, are size 5, pilot-operated, high perform‐
ance screw-in valves with a 3/4-16 UNF-2A mounting
thread. They consist of a spool-type main stage and
a leak-free, poppet-type pilot stage with a falling pres‐
sure/current characteristic. Thanks to the damp ing
of the solenoid armature, these pressure-relief car
tridges exhibit excellent stability over the whole pres‐
sure and flow range. With these proportional pres‐
sure-relief car tridges, the relief pressure is dependent
on the electrical control current and can be contin‐
uously varied. When the solenoid is de-energised
(initial position), the relief pressure is the nominal
pressure of the applicable spring range (failsafe func‐
tion). Any pressure at port 1 is additive to the valve
setting at port 2, therefore port 1 should preferably
be con nected directly to tank. In control mode, the
relief pressure is inversely proportional to the change
in the required value (amplifier output current). To
obtain a reliable pressure setting over the entire
pressure range, the overall pressure range is divided
into different pressure levels. If a proportional sole‐
noid is faulty, for example, the integral manual pres‐
sure setting enables the required pressure to be set
mechanically. These valves are mainly used in certain
mobile and industrial applications to limit the system
pressure. The setting is by means of an adjusting
spindle. The slip-on coils can be replaced without
opening the hydraulic envelope and can be positioned
at any angle through 360°. All external parts of
the screw-in valves are zinc-nickel plated and are
thus suitable for use in the harshest operating envi‐
ronments. For installation and further information,
please refer to the section related data sheets.
Type series: DBVSA-1LG… 1 / 10 Reference: 400-P-586101-EN-01/01.2026
Symbol
1
2
Technical data
General characteristics Description, value, unit
Function group Pressure valve
Function Relief function
Design Screw-in cartridge valve
Controls proportional solenoid with emergency override
Characteristic pilot operated, spool type
Construction size NG 5
Thread size 3/4-16 UNF-2A
Mounting attitude unrestricted (preferably vertical, coil down)
Weight 0.40 kg
Cavity acc. factory standard For cavity AL
Tightening torque steel 40 Nm
Tightening torque aluminium 40 Nm
Tightening torque tolerance ± 10 %
Minimum ambient temperature - 30 °C
Maximum ambient temperature + 50 °C
Surface protection
All external parts with zinc-nickel plating according to
DIN EN ISO 19598
Sealing material see ordering code
Seal kit order number NBR: DS-284-N / FKM: DS-284-V
Hydraulic characteristics Description, value, unit
Maximum operating pressure 300 bar
Restriction of the operating pressure 250 bar ¹)
Maximum flow rate 60 l/min
Flow direction see symbol
Hydraulic fluid
HL and HLP mineral oil according to DIN 51 524;
other fluids on request!
Minimum fluid temperature - 30 °C
Maximum fluid temperature + 70 °C
Viscosity range 15 … 380 mm²/s (cSt)
Recommended viscosity range 20 … 130 mm²/s (cSt)
Minimum fluid cleanliness
(cleanlineless class according to ISO 4406:1999)
class 18/16/13
Type series: DBVSA-1LG… 2 / 10 Reference: 400-P-586101-EN-01/01.2026
Hydraulic characteristics Description, value, unit
Opening pressure …50 / …63 / …100 / …160 / …230 / …300 bar
Internal leakage flow rate
pressure range 050: …0.10 l/min
pressure range 063: …0.10 l/min
pressure range 100: …0.15 l/min
pressure range 160: …0.25 l/min
pressure range 230: …0.36 l/min
pressure range 300: …0.45 l/min
NOTE!
¹) Please note that any tank or return-line pres‐
sures acting at port 1 are additive to the pres‐
sure setting at port 2.
Electric characteristics Description, value, unit
Actuator type solenoid coil
Solenoid coils type D36
Supply voltage DC 12/24 V DC
Supply voltage tolerance ± 10 %
Control current 12 V = 0…1400 mA / 24 V = 0…760 mA
Nominal power consumption 19 W
Relative duty cycle 100 %
Minimum ambient temperature - 30 °C
Maximum ambient temperature + 50 °C
Coil resistance R
Cold value at 20 C°
12 V = 5.8 Ω
24 V = 21 Ω
max. warm value
12 V = 8.6 Ω
24 V = 32 Ω
Recommended PWM frequency 200 Hz
Response sensitivity with PWM < 1 % Iɴ
Reproducibility with PWM < 2 % pɴ
Hysterese with PWM 2…4 % Iɴ
Reversal error with PWM 2…4 % Iɴ
Electrical connection coil several connection types available, see ordering code
Protection class solenoid coil to ISO 20 653 / EN 60 529
several classes of protection available, see ordering code
(with appropriate mating connector and proper fitting and
sealing)
Type series: DBVSA-1LG… 3 / 10 Reference: 400-P-586101-EN-01/01.2026
Performance graphs
measured with oil viscosity 33.0 mm²/s (cSt)
p = f (l) Pressure adjustment p = f (l) Pressure adjustment
400-PG-0173
0
80 (1160)
60 (870)
100 (1450)
40 (580)
20 (290)
I [mA]
0 200
400
400
800
500
1000
600
1200
700
1400
100
200
300
600
p
2
[bar (psi)]
2)2)
3)3)
1)1)
1) p
N
= 50 bar (725 psi)
2) p
N
= 63 bar (915 psi)
3) p
N
= 100 bar (1450 psi)
Q = 5 l/min (1.25 psi)
400-PG-0174
0
200 (2900)
250 (3600)
150 (2150)
300 (4350)
100 (1450)
50 (725)
I [mA]
0 200
400
400
800
500
1000
600
1200
700
1400
100
200
300
600
p
2
[bar (psi)]
3)3)
2)2)
1)1)
1) pN = 160 bar (2300 psi)
2) pN = 230 bar (3350 psi)
3) pN = 300 bar (4350 psi)
Q = 5 l/min (1.25 psi)
p = f (Q) Pressure-flow rate p = f (Q) Pressure-flow rate
400-PG-0175
0
10 (145)
20 (290)
30 (435)
40 (580)
50 (725)
60 (870)
Q [l/min (gpm)]
6020 30 40 50100
p
2
[bar (psi)]
1)
(16)(5.25) (8) (11) (13)(2.75)
p
N
= 50 bar (725 psi)
1) = Einsatzgrenze / Application limit
(p min. / I = max. mA)
400-PG-0176
0
20 (290)
40 (580)
60 (870)
80 (1160)
Q [l/min (gpm)]
60
20 30 40 50100
p
2
[bar (psi)]
1)
(16)(5.25) (8) (11) (13)(2.75)
p
N
= 63 bar (915 psi)
1) = Einsatzgrenze / Application limit
(p min. / I = max. mA)
p = f (Q) Pressure-flow rate p = f (Q) Pressure-flow rate
400-PG-0177
0
20 (290)
40 (580)
60 (870)
80 (1160)
120 (1750)
100 (1450)
140 (2000)
Q [l/min (gpm)]
60
20 30 40 50100
p
2
[bar (psi)]
1)
(16)
(5.25) (8) (11) (13)(2.75)
p
N
= 100 bar (1450 psi)
1) = Einsatzgrenze / Application limit
(p min. / I = max. mA)
400-PG-0178
0
40 (580)
80 (1160)
120 (1750)
160 (2300)
200 (2900)
Q [l/min (gpm)]
60
20 30 40 50100
p
2
[bar (psi)]
1)
(16)
(5.25) (8) (11) (13)(2.75)
p
N
= 160 bar (2300 psi)
1) = Einsatzgrenze / Application limit
(p min. / I = max. mA)
Type series: DBVSA-1LG… 4 / 10 Reference: 400-P-586101-EN-01/01.2026
p = f (Q) Pressure-flow rate p = f (Q) Pressure-flow rate
400-PG-0179
0
40 (580)
80 (1160)
120 (1750)
160 (2300)
200 (2900)
240 (3500)
280 (4000)
Q [l/min (gpm)]
60
20 30 40 50100
p
2
[bar (psi)]
1)
(16)(5.25) (8) (11) (13)(2.75)
p
N
= 230 bar (3350 psi)
1) = Einsatzgrenze / Application limit
(p min. / I = max. mA)
Dimensions and sectional view
⌀36
(
⌀1.42)
54.5
(2.15)
72.5
(2.85)
30.5
(1.20)
107.2
(4.22)
137.7
(5.42)
29
(1.14)
0.79 = 0.79 mm millimeter
(.031) = 0.031" inch
Beispiel für die Masseinheit:
Exampel for the dimensional units:
2
1
Ø12.42×1.78
Ø10.70×1.45×1.00
Ø17.17×1.78
3/4-16 UNF-2A
24
M = 1)
A
M = 2.7 [Nm] ±10%
(2ft-lbs
± 10%)
A
Ø16.00×2.00
Ø16.00×2.00
Type series: DBVSA-1LG… 5 / 10 Reference: 400-P-586101-EN-01/01.2026
Installation information
NOTE!
If necessary, air can be purged from the
proportional pressure-relief valves by using
the integral air-bleed screw. The procedure is
as follows:
1. Remove the protective cap (pos. A)
2. Slacken the air-bleed screw approx. 2 turns.
(pos. B)
3. Switch the pressure-relief cartridge ON/OFF
several times until no more air bubbles
escape.
4. Tighten the air-bleed screw (pos. B) with the
specified tightening torque
5. Fit the protective cap (pos. A)
NOTE!
To achieve the screw-in valve's maximum
performance rating, fit the solenoid coil as
shown (with the plug pins nearest the valve
body).
NOTE!
1) When fitting the screw-in cartridge valve,
use the specified tightening torque. The value
can be found in the chapter "Technical data".
NOTE!
The seals are not available individually. The
seal kit order number can be found in the
chapter "Technical data".
ATTENTION!
To prevent any pressure surges, port 1 must
be routed to tank with the least possible back‐
pressure. Any tank pressure acting at port 1
is additive to the pressure setting at the main
port 2.
ATTENTION!
Only qualified personnel with mechanical skills
may carry out any maintenance work. Gener‐
ally, the only work that should ever be under‐
taken is to check, and possibly replace, the
seals. When changing seals, oil or grease the
new seals thoroughly before fitting them.
Manual pressure setting
These inverse proportional pressure-relief cartridges
are equipped as standard with an integral manual
pressure setting. If a proportional solenoid is faulty,
for example, this ma nual pressure setting enables
the required pressure to be set mechanically. The
manual pressure setting can also be used to make
minor pressure adjustments directly at the system.
Note!
Any changes to the manual pressure setting have a
direct effect on the factory settings.
1. Remove the protective cap
1
.
2. Loosen the lock nut
2
.
3. Unscrew (turn to left) the adjusting spindle
3
until the required pressure is set.
4. Tighten the lock nut
2
to the specified torque.
5. Fit the protective cap
1
.
4
2
M = 1 Nm
A
0.7 ft-lb
±10%
±10%
4
3
13
M = 10 Nm
A
7.4 ft-lb
±10%
±10%
2
1
Type series: DBVSA-1LG… 6 / 10 Reference: 400-P-586101-EN-01/01.2026
Reset to factory settings
To reset the proportional pressure-relief cartridges to
their initial position (the factory setting), a constant
flow rate and a pressure gauge that measures the
pressure in the main port A are needed. The pressure
setting must not exceed the nominal pressure of the
spring range in use. The procedure is as follows:
1. Ensure that the solenoid coil is de-energized.
2. Remove the protective cap
1
.
3. Loosen the lock nut
2
.
4. Unscrew the adjusting spindle
3
to its end-stop.
5. screw in the adjusting spindle
3
until the pres‐
sure on the gauge reaches the nominal pressure
(pN) of the spring range in use.
6. Tighten the lock nut
2
to the specified torque.
7. Fit the protective cap
1
.
4
2
M = 1 Nm
A
0.7 ft-lb
±10%
±10%
4
3
13
M = 10 Nm
A
7.4 ft-lb
±10%
±10%
2
1
Air-bleeding
If necessary, air can be purged from these propor‐
tional pressure-reducing cartridges by using the inte‐
gral air-bleed screw. If the cartridge is mounted as
preferred (solenoid coil hanging), the valve behaves
as self-venting. To vent the valve, follow these steps:
1. Remove the protective cap
1
.
2. Loosen the air-bleed screw
4
approx. 2 turns.
3. Switch the pressure-relief cartridge ON/OFF
several times until no more air bubbles escape.
4. Tighten the air-bleed screw
4
to the specified
torque.
5. Fit the protective cap
1
.
4
2
M = 1 Nm
A
0.7 ft-lb
±10%
±10%
4
3
13
M = 10 Nm
A
7.4 ft-lb
±10%
±10%
2
1
Type series: DBVSA-1LG… 7 / 10 Reference: 400-P-586101-EN-01/01.2026
Application example
The application example shows a reversible fan drive.
V1
WK42A…
2
3
1
4
2
1
Type series: DBVSA-1LG… 8 / 10 Reference: 400-P-586101-EN-01/01.2026
Ordering code
Ex.
V =
pilot operated
1 =
pressure relief with internal spring space relief
5 =
nominal size 5
L =
cavity type DC
N =
NBR (nitril-butadien-rubber / BUNA) seals (standard)
V =
FKM (fluorocarbon rubber / VITON) seals
(special seals on request)
A ...
Q = standard model according to valid data sheet
Z ... R
= special model (on request)
1 ... 9
= technical design no. (omit by ordering)
D =
pressure-control valve
IMPORTANT!
Not every combination of voltage values, current type and plug connections vailable.
mating plug
not supplied
(blank) = DIN EN 175301-803 connection 3-pole 2 P+E (standard) (IP 65) with mating plug
T = DIN EN 175301-803 connection 3-pole 2 P+E, with protection diode (IP 65) with mating plug
M100 = DIN EN 175301-803 connection 3-pole 2 P+E (IP 65)
J = Junior Timer plug connection 2-pole radial (IP 65)
JT = Junior Timer plug connection 2-pole radial, with protection diode (IP 65)
I = Junior Timer plug connection 2-pole axial (IP 65)
IT = Junior Timer plug connection 2-pole axial, with protection diode (IP 65)
D = Deutsch plug connection DT04-2P 2-pole 45° (IP 67/69K)
DT = Deutsch plug connection DT04-2P 2-pole 45°, with protection diode (IP 67/69K)
other plug-variants, please consult BUCHER.
… =
voltage e.g. 24 (24 V)
D =
current DC
B =
pressure relief valve
S =
electrically operated, D36, 8 W, proportional
G =
proportional solenoid, inverse type (pulling)
050 =
pressure range …50 bar / …725 psi
063 =
pressure range …63 bar / …915 psi
100 =
pressure range …100 bar / …1450 psi
160 =
pressure range …160 bar / …2300 psi
230 =
pressure range …230 bar / …3350 psi
300 =
pressure range …300 bar / …4350 psi
300
24
-
-
-
-
D
B V S A 1 L G
3
D
N
_
D
5
Related data sheets
Reference Description
400-P-040011 Form tools
400-P-040171 Cavity AL
400-P-720101 Threaded port body GALA
400-P-120110 Solenoid coil D36
Type series: DBVSA-1LG… 9 / 10 Reference: 400-P-586101-EN-01/01.2026
[email protected] www.bucherhydraulics.com
© 2026 by Bucher Hydraulics AG Frutigen, 3714 Frutigen, Switzerland
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.
Type series: DBVSA-1LG… 10 / 10 Reference: 400-P-586101-EN-01/01.2026