200-P-991230-EN-05/04.2020
AP212
8/60
1.5 Suction
The absolute suction pressure must be P
in
0.75 bar
(11 PSI); therefore, the following conditions must be
avoided:
- large height differences between pump and tank
- long stretches of piping
- special features such as:
- bends
- reductions in diameter
- quick couplings
- etc.
It is also advisable to choose a filter of a suitable size to
minimise any pressure drop and to take measures to pre
vent gradual clogging over time.
(Example 1)
In certain cases, the suction pressure can exceed 1 bar
(14.3 PSI), or atmospheric pressure.
Please contact our Sales Department, solution for
P
in
3.5 bar (50 PSI) , are available.
If in a particular application the P
in
pressure is higher than
the recommended value, contact our Sales Office.
The diameter of the suction pipe should ensure that the oil
speed will fall within the range: v = 0.6 - 1.2 m/s.
(Example 2)
M
M
(Example 1)
(Example 2)
P
out
P
in
P
out
P
in
1.6 General precaution
In addition to the recommendations regarding fluids, filtra
tion, coupling, etc., we suggest the following:
- Always check the rotation direction of the pump's
drive shaft; it must be compatible with the rotation
direction of the pump itself.
- Be particularly careful in cleaning and make sure,
when connecting the suction and pressure piping,
that no chips, rag threads, teflon tape, etc. get into the
pump circulation system.
- Check the tightness of the suction and pressure fit
tings, the correct positioning of the O-Ring, and make
sure there is no dirt between the flange and the pump
body.
- The first pump start-up can be facilitated by manually
filling the suction piping and the pump itself with oil.
To facilitate air bleeding, start the pump with the cir
cuit not pressurised.
- To ensure the best heat distribution inside the tank,
make sure the return pipe is not too close to the
pump's suction piping. The pipings themselves
should be below oil tank level to prevent the forma
tion of foam.
- Do not subject the pumps to operating conditions
different from those indicated on section 1.3 ; for
extreme operations, always contact our Technical
Department.
- Never use fluids different from those indicated in sec
tion 1.3 and do not use fluids incompatible with the
pump seals (i.e. HNBR)
- In the event of pump painting, do not use solvents or
paints that are incompatible with the material of the
seals. Do not bake paint with excessively high tem
peratures. Do not paint over the product identification
plate.
1.6.1 Directives and standards
Atex
Attention: The equipment and protective systems
of these catalogue ARE NOT intended for use in
potentially explosive atmospheres.
Ref.: the Directive 99/92/EC and Directive
2014/34/EU.
- ISO 9001:2015 / ISO 14001:2015
Bucher Hydraulics S.p.A. is certified for research,
development and production of directional control valves,
gear pumps and motors, power units, electro pumps,
cartridge valves and integrated manifolds for hydraulic
applications.