1/26
Reference: 200-P-991218-EN-05
Issue: 09.2015
Gear Pumps - AP05
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
2/26
Contents Page
1 General
information 3
.................................................................
1.1 Introduction
to
the
product 3
......................................................
1.2 Non-standard
symbols
used
in
the
text 4
...........................................
2 Technical
information 4
................................................................
2.1 Identifying
the
rotation
direction 4
.................................................
2.2 Recommended
fluids/Allowed
temperatures 5
......................................
2.3 Suction 5
......................................................................
2.4 Filtration 5
.....................................................................
2.5 Motor-pump
coupling 6
..........................................................
2.6 General
precaution 7
............................................................
2.7 Pressure 7
.....................................................................
2.8 Calculating
the
specification
of
a
gear
pump 8
......................................
2.9 Diagrams 9
....................................................................
3 Gear
pump
group
AP05 11
..............................................................
3.1 Pumps
seal
kit
NBR
standard
type 24
...............................................
4 Composition
of
product
code 24
..........................................................
4.1 Single
pumps 24
.................................................................
4.2 Product
identification
plate 24
......................................................
4.3 Single
pump
weight 24
............................................................
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
3/26
1 General information
1.1 Introduction to the product
Gear pumps are widely used in modern hydraulic systems
due to their high performance, long service life and low pur
chase and maintenance costs.
Product development has made it possible to achieve high
operating pressures, excellent volumetric and mechanical
efficiency, and lower noise levels, in operation, by means of:
- meticulous CAD design of the gear teeth and balan
cing areas
- an exacting choice of high-performance materials
- carefully controlled heat treatments
- increasingly tight coupling tolerances, and a high
standard of surface finish.
Bucher Hydraulics S.p.A. has achieved these results by
constantly improving its design, control, and manufacturing
techniques in line with the latest technological develop
ments, while simultaneously introducing a Quality Control
System which ensures that every single product offers the
same high standards.
Product description
B - B
3
6
2
5
4
1
7
10
8
9
B
B
A
A
A - A
1. Drive gear
2. Driven gear
3. Balancing
4. Pump body
5. Front cover
6. Rear cover
7. Mounting tie rod
8. Balancing seal
9. Oil seal
10. Shaft seal
Referring to the pump shown in the figure, the drive gear (1)
drives round the driven gear (2), transferring the oil from the
suction port to the pressure port as it turns round.
The gears are made from high strength steel alloy.
The bushings (3) serve a dual purpose:
- to act as a bearing for the gears
- to balance axial and radial thrust in proportion to the
change in operating pressure.
The gears-bushings assembly is fitted inside the pump
body (4), in which generally the suction and pressure ports
are formed.
The pump body is made of high strength extruded alumi
nium alloy.
The front cover (5), which also acts as a mounting flange,
and the rear cover (6) are connected to one another by
mounting tie rods (7).
The pump assembly is completed by a series of seals:
- Balancing seals (8) can be fitted in recesses in the
bushings as shown in the figure, or in the covers.
Their purpose is to delimit the longitudinal balancing
area separating the suction and pressure zones.
- Oil seals (9) prevent oil from leaking out.
- An oil retaining ring with the dual purpose of preven
ting oil leaks from the drive gear shaft and preventing
dust or other pollutants from entering the pump itself.
Unless otherwise specified, the seals are in nitrilic
compound offering high mechanical strength and
heat resistance.
- Viton seals are available on request.
(see 2.2 Recommended fluids/Allowed temperatures).
Versions available
The Bucher Hydraulics S.p.A. product range includes sin
gle pumps of groups 05-100-200-300 (corresponding to the
common group denominations: 05-1-2-3) and several com
binations of double pumps, triple pumps, and so on, that can
be assembled together according to versions of displace
ment, flanging, and auxiliary valves indicated in this catalo
gue.
Bucher Hydraulics S.p.A. will examine any request for spe
cial versions, features, and customisations not shown in
this catalogue.
To make such a request, please contact our Sales Depart
ment.
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
4/26
1.2 Non-standard symbols used in the text
Check nut
Hexagonal-head
screw ( TE screw)
O-Ring
Lock washer
Socket head screw
(TCE screw)
Woodruff key
11
Dynamometric
spanners
Version with front
and rear cover in
cast iron, available
Square key
4
2 Technical information
2.1 Identifying the rotation direction
The rotation direction of a gear pump is identified by looking
at the pump from the front and with the drive gear turned up
wards (see figures below).
Pumps with clockwise rotation (D) have a drive gear which
turns clockwise, with the suction port on the left and the
pressure port on the right.
Pumps with counterclockwise rotation (S) have a drive gear
which turns counterclockwise, with the suction port on the
right and the pressure port on the left.
The figure also shows the pressure flow inside the pumps
as the oil is transferred from the suction port to the pressure
port.
As regards reversible pumps (R), the ports are alternatively
for suction and pressure.
Pumps with a unidirectional rotation (D or S) have the de
nomination AP.
Pumps with reversible rotation have the denomination
APR.
It is possible to change the rotation direction of the entire
range of pumps without having to replace any component,
except for the AP100 group, for which it is necessary to re
place the front cover.
To ensure a good technical result, we recommend in any
case that such inversion be carried out at our factory.
Technical descriptions are available on request, which
show the correct procedure for the pump rotation inversion.
Right-hand rotation
Left-hand rotation
P
P
Reversible rotation
Suction
Pressure
Pressure
Suction
Pressure
Pressure
Suction
Suction
Pressure behavior
Pressure behavior
Pressure behavior
D
D
S
S
R
R
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
5/26
2.2 Recommended fluids/Allowed temperatures
We recommend using only mineral oil-based hydraulic
fluids that comply with the ISO/DIN standards.
Viscosity range:
recommended 20 ÷ 120 mm
2
/s (cSt)
permitted up to 700 mm
2
/s (cSt)
Operating temperature
Type of
seals
Temperature
AP05-APR05
Buna N -15 ÷ 65 °C
Viton* -10 ÷ 80 °C
Attention: Use of pumps at temperatures above
80°C must always be agreed upon with our Tech
nical Office, and in any case this can cause a sig
nificant worsening in the volumetric efficiency. For
use under conditions different from those indic
ated in this catalogue, please contact our Sales
Department
2.3 Suction
The absolute suction pressure must be P
in
0.75 bar
(11 PSI); therefore, the following must be avoided:
- large height differences between pump and tank
- long stretches of piping
- special features such as:
- bends
- reductions in diameter
- quick couplings
- etc.
It is also advisable to choose a filter of a suitable size to min
imise any pressure drop and to take measures to prevent
gradual clogging over time.
(Example 1)
In certain cases, the suction pressure can exceed 1 bar
(14.3 PSI), or atmospheric pressure.
Please contact our Sales Department, solution for
P
in
3.5 bar (50 PSI) , are available.
If in a particular application the P
in
pressure is higher than
the recommended value, contact our Sales Office.
The diameter of the suction pipe should ensure that the oil
speed will fall within the range: v = 0.6 - 1.2 m/s.
(Example 2)
M
M
(Example 1)
(Example 2)
P
out
P
in
P
out
P
in
2.4 Filtration
A short service life of a gear pump is normally due to the
presence of impurities in the oil.
It is therefore essential to have an effective filter in the sys
tem and to carry out regular maintenance to ensure a long,
trouble-free service life.
When possible and compatible with the hydraulic circuit in
stalled, Bucher Hydraulics S.p.A. recommends that the sys
tem have total filtration (suction, pressure, return).
In any case, the filtering system must constantly ensure an
oil contamination class equal to or less than those shown in
the following table.
Operating
pressure
> 170 bar
2430 PSI
< 170 bar
2430 PSI
Contamination
class NAS 1638
9 10
Contamination
class ISO 4406
18/15 19/16
Obtain wit filter
βx= 75
20 25
We also recommend that an adequate air filter be installed
on the tank to prevent contaminating substances such as
dust, sand, etc. from getting into the oil, as these substan
ces can enter the tank through the air flow caused by the le
vel variations in the tank itself.
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
6/26
2.5 Motor-pump coupling
M
M
:
H
h
2.5 − 3.5
Absolutely no radial or axial forces should be transmitted to
the drive shaft in the motor-pump coupling.
Such forces cause rapid and irregular wear on the balan
cing surface of the bushings and gear support, with a con
sequent worsening in pump performance.
The coupling joint must be able to absorb any discrepancies
in the coaxial alignment of the motor-pump shafts without
placing any load on the pump shaft.
In the couplings between splined shafts, the connecting
sleeve must be free to move along its axis.
The length of the sleeve must be sufficient to cover the
splined sections of the motor-pump shafts completely in
any position.
The distance between the ends of the shafts must be
between 2.5 ÷ 3.5 mm (.10” ÷ .14”).
Make sure that the splined coupling is suitably lubricated to
protect it against rapid deterioration.
If there are radial and/or axial loads on the drive shaft, such
as when it is driven by a V-belt and pulley or pair of gear
wheels, it should be fitted with a front cover with supporting
bearings.
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
7/26
2.6 General precaution
In addition to the recommendations regarding fluids, filtra
tion, coupling, etc., we suggest the following:
- Always check the rotation direction of the pump's
drive shaft; it must be compatible with the rotation dir
ection of the pump itself.
- Be particularly careful in cleaning and make sure,
when connecting the suction and pressure piping,
that no chips, rag threads, teflon tape, etc. get into the
pump circulation system.
- Check the tightness of the suction and pressure fit
tings, the correct positioning of the O-Ring, and make
sure there is no dirt between the flange and the pump
body.
- The first pump start-up can be facilitated by manually
filling the suction piping and the pump itself with oil.
To facilitate air bleeding, start the pump with the cir
cuit not pressurised.
- To ensure the best heat distribution inside the tank,
make sure the return pipe is not too close to the
pump's suction piping. The pipings themselves
should be below oil tank level to prevent the forma
tion of foam.
- Do not subject the pumps to operating conditions dif
ferent from those indicated in section 2.8 ; for ex
treme operations, always contact our Technical De
partment.
- Never use fluids different from those indicated in sec
tion 2.2.
- In the event of pump painting, do not use solvents or
paints that are incompatible with the material of the
seals. Do not bake paint with excessively high tem
peratures. Do not paint over the product identification
plate; the warranty will not be valid if this plate is il
legible.
2.6.1 Directives and standards
Atex
Attention: The equipment and protective systems
of these catalogue ARE NOT intended for use in
potentially explosive atmospheres that is to say
where there is an explosive atmosphere referred
to in Article 2 of the Directive 99/92/EC and re
ferred to Article 1.3 of the Directive 94/9/EC
Machinery safety
Hydraulic pumps are excluded by Directive 2006/42/EC
- ISO 9001: 2008 / ISO 14001:2004
Bucher Hydraulics S.p.A. is certified for research,
development and production of directional control valves,
gear pumps and motors, power units, electro pumps,
cartridge valves and integrated manifolds for hydraulic
applications.
2.7 Pressure
Pressure levels:
P1 = continuous pressure
P2 = intermittent pressure
P3 = peak pressure
The recommended oil speed in the pressure pipes is:
v = 2 to 5 m/s
The characteristic data of each pump is given in the tables
on the following pages.
P1
P2
P3
t (s)
p (bar)
max. 5 s
p0.05 s
AP05
APR05
Pressure flow rate surging
Pump z DQ%
AP05 - APR05 13 13
t (s)
Q (l/min)
Q%
Q%=
Qmax.- Qmin.
Qmax.
100
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
8/26
2.8 Calculating the specification of a gear pump
The following parameters are defined:
Vc = (cm3/r) pump displacement;
n = (r/min) no. of rpms of the drive shaft;
Q = (l/min) flow rate;
p = (bar) operating pressure;
T = (Nm) drive torque;
N = (kW) power;
η
v
= (%) volumetric efficiency;
η
m
= (%) mechanical efficiency;
η
t
= (%) total efficiency
M
p
n
T
Q
N (T,n)
Vc
N =
100000
η
v
η
m
Vc · n
p · Vc
Q · p
6.12 ·
η
t
Q =
T = 1.59
Example
AP05/0.9 Vc= 0.9 cm
3
/r n= 1500 r/min p=200 bar η
v
= 94% η
m
= 90% η
t
= 84.6%
100000
0.9 · 1500
Q =
94= 1.27 l/min.
N =
1.27 · 200
6.12 · 84.6
= 0.49 kW
90
= 3.18 Nm
200 · 0.9
T
= 1.59
Important: Please contact our Sales Department if even one of the operating limits indicated in the tables below
(temperature, pressure, rpm) is exceeded, as well as in the case of two or more maximum values at the same time,
or for applications with particularly heavy-duty cycles.
AP/APR05 Displacement Max. pressure n.min.
Type cm
3
/rev Cu.In.P.R.
P1 P2 P3
P< 100 P > 100 n.max.
bar P.S.I. bar P.S.I. bar P.S.I. bar bar
AP05/0.25 0.25 .015 170 2400 180 2600 200 2900 800 3000 7000
AP05/0.5 0.5 .030 190 2700 210 3000 230 3300 650 3000 7000
AP05/0.75 0.75 .045 190 2700 210 3000 230 3300 650 1500 7000
AP05/0.9 0.9 .055 190 2700 210 3000 230 3300 650 1500 7000
AP05/1.2 1.2 .073 170 2400 180 2600 200 2900 550 1500 6000
AP05/1.6 1.6 .097 170 2400 180 2600 200 2900 550 1500 6000
AP05/2.3 2.3 .139 150 2150 160 2300 180 2600 550 1500 4500
APR05/0.25 0.25 .015 150 2200 160 2300 180 2600 800 3000 7000
APR05/0.5 0.5 .030 170 2400 190 2700 210 3000 650 3000 7000
APR05/0.75 0.75 .045 170 2400 190 2700 210 3000 650 1500 7000
APR0.5/0.9 0.9 .055 170 2400 190 2700 210 3000 650 1500 7000
APR05/1.2 1.2 .073 150 2200 160 2300 180 2600 550 1500 6000
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
9/26
2.9 Diagrams
Oil viscosity: 37 mm
2
/s
Oil temperature: 40° C
1.6
a
b
b = 190 bar
a = 30 bar
AP05
b
b
0.9
b
b
a
a
a
a
b
a
1.2
0.75
0.5
0.25
6
5
4
3
2
1
20001000 3000 4000 5000 60000
n (min )
Q (l/min)
-1
0.30
1.6
1.6
p (bar)
200150100500
N (kW)
0.05
0.10
0.15
0.20
0.25
0.25
0.5
0.75
0.9
1.2
p (bar)
200150100500
T (Nm)
0.25
0.5
0.75
0.9
1.2
4.50
0.75
1.50
2.25
3.00
3.75
n= 1000 (min
-1
)
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
10/26
1.6
1.6
3.0
0.90
1.6 1.6
1.2
0.25
p (bar)
200150100500
N (kW)
0.25
0.5
0.75
0.9
1.2
p (bar)
200150100500
N (kW)
0.15
0.30
0.45
0.60
0.75
0.25
0.5
0.75
0.9
1.2
p (bar)
200150100500
N (kW)
0.25
0.5
0.75
0.9
1.2
p (bar)
200150100500
N (kW)
0.5
1.0
1.5
2.0
2.5
0.5
0.75
0.9
0.60
0.10
0.20
0.30
0.40
0.50
1.50
0.25
0.50
0.75
1.00
1.25
n= 2000 (min
-1
) n= 3000 (min
-1
)
n= 5000 (min
-1
) n= 7000 (min
-1
)
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
11/26
3 Gear pump group AP05
AP/APR05 Displacement Max. pressure n.min.
Type cm
3
/rev Cu.In.P.R.
P1 P2 P3
P< 100 P > 100 n.max.
bar P.S.I. bar P.S.I. bar P.S.I. bar bar
AP05/0.25 0.25 .015 170 2400 180 2600 200 2900 800 3000 7000
AP05/0.5 0.5 .030 190 2700 210 3000 230 3300 650 3000 7000
AP05/0.75 0.75 .045 190 2700 210 3000 230 3300 650 1500 7000
AP05/0.9 0.9 .055 190 2700 210 3000 230 3300 650 1500 7000
AP05/1.2 1.2 .073 170 2400 180 2600 200 2900 550 1500 6000
AP05/1.6 1.6 .097 170 2400 180 2600 200 2900 550 1500 6000
AP05/2.3 2.3 .139 150 2150 160 2300 180 2600 550 1500 4500
APR05/0.25 0.25 .015 150 2200 160 2300 180 2600 800 3000 7000
APR05/0.5 0.5 .030 170 2400 190 2700 210 3000 650 3000 7000
APR05/0.75 0.75 .045 170 2400 190 2700 210 3000 650 1500 7000
APR0.5/0.9 0.9 .055 170 2400 190 2700 210 3000 650 1500 7000
APR05/1.2 1.2 .073 150 2200 160 2300 180 2600 550 1500 6000
**0
**9
5
Last number of pump code
Max torque allowed to the shaft
7 +1.5 Nm
T max = 13 Nm
T max= 5 Nm
D
S
R
Clockwise (D) Counter-clockwise (S)
rotation
Reversible rotation
AP
APR ED
Notes:
- For uses at the operating limits, see note in section 2.8
- For the types of pumps without ordering code, contact our Sales Dept.
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
12/26
-.43”.11
11
19
10+2 Nm
ø7 DIN6888
.295”
Depth1/4” BSPP
.256”
2.05”
2.6”
1.004”
3.15”
2.047”
.866”-.864”
DIA
.275” DIA
.158”
.49”
.315”
.315”
.197”
.827”
.307”-.3”
.2756”-.2752”
.079”-.078”
25+5 Nm
7.5
A
4
21
88
5
12.5
66
25.5
80
52
M7
ø22 f8
52
2 h9
7 h6
7.8
0
-0.2
6.5
B
Suction-Pressure
.551”
14
8.5+1 Nm
1/8” BSPP
14
Drain
.29”
7.5
CodeGroup
AP05
APR05
810
Reversible pump
External Drain
Type
Displacement
cm
3
/rev
Dimensions
A B
mm inch. mm inch.
AP05/0.25 0.25 64.5 2.54 29 1.41
AP05/0.5 0.5 67 2.64 30.5 1.2
AP05/0.75 0.75 69 2.72 31.5 1.24
AP05/0.9 0.9 70.5 2.77 32 1.26
AP05/1.2 1.2 73 2.87 33.5 1.32
Clockwise rotation: D Counter-clockwise rotation: S Reversible pump - External Drain
Type Order Code Type Order Code Type Order Code
AP05/0.25 D 810 200100261204 AP05/0.25 S 810 200100261302 APR05/0.25 810 200100261101
AP05/0.5 D 810 200100361202 AP05/0.5 S 810 200100361302 APR05/0.5 810 200100361101
AP05/0.75 D 810 200100461202 AP05/0.75 S 810 200100461302 APR05/0.75 810 200100461101
AP05/0.9 D 810 200100561202 AP05/0.9 S 810 200100561302 APR05/0.9 810 200100561101
AP05/1.2 D 810 200100661202 AP05/1.2 S 810 200100661302 APR05/1.2 810 200100661101
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
13/26
25+5 Nm
19
1/4” BSPP
.197”-.196”
.216”
.374”
.295”
.49”
.158”
.866”-.864” DIA
2.047”
3.15”
1.004”
2.6”
2.05”
.256”
11 -.43”Depth
7.5
B
9.5
5.5
5 f7
6.5
52
ø22 f8
52
80
25.5
66
12.5
4
A
Suction-Pressure
CodeGroup 819
.551”
14
8.5+1 Nm
1/8” BSPP
14
Drain
.29”
7.5
AP05
APR05
Reversible pump
External Drain
Type
Displacement
cm
3
/rev
Dimensions
A B
mm inch. mm inch.
AP05/0.25 0.25 64.5 2.54 29 1.41
AP05/0.5 0.5 67 2.64 30.5 1.2
AP05/0.75 0.75 69 2.72 31.5 1.24
AP05/0.9 0.9 70.5 2.77 32.3 1.26
AP05/1.2 1.2 73 2.87 33.5 1.32
AP05/1.6 1.6 77 3.03 35.5 1.40
Clockwise rotation: D Counter-clockwise rotation: S Reversible pump - External Drain
Type Order Code Type Order Code Type Order Code
AP05/0.25 D 819 200100264208 AP05/0.25 S 819 200100264304 APR05/0.25 819
AP05/0.5 D 819 200100364202 AP05/0.5 S 819 200100364302 APR05/0.5 819 200100364101
AP05/0.75 D 819 200100464202 AP05/0.75 S 819 200100464302 APR05/0.75 819
AP05/0.9 D 819 200100564204 AP05/0.9 S 819 200100564304 APR05/0.9 819 200100564101
AP05/1.2 D 819 200100664202 AP05/1.2 S 819 200100664302 APR05/1.2 819 200100664101
AP05/1.6 D 819 200100864202 AP05/1.6 S 819 200100864301 APR05/1.6 819
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
14/26
20+5 Nm
19
10+2 Nm
11
.275” DIA
ø7 DIN6888
.256”
2.05”
2.6”
1.004”
3.15”
2.047”
.866”-.864”
DIA
.158”
.49”
.315”
.315”.197”
.827”
.079”-.078”
.945”
.307”-.3”
.2756”-.2752”
M7
A 21
8
8
5
12.5
66
25.5
80
52
ø22 f8
52
6.5
24
1/4” BSPP
2 h9
7 h6
7.8
0
-0.2
4
Suction-Pressure
CodeGroup AP05 310
Type
Displacement
cm
3
/rev
Dimensions
A
mm inch.
AP05/0.25 0.25 64.5 2.54
AP05/0.5 0.5 67 2.64
AP05/0.75 0.75 69 2.72
AP05/0.9 0.9 70.5 2.77
AP05/1.2 1.2 73 2.87
Clockwise rotation: D Counter-clockwise rotation: S
Type Order Code Type Order Code
AP05/0.25 D 310 200100261201 AP05/0.25 S 310 200100261301
AP05/0.5 D 310 200100361201 AP05/0.5 S 310 200100361301
AP05/0.75 D 310 200100461201 AP05/0.75 S 310 200100461301
AP05/0.9 D 310 200100561201 AP05/0.9 S 310 200100561301
AP05/1.2 D 310 200100661201 AP05/1.2 S 310 200100661301
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
15/26
.197”-.196”
.216”
.374”
.49”
.158”
.866”-.864” DIA
2.047”
3.15”
1.004”
2.6”
2.05”
.256”
.945”
.295”
19
20+5 Nm
9.5
5.5
5 f7
6.5
52
ø22 f8
52
80
25.5
66
12.5
4
A
24
1/4” BSPP
7.5
Suction-Pressure
CodeGroup AP05 319
Type
Displacement
cm
3
/rev
Dimensions
A
mm inch.
AP05/0.25 0.25 64.5 2.54
AP05/0.5 0.5 67 2.64
AP05/0.75 0.75 69 2.72
AP05/0.9 0.9 70.5 2.77
AP05/1.2 1.2 73 2.87
Clockwise rotation: D Counter-clockwise rotation: S
Type Order Code Type Order Code
AP05/0.25 D 319 200100214202 AP05/0.25 S 319 200100214301
AP05/0.5 D 319 200100314201 AP05/0.5 S 319 200100314301
AP05/0.75 D 319 200100414201 AP05/0.75 S 319 200100414301
AP05/0.9 D 319 200100514201 AP05/0.9 S 319 200100514301
AP05/1.2 D 319 200100614201 AP05/1.2 S 319 200100614301
AP05/1.6 D 319 200100814201 AP05/1.6 S 319 200100814301
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
16/26
OR 2025
20+5 Nm
19
.275” DIA
ø7 DIN6888
10+2 Nm
11
0.63”
Pressure
.197”
.256”
2.05”
2.6”
1.004”
3.15”
2.047”
.866”-.864” DIA
.158”
.49”
.315”
.315”
.197”
.827”
.307”-.3”
.2756”-.2752”
.079”-.078”
Suction
.945”
.29”
4
8
M7
16
5
A 21
8
8
5
12.5
66
25.5
80
52
ø22 f8
52
2 h9
7 h6
7.8
0
-0.2
6.5
24
1/4” BSPP
7.5
The drawing shows a pump with clockwise rotation.
CodeGroup AP05 410
Type
Displacement
cm
3
/rev
Dimensions
A
mm inch.
AP05/0.25 0.25 64.5 2.54
AP05/0.5 0.5 67 2.64
AP05/0.75 0.75 69 2.72
AP05/0.9 0.9 70.5 2.77
AP05/1.2 1.2 73 2.87
Clockwise rotation: D Counter-clockwise rotation: S
Type Order Code Type Order Code
AP05/0.25 D 410 200100261204 AP05/0.25 S 410 200100261304
AP05/0.5 D 410 200100361202 AP05/0.5 S 410 200100361304
AP05/0.75 D 410 200100461202 AP05/0.75 S 410 200100461302
AP05/0.9 D 410 200100561204 AP05/0.9 S 410 200100561302
AP05/1.2 D 410 200100661202 AP05/1.2 S 410 200100661302
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
17/26
Suction
19
20+5 Nm
Pressure
OR 2025
0.63”
.295”
.945”
2.047”
.866”-.864” DIA
.158”
.49”
.374”
.216”
.197”-.196”
.197”
.256”
2.05”
2.6”
1.004”
3.15”
.29”
16
7.5
1/4” BSPP
24
A
4
12.5
ø22 f8
52
5 f7
5.5
9.5
5
66
25.5
80
52
6.5
7.5
CodeGroup AP05 419
The drawing shows a pump with clockwise rotation.
Type
Displacement
cm
3
/rev
Dimensions
A
mm inch.
AP05/0.25 0.25 64.5 2.54
AP05/0.5 0.5 67 2.64
AP05/0.75 0.75 69 2.72
AP05/0.9 0.9 70.5 2.77
AP05/1.2 1.2 73 2.87
AP05/1.6 1.6 77 3.03
Clockwise rotation: D Counter-clockwise rotation: S
Type Order Code Type Order Code
AP05/0.25 D 419 AP05/0.25 S 419
AP05/0.5 D 419 200100364203 AP05/0.5 S 419 200100364304
AP05/0.75 D 419 AP05/0.75 S 419 200100464303
AP05/0.9 D 419 AP05/0.9 S 419
AP05/1.2 D 419 AP05/1.2 S 419
AP05/1.6 D 419 AP05/1.6 S 419 200100864302
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
18/26
.295”
X
To utilize M5x0.8 DIN912
X
7+1.5 Nm
1.26”
.295”
.827”
.197”
.315”
.315”
.158”
.866”-.864” DIA
2.047”
2.05”
.216”
1.182”
.079”-.078”
.2756”-.2752”
.307”-.3”
1/4” BSPP Depth 11 - .43”
25+5 Nm
19
ø7 DIN6888
.275” DIA
10+2 Nm
11
4
.256”
7.5
5.5
7.5
32
52
ø22 f8
M7
5 8 8
21
4B
C
A
52
30
7.8
0
-0.2
7 h6
2 h9
6.5
R
Suction-Pressure
CodeGroup 830
AP05
APR05
Reversible pump
External Drain
.551”
14
8.5+1 Nm
1/8” BSPP
14
Drain
.29”
7.5
Type
Displacement
cm
3
/rev
Dimensions
A B C
mm inch. mm inch. mm inch.
AP05/0.25 0.25 64.5 2.54 29 1.41 53.5 2.11
AP05/0.5 0.5 67 2.64 30.5 1.2 56 2.20
AP05/0.75 0.75 69 2.72 31.5 1.24 58 2.28
AP05/0.9 0.9 70.5 2.77 32 1.26 59.5 2.34
AP05/1.2 1.2 73 2.87 33.5 1.32 62 2.44
Clockwise rotation: D Counter-clockwise rotation: S Reversible pump - External Drain
Type Order Code Type Order Code Type Order Code
AP05/0.25 D 830 200100230201 AP05/0.25 S 830 200100230301 APR05/0.25 830
AP05/0.5 D 830 AP05/0.5 S 830 200100330301 APR05/0.5 830 200100330101
AP05/0.75 D 830 AP05/0.75 S 830 200100430301 APR05/0.75 830
AP05/0.9 D 830 AP05/0.9 S 830 200100530301 APR05/0.9 830 200100530101
AP05/1.2 D 830 AP05/1.2 S 830 200100631301 APR05/1.2 830
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
19/26
.295”
2.047”
.866”-.864” DIA
.158”
.295”
.374”
.216”
.197”-.196”
2.05”
1.182”
1.26”
19
25+5 Nm
1/4” BSPP
.216”
X
4
7+1.5 Nm
X
.256”
7.5
7.5
ø22 f8
52
5 f7
5.5
B
4
9.5
C
30
52
32
A
5.5
6.5
R
Depth 11 - .43”
To utilize M5x0.8 DIN912
Suction-Pressure
CodeGroup AP05 839
Type
Displacement
cm
3
/rev
Dimensions
A B C
mm inch. mm inch. mm inch.
AP05/0.25 0.25 64.5 2.54 29 1.41 53.5 2.11
AP05/0.5 0.5 67 2.64 30.5 1.2 56 2.20
AP05/0.75 0.75 69 2.72 31.5 1.24 58 2.28
AP05/0.9 0.9 70.5 2.77 32 1.26 59.5 2.34
AP05/1.2 1.2 73 2.87 33.5 1.32 62 2.44
AP05/1.6 1.6 77 3.03 35.5 1.40 66 2.60
Clockwise rotation: D Counter-clockwise rotation: S
Type Order Code Type Order Code
AP05/0.25 D 839 AP05/0.25 S 839
AP05/0.5 D 839 200100334201 AP05/0.5 S 839
AP05/0.75 D 839 200100434201 AP05/0.75 S 839 200100434304
AP05/0.9 D 839 200100534201 AP05/0.9 S 839 200100534302
AP05/1.2 D 839 200100634204 AP05/1.2 S 839 200100634301
AP05/1.6 D 839 200100834201 AP05/1.6 S 839 200100834301
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
20/26
.256”
X
.216”
X
7+1.5 Nm
4
20+5 Nm
19
ø7 DIN6888
DIA
.275”
10+2 Nm
11
2.05”
1.182”
.866”-.864”
DIA
.315”
.315”
.197”
.827”
.158”
1.26”
2.047”
.079”-.078”
.2756”-.2752”
.307”-.3”
.945”
.295”
5.5
21
885
M7
ø22 f8
52
A 4
B
32
30
52
7.8
0
-0.2
7 h6
2 h9
24
1/4” BSPP
7.5
6.5
R
To utilize M5x0.8 DIN912
Suction-Pressure
CodeGroup AP05 330
Type
Displacement
cm
3
/rev
Dimensions
A B
mm inch. mm inch.
AP05/0.25 0.25 64.5 2.54 53.5 2.11
AP05/0.5 0.5 67 2.64 56 2.20
AP05/0.75 0.75 69 2.72 58 2.28
AP05/0.9 0.9 70.5 2.77 59.5 2.34
AP05/1.2 1.2 73 2.87 62 2.44
Clockwise rotation: D Counter-clockwise rotation: S
Type Order Code Type Order Code
AP05/0.25 D 330 AP05/0.25 S 330
AP05/0.5 D 330 AP05/0.5 S 330
AP05/0.75 D 330 AP05/0.75 S 330
AP05/0.9 D 330 200100531201 AP05/0.9 S 330
AP05/1.2 D 330 AP05/1.2 S 330
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
21/26
.256”
1.26”
1.182”
2.05”
.197”-.196”
.216”
.374”
.866”-.864” DIA
2.047”
.157”
.945”
.216”
19
20+5 Nm
X
4
7+1.5 Nm
X
.295”
52
30
32
B
9.5
5.5
5 f7
52
ø22 f8
A 4
1/4” BSPP
24
5.5
7.5
6.5
R
To utilize M5x0.8 DIN912
Suction-Pressure
CodeGroup AP05 339
Type
Displacement
cm
3
/rev
Dimensions
A B
mm inch. mm inch.
AP05/0.25 0.25 64.5 2.54 53.5 2.11
AP05/0.5 0.5 67 2.64 56 2.20
AP05/0.75 0.75 69 2.72 58 2.28
AP05/0.9 0.9 70.5 2.77 59.5 2.34
AP05/1.2 1.2 73 2.87 62 2.44
AP05/1.6 1.6 77 3.03 66 2.60
Clockwise rotation: D Counter-clockwise rotation: S
Type Order Code Type Order Code
AP05/0.25 D 339 200100234201 AP05/0.25 S 339 200100234303
AP05/0.5 D 339 200100334203 AP05/0.5 S 339 200100334303
AP05/0.75 D 339 200100434202 AP05/0.75 S 339 200100434302
AP05/0.9 D 339 200100534203 AP05/0.9 S 339 200100534303
AP05/1.2 D 339 200100634203 AP05/1.2 S 339 200100634303
AP05/1.6 D 339 200100834202 AP05/1.6 S 339 200100834302
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
22/26
.295”
.197”
.295”
2.05
1.182”
.866”-.864”
DIA
.315”
.315”
.197”
.827”
.307”-.3”
.2756”-.2752”
.079”-.078”
.945”
.158”
.216”
1.26”
2.047”
.63”
20+5 Nm
19
Suction
.275”
DIA
ø7 DIN6888
11
10+2 Nm
7+1.5 Nm
4
X
X
Pressure
OR 2025
.256”
30
7,5
5
7,5
21
8
8
5
M7
ø22 f8
52
2 h9
7 h6
7.8
0
-0.2
24
1/4” BSPP
A
4
B
32
52
16
5,5
6.5
R
To utilize M5x0.8 DIN912
CodeGroup AP05 430
The drawing shows a pump with clockwise rotation.
Type
Displacement
cm
3
/rev
Dimensions
A B
mm inch. mm inch.
AP05/0.25 D 0.25 64.5 2.54 53.5 2.11
AP05/0.5 D 0.5 67 2.64 56 2.20
AP05/0.75 D 0.75 69 2.72 58 2.28
AP05/0.9 D 0.9 70.5 2.77 59.5 2.34
AP05/1.2 D 1.2 73 2.87 62 2.44
Clockwise rotation: D Counter-clockwise rotation: S
Type Order Code Type Order Code
AP05/0.25 D 430 200100231201 AP05/0.25 S 430
AP05/0.5 D 430 200100331201 AP05/0.5 S 430
AP05/0.75 D 430 AP05/0.75 S 430
AP05/0.9 D 430 AP05/0.9 S 430
AP05/1.2 D 430 AP05/1.2 S 430
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
23/26
.256”
20+5 Nm
19
Suction
X
.216”
.63”
.197”-.196”
.216”
.374”
DIA
.866”-.864”
2.047”
.945”
.157”
.295”
.197”
.295”
2.05
1.182”
1.26”
X
4
7+1.5 Nm
OR 2025
Pressure
5,5
16
B
9,5
5.5
5 f7
52
ø22 f8
1/4” BSPP
24
A 4
30
7,5
5
7,5
32
52
6.5
R
To utilize M5x0.8 DIN912
CodeGroup AP05 439
The drawing shows a pump with clockwise rotation.
Type
Displacement
cm
3
/rev
Dimensions
A B
mm inch. mm inch.
AP05/0.25 D 0.25 64.5 2.54 53.5 2.11
AP05/0.5 D 0.5 67 2.64 56 2.20
AP05/0.75 D 0.75 69 2.72 58 2.28
AP05/0.9 D 0.9 70.5 2.77 59.5 2.34
AP05/1.2 D 1.2 73 2.87 62 2.44
AP05/1.6 D 1.6 77 3.03 66 2.60
Clockwise rotation: D Counter-clockwise rotation: S
Type Order Code Type Order Code
AP05/0.25 D 439 200100234202 AP05/0.25 S 439 200100234302
AP05/0.5 D 439 200100334202 AP05/0.5 S 439 200100334302
AP05/0.75 D 439 200100434204 AP05/0.75 S 439 200100434303
AP05/0.9 D 439 200100534202 AP05/0.9 S 439
AP05/1.2 D 439 200100634202 AP05/1.2 S 439 200100634305
AP05/1.6 D 439 AP05/1.6 S 439
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
24/26
3.1 Pumps seal kit NBR standard type
AP05
Pump code Seal kit
AP05/810
200974000180
AP05/819
AP05/310
AP05/319
AP05/830
AP05/839
200974000180
AP05/330
AP05/339
AP05/410
200974000280
AP05/419
AP05/430
AP05/439
4 Composition of product code
4.1 Single pumps
Type Rotation Code
AP05/** * ****
APR05/** * ****
Examples Order Code
AP05/0.75 D 819 200100464202
APR05/0.5 810 200100361101
4.2 Product identification plate
S 4A/****
AP05/0.5 S 819
200100364202
1
2
3
4
5
MADE IN ITALY
1 : Rotation (D= Clockwise rotation - S= Counterclockwise
rotation)
2 : Manufacturing year and month
3 : Progressive identification no. (optional)
4 : Bucher Hydraulics S.p.A. product code
5 : Description
4.3 Single pump weight
AP-APR05
Pump Weight Kg
AP-APR05/0.25 0.45
AP-APR05/0.5 0.45
AP-APR05/0.75 0.45
AP-APR05/0.9 0.48
AP-APR05/1.2 0.50
AP-APR05/1.6 0.50
N.B.: The weight refers to pumps with version code 810 (AP05)
Limited weight variations are possible for pumps having a different code.
Manufacturing
month
Manufacturing year
2014 2015 2016 2017 2018 2019
January 4A 5A 6A 7A 8M 9M
February 4B 5B 6B 7B 8N 9N
March 4C 5C 6C 7C 8P 9P
April 4D 5D 6D 7D 8Q 9Q
May 4E 5E 6E 7E 8R 9R
June 4F 5F 6F 7F 8S 9S
July 4G 5G 6G 7G 8T 9T
August 4H 5H 6H 7H 8U 9U
September 4I 5I 6I 7I 8V 9V
October 4J 5J 6J 7J 8Z 9Z
November 4K 5K 6K 7K 8X 9X
December 4L 5L 6L 7L 8Y 9Y
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
25/26
PHASE OUT
200-P-991218-EN-05/09.2015
AP05
26/26
E 2020 by Bucher Hydraulics S.p.A, I-42124 Reggio Emilia
www.bucherhydraulics.co
m
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The
information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual
improvement, we reserve the right to amend the product specifications contained in this catalogue.
Classification: 410.110.000
PHASE OUT