Axial piston variable double pump
A21VG series 20
Features
▶ Variable double pump with two axial piston rotary
groups of swashplate design for hydrostatic drives in
a closed circuit
▶ The ow is proportional to the drive speed and
displacement
▶ The ow can be innitely varied by adjusting the
swashplate angle.
▶ Flow direction changes smoothly when the swashplate
is moved through the neutral position.
▶ Only one shared port for case drain uid for both cir-
cuits
▶ Compact design for tight installation conditions
RE-A93224/2025-02-12, Bosch Rexroth Corporation
▶ Size 35, 45
▶ Nominal pressure 420 bar
▶ Maximum pressure 450 bar
▶ Closed circuit
RE-A93224
Edition: 2025-02-12
Replaces: 2024-08-05
Contents
Ordering code 2
Hydraulic uid 4
Shaft seal 5
Operating pressure range 6
Technical data 7
EP−Proportional control electric 9
HT−Hydraulic control, direct operated 11
HW−Proportional control hydraulic,
mechanical servo 12
ET−Electric control, direct operated 14
eEP – Proportional Control Operation
with electronic feedback 15
Dimensions 16
Through drive dimensions 20
Overview of attachment options 20
High-pressure relief valves 21
Mechanical stroke limiter 22
Pilot shut-off valve (Neutral valve) 23
DA−Control valve, xed setting 25
Swivel angle sensor 27
Connector for solenoids 28
Installation dimensions for coupling assembly 28
Installation instructions 29
Project planning notes 31
Safety instructions 32
Bosch Rexroth Corporation, RE-A93224/2025-02-12
2 A21VG series 20 | Axial piston variable double pump
Ordering code
Axial piston unit
01 Variable swashplate design A21V
Operating mode
02 Pump in closed circuit G
Size (NG)
03 Displacement 35 45
Control device 35 45
04 Hydraulic control direct operated – optimized for hydraulic control ● ● HT1
Proportional electric control, mechanical feedback – 12 V DC ● ● EP1
Proportional electric control, mechanical feedback – 24 V DC ● ● EP2
Proportional electric control, direct operated, two pressure reducing valves – 12 V DC
eEP proportional control operation with electronic feedback, see Page 15
● ● ET1
Proportional electric control, direct operated, two pressure reducing valves – 24 V DC
eEP proportional control operation with electronic feedback, see Page 15
● ● ET2
Proportional hydraulic control with mechanical servo, hexagon shaft with lever, free position ● ● HW1
Proportional hydraulic control with mechanical servo, hexagon shaft with lever, free position
including neutral switch
● ● HW8
Connector for solenoids 35 45
05 Without connector (without solenoid, only for hydraulic control) ● ● 0
DEUTSCH molded connector, 2-pin – without suppressor diode ● ● P
Swivel angle sensor 35 45
06 Without swivel angle sensor ● ● 0
Electric swivel angle sensor mounted – mandatory for eEP operation (see page Page 15) ● ● D
Mechanical stroke limiter
07 Without mechanical stroke limiter 0
With mechanical stroke limiter M
Valve options 35 45
08 Without pilot shut-off valve or DA valve ● ● 0
DA control valve xed setting (not possible with pilot shut off) ● ● 1
Pilot shut-off valve – 12 V DC
● ● 3
Pilot shut-off valve – 24 V DC ● ● 4
Series
09 Series 2, index 0 20
Conguration
10 ANSI, port threads with O-ring seal according to ISO 11926
A
Direction of rotation
11 Viewed on drive shaft clockwise R
counter-clockwise L
Ordering code
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17
A21V G / 20 A N B2 –
● = Available options ○ = On request
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Ordering code
3
Seals
12 NBR (nitrile-caoutchouc), shaft seal in FKM (uoro-caoutchouc) N
Mounting ange
13 SAE J744 101-2 B2
Drive shaft 35 45
14 Splined shaft ANSI B92.1a-1976 (1 in 15T 16/32DP) ● ● S5
Splined shaft ANSI B92.1a-1976 (1¼ in 14T 12/24DP) ● ● S7
Service line ports 35 45
15 Threaded ports A and B, left (viewed on drive shaft) ● ● 3
Threaded ports A and B, right (viewed on drive shaft) – consult factory ○ ○ 4
Through drive 35 45
16 Without through drive ● ● 0000
Flange SAE J744
Diameter Mounting Code
Hub for splined shaft
Diameter Code
82-2 (A)
A2 5/8 in 9T 16/32DP S2 ● ● A2S2
A2 3/4 in 11T 16/32DP S3 ● ● A2S3
A2 7/8 in 13T 16/32DP S4 ● ● A2S4
101-2 (B)
B2 7/8 in 13T 16/32DP S4 ● ● B2S4
B2 1 in 15T 16/32DP S5 ● ● B2S5
Standard / special version
17 Standard version 0
Standard version with installation variant, e.g. “T” plugged vs open Y
Special version, e.g. 35cc displacement 2
nd
pump, different controller 2
nd
pump, etc. S
● = Available options ○ = On request
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17
A21V G / 20 A N B2 –
Bosch Rexroth Corporation, RE-A93224/2025-02-12
4 A21VG series 20 | Axial piston variable double pump
Hydraulic uid
Hydraulic uid
The axial piston unit is designed for operation with HLP
mineral oil according to DIN 51524. Application instruc-
tions and requirements for hydraulic uid selection,
behavior during operation as well as disposal and environ-
mental protection should be taken from the following data
sheets before the start of project planning:
▶ 90220: Hydraulic uids based on mineral oils and
related hydrocarbons
▶ 90221: Environmentally acceptable hydraulic uids
▶ 90222: Fire-resistant, water-free hydraulic uids
(HFDR/HFDU)
▶ 90225: Limited technical data for operation with water
-
free and water-containing re-resistant hydraulic uids
▶ (HFDR, HFDU, HFAE, HFAS, HFB, HFC)
Notes on selection of hydraulic uid
The hydraulic uid should be selected so that the operat-
ing viscosity in the operating temperature range is within
the optimum range (νopt see selection diagram).
Viscosity and temperature of hydraulic uids
Viscosity [SUS (mm
2
/s)] Shaft seal Temperature
3)
Comment
Cold start
ν
max
≤ 7400 (1600)
NBR
2)
θ
St
≥−40°F (−40°C) t ≤ 3 min, without load (p ≤ 725 psi (50 bar), n ≤ 1000 rpm
Permissible temperature difference between axial piston
unit and hydraulic uid in the system maximum 45°F (25K).
FKM
θ
St
≥−13 °F (−25°C)
Warm-up phase
ν = 7400…1850
(1600…400)
t ≤ 15 min, p ≤ 0.7×p
nom
and n ≤ 0.5×n
nom
Continuous
operation
ν = 1850…60
1)
(400…10)
NBR
2)
θ ≤ +185°F (+85°C)
measured at port T
FKM
θ ≤ +230°F (+110°C)
ν
opt
= 170…82
(36…16)
Range of optimum operating viscosity and efciency
Short-term
operation
ν
min
= 60…49
(10…7)
NBR
2)
θ ≤ +185°F (+85°C) t ≤ 3 min, p ≤ 0.3×p
nom
, measured at port T
FKM
θ ≤ +230°F (+110°C)
▼ Selection diagram
−40
(−40)
−13
(−25)
14
(−10)
50
(10)
86
(30)
104
(40)
122
(50)
195
(90)
240
(115)
158
(70)
32
(0)
49 (7)
60 (10)
190 (40)
280 (60)
100 (20)
460 (100)
930 (200)
1850 (400)
2800 (600)
4600 (1000)
7400 (1600)
VG 22
VG 32
VG 46
VG 68
VG 100
82 (16)
170 (36)
Maximum permissible viscosity for cold start
Viscosity ν
Warm-up phase
Continuous operation
ν
opt
Minimum permissible viscosity at short-term operation
Temperature θ
[°F (°C)]
SUS (mm
2
/s)
1) Corresponds e.g. for VG 46 to a temperature range of +39°F
(+4°C) to +185°F (+85°C) (see selection diagram)
2) Special version, please contact us
3) If the temperature at extreme operating parameters cannot be
adhered to, please contact us.
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Shaft seal
5
Filtration of the hydraulic uid
Finer ltration improves the cleanliness level of the hydraulic
uid, which increases the service life of the axial piston unit.
A cleanliness level of at least 20/18/15 is to be maintained
according to ISO 4406.
We recommend, depending on the system and application,
for the A21VG: lter cartridges β
20
≥ 100.
At very high hydraulic uid temperatures (90°C to maxi-
mum 110°C, measured at port T), a cleanliness level of at
least 19/17/14 according to ISO 4406 is necessary.
Shaft seal
Permissible pressure loading
The service life of the shaft seal is inuenced by the
speed of the axial piston unit and the leakage pressure in
the housing (case pressure). Momentary pressure spikes
(t<0.1s) of up to 10bar are permitted. The service life
of the shaft seal decreases with increasing frequency of
pressure spikes and increasing mean differential pressure.
The case pressure must be equal to or higher than the
ambient pressure.
1000
0
1
2
3
4
5
2000 3000 4000
NG45
Differential pressure Δp [bar]
Rotational speed n [rpm]
The FKM shaft seal may be used for leakage temperatures
from
−25 °C to +115 °C. For application cases below
−25 °C, an NBR shaft seal is required (permissible tem-
perature range:
−40 °C to +90 °C).
Bosch Rexroth Corporation, RE-A93224/2025-02-12
6 A21VG series 20 | Axial piston variable double pump
Operating pressure range
Operating pressure range
Pressure at service line port A or B Denition
Nominal pressure p
nom
420 bar The nominal pressure corresponds to the maximum design pressure.
Maximum pressure p
max
450 bar The maximum pressure corresponds to the maximum operating pressure within
the single operating period. The sum of the single operating periods must not
exceed the total operating period.
Single operating period 1s
Total operating period 50 h
Minimum pressure
(high-pressure side)
25 bar Minimum pressure at the high-pressure side (A or B) which is required in order
to prevent damage to the axial piston unit.
Minimum pressure (low-pressure
side)
10 bar above
case pressure
Minimum pressure at the low-pressure side (A or B) which is required in order to
prevent damage to the axial piston unit. Boost pressure setting must be higher
depending on system.
Rate of pressure change R
Amax
9000bar/s Maximum permissible rate of pressure build-up and reduction during a pressure
change over the entire pressure range.
Charge pressure
Maximum charge pressure G port 30 bar
Control pressure
Minimum control pressure p
St
min
To ensure the function of the control, a minimum control pressure p
St
min
at
n=2000rpm is required depending on the rotational speed and operating pressure.
Controls EP and HW 18bar above
case pressure
Controls ET and HT
25bar above
case pressure
▼ Rate of pressure change R
Amax
p
nom
∆t
∆p
Time t
Pressure p
▼ Pressure denition
Pressure p
t
1
t
2
t
n
Single operating period
Minimum pressure (high-pressure side)
Maximum pressure p
max
Nominal pressure p
nom
Time t
Total operating period = t
1
+ t
2
+ ... + t
n
Note
Operating pressure range valid when using hydraulic
uids based on mineral oils. Values for other hydraulic
uids, please contact us.
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Technical data
7
Technical data
Size NG 35 45
Displacement geometric,
per revolution
variable pump (for each rotary group)
V
gmax
cm
3
2 x 35 2x45
Rotational speed
1)
maximum at V
gmax
n
nom
rpm 3300 3300
limited maximum
2)
n
max1
rpm 3550 3550
intermittent maximum
3)
n
max2
rpm 3800 3800
minimum
n
min
rpm 500 500
Flow
at V
gmax
andn
nom
q
v
l/min 2 x 115 2 x 148
Power
4)
at V
gmax
, n
nom
and Δp=380bar P
kW 146 187
Torque
4)
at V
g max
and Δp=300bar T
Nm 334 429
Δp = 100 bar T
Nm 111 143
Rotary stiffness drive shaft 11/4in S7 Pump 1
c
1
Nm/rad 59.401 59.401
Pump 2
c
2
Nm/rad 13.430 13.430
Moment of inertia
(see graphic below)
rotary group 1
J
TW1
kgm
2
0.003560 0.003524
rotary group 2
J
TW2
kgm
2
0.003511 0.003475
Maximum angular acceleration for each rotary group
5)
α
rad/s² 4000 4000
Case volume
V
L 1.7 1.7
Weight with HT control (approx.)
m
kg 59 59
Determination the operating characteristics
Flow
q
v
=
V
g
× n × η
v
[l/min]
1000
Torque
T
=
V
g
× Δp
[Nm]
20 × π × η
mh
Power
P
=
2 π × T × n
=
q
v
× Δp
[kW]
60000
600 × η
t
Key
V
g
= Displacement per revolution [cm
3
]
Δp
= Differential pressure [bar]
n
= Rotational speed [rpm]
η
v
= Volumetric efciency
η
mh
= Mechanical-hydraulic efciency
η
t
= Total efciency (η
t
= η
v
× η
mh
)
▼ Spring-mass system with moment of inertia
c1 c2
J
TW1
J
TW2
Notes
▶ Theoretical values, without efciency levels and
tolerances; values rounded
▶ Operation above the maximum values or below
the minimum values may result in a loss of function,
a reduced service life or in the destruction of the
axial piston unit. Bosch Rexroth recommends
checking the loading by means of testing or calcu-
lation / simulation and comparison with the permis-
sible values.
▶ Transport and storage
– θ
min
≥–50°C
– θ
opt
=+5°C to +20°C
1) The values are valid:
– for the optimum viscosity range of ν
opt
=36 to 16mm
2
/s
– with hydraulic uid based on mineral oil
2) Limited maximum speed:
At half corner power (e.g., at V
gmax
and p
nom
/2)
3) Intermittent maximum speed at:
– high idle
– overspeed: ∆p=70to150bar and V
gmax
– reversing peaks: ∆p<300 bar and t<0.1s.
4) Without boost pump
5) The data are valid for values between the minimum required and
maximum permissible rotational speed. Valid for external excita
-
tion (e. g. diesel engine 2 to 8 times rotary frequency; cardan
shaft twice the rotary frequency). The limit value applies for a
single pump only. The load capacity of the connection parts must
be considered.
Bosch Rexroth Corporation, RE-A93224/2025-02-12
8 A21VG series 20 | Axial piston variable double pump
Operating pressure range
Permissible radial and axial forces of the drive shaft
Size NG 35 45
Drive shaft in 1-1/4 1-1/4
Maximum radial force at distance a
(from shaft collar)
a
F
q
F
q max
N 3190 3190
a mm 24 24
Maximum axial force
±
F
ax
± F
ax max
N 1500 1500
Note
Special requirements apply in the case of belt drive
and cardan shaft. Please contact us.
Permissible input and through-drive torques
Size NG 35 45
Torque at V
gmax
and Δp=420bar
1)
T
Nm 468 602
Maximum input torque at drive shaft
2)
S5 1 in 342 342
S7 1-1/4in
T
E max
Nm 602 602
Maximum through-drive torque
T
D1 max
Nm 318 318
T
D2 max
Nm
318–T
2
T
D2perm
=318–T
2
▼ Torque distribution
T
1
T
D1
T
D2
T
E
T
2
T
3
A21VG
Pump 1 Pump 2
Attachment pump
Torque – A21VG 1st pump
T
1
2nd pump
T
2
Torque – attachment pump
T
3
Input torque
T
E
=
T
1
+ T
2
+ T
3
T
E
<
T
E max
Through-drive torque
T
D1
T
D2
1)
Efciency not considered
2) For drive shafts without radial force
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
EP−Proportional control electric
9
EP−Proportional control electric
The output ow of the pump is innitely variable between
0to100%, proportional to the electrical current supplied
to solenoid a or b.
The electrical energy is converted into a force acting on
the control spool. This valve spool then directs control oil
into and out of the stroking cylinder to adjust pump dis-
placement as required.
A feedback lever, connected to the stroking piston maintains
the pump ow for a given current within the control range.
I [mA]
EP1
EP2
I
[mA]
0.2 0.4 0.6 0.8 1.00.40.60.81.0
1200
1000
800
600
400
200
0
00.2
V
g
V
g max
V
g
V
g max
200
400
600
800
1000
1200
(Solenoid A)
(Solenoid B)
Technical data, solenoid EP1 EP2
Voltage 12V(±20%) 24V(±20%)
Control current
Beginning of control at V
g
=0 400 mA 200 mA
End of control at V
g max
1115 mA 560 mA
Current limit 1.54 A 0.77 A
Nominal resistance (at 20°C) 5.5Ω 22.7Ω
Dither frequency 100 Hz 100 Hz
Duty cycle 100 % 100 %
Type of protection, see connector version on page Page 28
Various BODAS controllers with application software and
ampliers are available for controlling the proportional
solenoids.
Further information can also be found on the internet at
www.boschrexroth.com/mobile-electronics.
▼ Schematic
A
A
B
B
R
T1
a
b
b
a
Bosch Rexroth Corporation, RE-A93224/2025-02-12
10 A21VG series 20 | Axial piston variable double pump
EP−Proportional control electric
Assignment of direction of rotation, control and ow direction
Direction of rotation clockwise counter-clockwise
Pump Pump 1 Pump 2 Pump 1 Pump 2
Actuation of solenoid b a b a b a b a
Control pressure X
1
X
2
X
1
X
2
X
1
X
2
X
1
X
2
Flow direction B to A A to B A to B B to A A to B B to A B to A A to B
X
2
,
R, X
1
X
1
,
X
2
X
1
Solenoid b Solenoid a
Solenoid a Solenoid b
X
2
X
2
X
1
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
HT−Hydraulic control, direct operated
11
HT−Hydraulic control, direct operated
With the direct hydraulic control, the ow of the pump is
inuenced by a hydraulic control pressure that is applied
directly to the stroking piston through X
1
or X
2
. Flow direc-
tion is determined by which control pressure port is pres-
surized (refer to table below).
Pump displacement is innitely variable and proportional
to the applied control pressure, but is also inuenced by
system pressure and pump drive speed.
Maximum permissible control pressure: 30 bar
Use of the HT control requires a review of the engine and
vehicle parameters to ensure that the pump is set up
correctly. We recommend that all HT applications be
reviewed by a Bosch Rexroth application engineer.
X
2
,
R, X
1
X
1
,
X
2
X
2
X
1
X
1
X
2
▼ Schematic
A
A
B
B
X1
X2
G
R
T1
X1
X2
Assignment of direction of rotation, control and ow direction
Direction of rotation clockwise counter-clockwise
Pump Pump 1 Pump 2 Pump 1 Pump 2
Control pressure X
1
X
2
X
1
X
2
X
1
X
2
X
1
X
2
Flow direction B to A A to B A to B B to A A to B B to A B to A A to B
Bosch Rexroth Corporation, RE-A93224/2025-02-12
12 A21VG series 20 | Axial piston variable double pump
HW−Proportional control hydraulic, mechanical servo
HW−Proportional control hydraulic, mechanical servo
The output ow of the pump is innitely variable between
0to 100%, proportional to the swivel angle of the control
lever.
A feedback lever, connected to the stroking piston maintains
the pump ow for a given position of the control lever.
If the pump is also equipped with a DA control valve
(see page Page 25), automotive operation is possible
for travel drives.
β [°]
0 0.2 0.4 0.6 0.8 1.00.20.40.60.81.0
40
35
30
25
20
15
10
5
0
5
10
15
20
25
30
35
40
V
g
β [°]
V
g max
V
g
V
g max
Swivel angle β at the control lever for pump displacement
change:
▶ Start of control at β = ±3°
▶ End of control at β (max. displacement V
g max
) at ±30°
▶ Rotation limiting β of the control lever (internal) ±38°
The maximum required torque at the lever is 170 Ncm.
To prevent damage to the HW control module, a mechani-
cal stop must be provided by the customer for the HW
control lever.
Note
Spring centering enables the pump, depending on pres-
sure and rotational speed, to move automatically to the
neutral position (V
g
=0) as soon as there is no longer
any torque on the control lever of the HW control mod-
ule (regardless of deection angle).
Variation: Neutral position switch
The switch contact in the neutral position switch is closed
when the control lever on the HW control module is in its
neutral position. The switch opens when the control lever
is moved out of neutral in either direction.
Thus, the neutral position switch provides a monitoring
function for drive units that require the pump to be in the
neutral position during certain operating conditions (e.g.
starting diesel engines).
Technical data
Load capacity 20 A (continuous), without switching
operations
Switching capacity 15 A / 32 V (resistive load)
4 A / 32 V (inductive load)
Connector version DEUTSCHDT04-2P-EP04
(Mating connector, see page Page 28)
▼ Schematic
A
A
B
B
X1 X2
G
R
T1
X1 X2
a
b
b
a
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
HW−Proportional control hydraulic, mechanical servo
13
Assignment of direction of rotation, control and ow direction
Direction of rotation clockwise counter-clockwise
Pump Pump 1 Pump 2 Pump 1 Pump 2
Lever direction a b a b a b a b
Control pressure X
1
X
2
X
1
X
2
X
1
X
2
X
1
X
2
Flow direction B to A A to B A to B B to A A to B B to A B to A A to B
X
1
X
2
,
R, X
1
X
1
,
X
2
X
2
X
2
X
1
Bosch Rexroth Corporation, RE-A93224/2025-02-12
14 A21VG series 20 | Axial piston variable double pump
ET−Electric control, direct operated
ET−Electric control, direct operated
The output ow of the pump is innitely variable in the
range 0 to 100%. Depending on the preselected current
I (mA) at solenoids a and b of the pressure reducing valves,
the stroking cylinder of the pump is proportionally supplied
with control pressure. The pump displacement that arises
at a certain control current is dependent on the rotational
speed and operating pressure of the pump. A different ow
direction is associated with each pressure reducing valve.
Maximum permissible control pressure: 30 bar
Technical data, solenoid ET1 ET2
On-board voltage in the vehicle 12 V 24 V
Permissible voltage U 9.6 ... 28.8 V
Current limit 1.5 A
Nominal resistance (at 20°C) 3.3Ω
Dither
Frequency 100 Hz
Minimum oscillation range
1)
250 mA
Duty cycle 100 %
Type of protection, see connector version on Page 28
1) Minimum required oscillation range of the control current ΔIp-p (peak to peak)
within the respective control range (start of control to end of control).
X
2
,
R, X
1
X
1
,
X
2
X
1
Solenoid a Solenoid b
Solenoid b Solenoid a
X
2
X
2
X
1
▼ Schematic
B B
R
b
a
a
b
T1
0 400 800 1000
1200
35
30
25
20
15
10
5
0
Pressure [bar]
Current I [mA]
Assignment of direction of rotation, control and ow direction
Direction of rotation clockwise counter-clockwise
Pump Pump 1 Pump 2 Pump 1 Pump 2
Actuation of solenoid a b a b a b a b
Control pressure X
1
X
2
X
1
X
2
X
1
X
2
X
1
X
2
Flow direction B to A A to B A to B B to A A to B B to A B to A A to B
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
eEP – Proportional Control Operation with electronic feedback
15
eEP – Proportional Control Operation with electronic feedback
The pump displacement electronic control characteristic
is similar to the EP controller, which can now be achieved
by using the ET controller in conjunction with swashplate
angle sensors and Rexroth’s RC controller and software.
Our traditional EP controller uses a feedback lever to
mechanically compensate the pump displacement and
achieve a high level of accuracy and response time in
order to provide constant ow for given current input
independent from the load pressure.
The design of the A21VG pump, including the placement
and design integration of the angle sensors, has been
setup such that the effect of tolerances are minimized and
best-in-class control performance can be achieved. A
pump with load dependent ET functionality – where load
pressure deects the swash plate position – can have now
added load compensation by a simple programming
parameter to emulate EP functionality. In the end, the
control algorithm achieves perfect linearity, with minimal
hysteresis, independently of the hydraulic unit load pressure.
Assignment of direction of rotation, control and ow direction
Direction of rotation clockwise counter-clockwise
Pump Pump 1 Pump 2 Pump 1 Pump 2
Actuation of solenoid a b a b a b a b
Control pressure X
1
X
2
X
1
X
2
X
1
X
2
X
1
X
2
Flow direction B to A A to B A to B B to A A to B B to A B to A A to B
Ch1, Pin 4
1)
0.7 V 4.3 V 0.7 V 4.3 V 0.7 V 4.3 V 0.7 V 4.3 V
Ch2, Pin 1
1)
4.3 V 0.7 V 4.3 V 0.7 V 4.3 V 0.7 V 4.3 V 0.7 V
1) Angle sensor voltage @ V
g max
With the potential to use the eEP option, customers can
design machines to suit operator’s personal preference on
how they would like to control the machine without the
need to change hardware. Some customers may prefer to
have “soft controllability” of the pump where they would
want to feel the inuence of pump operating pressure
relative to their input command. Other customers may
prefer the pump to have “hard controllability” where the
pump swivels to commanded displacement regardless of
the pump operating pressure. Both “hard” and “soft”
functionality can be achieved via a simple programming
change on-the-y. This opens up possibilities for different
drive modes available to the machine operator and allows
the OEM to program behavior preferences based on other
machine operating parameters.
Bosch Rexroth Corporation, RE-A93224/2025-02-12
16 A21VG series 20 | Axial piston variable double pump
Dimensions
Dimensions
ET.D – Electric control, direct operated with angle sensor
Threaded ports A and B, on left side (viewed on drive shaft)
103.6
107.6
278.6
391.7
9.7
68.5
91
130.5
136.6
245.6
92.3
289.9
n 10
2
190.5
26
146
14.3
28.2
141.6
129.1
106.3
146
88.3
50.9
50.9
92
2.5
169.3
212.9
25
25
92.6
302.6
79.6
30.6
351.6
48.3
48.3
112.2
112
Ø101.6–0.054
Center of gravity
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Dimensions
17
▼ Splined shaft SAEJ744
S5 ‒ 1in15T16/32DP
1)
S7 ‒ 11/4in14T12/24DP
1)
Ø20.8
0
–0.2
8.3
46.3
Ø80
Ø35
Ø25.8
0
–0.2
Ø80
Ø35
8.3
56.3
Ports Standard
3)
Size [in]
4)
p
max abs
[bar]
5)
State
6)
A, B Working port ISO 11926 11/16-12UN-2B; 20deep 450 O
T Drain port ISO 11926 11/16-12UN-2B; 20deep 3 O
R Air bleed on pump 1 ISO 11926 9/16-18 UNF-2B; 13 deep 3 X
X
1
, X
2
Control pressure
(upstream of orice, only HP, HW, EP, ET)
ISO 11926 9/16-18 UNF-2B; 13 deep 30 X
X
1
, X
2
Control pressure (HT) ISO 11926 9/16-18 UNF-2B; 13 deep 30 O
Y Pilot pressure, outlet
(only for DA control valve)
ISO 11926 9/16-18 UNF-2B; 13 deep 30 O
G Boost pressure, inlet ISO 11926 3/4-16 UNF-2B; 15 deep 30 O
Y
BR
Brake release pressure ISO 11926 9/16-18 UNF-2B; 13 deep 30 X
P
S
Pilot pressure supply (ltered internally) ISO 11926 9/16-18 UNF-2B; 13 deep 30 X
G
1
Boost pressure, inlet (only for DA control valve) ISO 11926 9/16-18 UNF-2B; 13 deep 30 X
1) Involute spline according to ANSI B92.1a, 30° pressure angle, at
root, side t, tolerance class 5
2) Thread according to ASME B1.1
3) The spot face can be deeper than specied in the appropriate
standard.
4) For notes on tightening torques, see instruction manual
5) Momentary pressure spikes may occur depending on the
application. Keep this in mind when selecting measuring
devices and ttings.
6) O = Must be connected (plugged on delivery)
X = Plugged (normal operation)
Bosch Rexroth Corporation, RE-A93224/2025-02-12
18 A21VG series 20 | Axial piston variable double pump
Dimensions
▼ EP – Proportional control, electric
35.1
347.1
380.4
110.5
147.2
77
109.2
109.2
122
X
2
,
R, X
1
X
1
,
X
2
X
1
X
2
X
2
X
1
▼ HT – Hydraulic control, direct operated
87
122
141.6
77
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Dimensions
19
▼ HW – Proportional control hydraulic, mechanical servo
68
33
27
50
63
∅8
Bosch Rexroth Corporation, RE-A93224/2025-02-12
20 A21VG series 20 | Axial piston variable double pump
Through drive dimensions
Through drive dimensions
Flange SAEJ744
1)
Hub for splined shaft
2)
Diameter Mounting
3)
Code Diameter Code 045 035
Without through drive ● ● 0000
82-2 (A)
A2 5/8 in 9T 16/32DP S2 ● ● A2S2
A2 3/4 in 11T 16/32DP S3 ● ● A2S3
A2 7/8 in 13T 16/32DP S4 ● ● A2S4
101-2 (B)
B2 7/8 in 13T 16/32DP S4 ● ● B2S4
B2 1 in 15T 16/32DP S5 ● ● B2S5
▼ 101-2 ▼ 82-2
146
391.7
From mounting
flange
10
101.6 H7(
+0.035
)
0
106.4
82.55 H7(
+0.025
)
0
391.7
From mounting
flange
7.5
Overview of attachment options
Through drive Attachment option−additional pumps
Flange Hub for splined shaft Code A10VG
NG (shaft)
A10V(S)O/5x
NG (shaft)
External gear pump
6)
82-2 (A) 5/8 in A2S2 — 10, 18 (U) AZPF, AZPS NG4 … 28
AZPW NG5 … 22
101-2 (B) 7/8 in B2S4 18 (S) 28(S)
45 (U)
—
1 in B2S5 28, 45 (S) 45 (S)
60 (U)
—
Combination pumps
By using combination pumps, it is possible to have inde-
pendent circuits without the need for splitter gearboxes.
When ordering combination pumps, the type designations
of the 1st and 2nd pump must be linked by a "+".
Ordering example
A21VG45ET1PD0/10AR + AZPN....
The A21VG variable double pump is permissible without
additional supports where the dynamic mass acceleration
does not exceed maximum 10g(=98.1m/s
2
). When
mounting another pump on the A21VG, the mounting
ange must be rated for the permissible mass torque.
1) The through-drive ange is only supplied with the fastening
thread corresponding to the ordering code designation.
2)
According to ANSI B92.1a, 30° pressure angle, at root, side t,
tolerance class 5
3) Mounting drillings pattern viewed on through drive, with control
at top
4) Thread according to ASME B1.1,
for notes on tightening torques, see instruction manual
5) O-ring included in the scope of delivery
6) Bosch Rexroth recommends special versions of the external
gear pumps. Please contact us.
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
High-pressure relief valves
21
High-pressure relief valves
The four high-pressure relief valves protect the hydrostatic
transmission (pump and motor) from overload. They limit
the maximum pressure in the respective high-pressure line
and serve simultaneously as boost valves.
High-pressure relief valves are not working valves and are
only suitable for pressure spikes or high rates of pressure
change.
Setting the valves
p
Sp
q
v1
(n
= 1000 min
-1
)
q
v max
(n
= n
max
)
p
Sp
p
max
≥ 30 bar
Operating pressure p
A, B
at port A, B
Δp Drive
design
Differential pressure Δp
HD
HD valve setting
Boost pressure
Safety
▶ The valve settings are preset and the cracking pressures
may have deviations due to changes in the operating
parameters.
▶ The differential pressure setting is preset in therange
Δp=250to420bar in increments of 10bar.
▶ When ordering, state differential pressure setting in
plain text.
Settings on high-pressure relief valve A and B
(Pump 1 and 2)
Differential pressure setting
Δp
HD
= 420 bar
Cracking pressure of the HD valve (at q
V 1
)
(p
max
= Δp
HD
+ p
Sp
)
p
max
= ... bar
Bosch Rexroth Corporation, RE-A93224/2025-02-12
22 A21VG series 20 | Axial piston variable double pump
Mechanical stroke limiter
Mechanical stroke limiter
The mechanical stroke limiter is an additional function
allowing the maximum displacement of the pump to be
steplessly reduced, regardless of the control module
used. Standard unit includes variable mechanical stroke
limiters on both sides of the pump so that maximum
displacement can be limited for any of the outlet ports.
Dimensions
68.5
max.
111
R
X
1
X
2
R
113.3 278.6
▼ Schematic
A
A
B
B
X1
X2
G
R
T1
X1
X2
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Pilot shut-off valve (Neutral valve)
23
Pilot shut-off valve (Neutral valve)
Actuation of the switching solenoid enables pilot pressure
to ow through to the control device of the front and rear
pump. When the solenoid is de-energized, this connection
is interrupted and the pilot pressure to the control devices
is relieved to the pump housing. This ensures the pump is
torque-free and the swash plate returns to neutral position
(no ow condition).
Another function of the pilot shutoff valve is that it can be
also used as a brake release valve. The YBR port can be
used to send pressure signal to release the brakes when
the solenoid is energized. In the de-energized state, the
brake release pressure will be relieved to the pump housing.
Dimensions
118.2
191.1
32.2
182.6
42
45.5
215.1
Y
BR
P
S
Technical Data
Voltage 12V 24 V
Neutral position Vg = 0 de-energized de-energized
Position Vg max Current switched on Current switched on
Nominal resistance (at 20 °C) 7.4 Ω (±7%) 28.4 Ω (±7%)
Nominal power 20 W 20 W
Nominal current 1.04 A 0.54 A
Max. current 1.67 A 0.83 A
Bosch Rexroth Corporation, RE-A93224/2025-02-12
24 A21VG series 20 | Axial piston variable double pump
Pilot shut-off valve (Neutral valve)
▼ Schematic
A
A
B
B
X1 X2
Ps G
U
R
T1
U
X1 X2
b
a
a
b
YBR
Port for Standard Size (in) State
Y
BR
Pressure port for auxiliary circuit ISO 11926 9/16-18 UNF-2B 13 deep Plugged
P
S
Pressure port for auxiliary circuit ISO 11926 9/16-18 UNF-2B 13 deep Plugged
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
DA−Control valve, xed setting
25
DA−Control valve, xed setting
Speed related pilot pressure supply
The DA closed loop control is an engine speed-dependent
system for travel drives. The built-in DA control valve
generates a pilot pressure which is proportional to pump
(engine) drive speed. The pump displacement is innitely
variable in each ow direction and is inuenced by both
pump drive speed and system pressure.
Increasing the pump drive speed causes the DA control
valve to generate a higher pilot pressure with a resulting
increase in the ow from the pump. Depending on the
selected pump operating characteristics, increasing sys-
tem pressure (e.g. machine load) causes the pump to
swivel back towards a smaller displacement. Diesel engine
overload protection (anti-stall) is achieved by the combi-
nation of this pressure-related pump de-stroking, and the
reduction of pilot pressure as the engine speed drops.
Any additional power requirement, e.g. for hydraulic func-
tions from attachments, could cause the engine speed to
drop further. This would cause a further reduction in pilot
pressure and thus of pump displacement. Automatic
power distribution and full exploitation of the available
power are achieved in this way, both for the travel drive
and for the implement hydraulics, with priority given to
the implement hydraulics.
The DA control valve can also be used in pumps with EP,
HT and HW control modules to protect the combustion
engine against overload. DA closed loop control is only
suitable for certain types of drive systems and requires
review of the engine and vehicle parameters to ensure that
the pump is used correctly and that machine operation is
safe and efcient. We recommend that all DA applications
be reviewed by a Bosch Rexroth application engineer.
Dimensions
86
110.1
191.1
186.2
38
30
Y
G
1
Bosch Rexroth Corporation, RE-A93224/2025-02-12
26 A21VG series 20 | Axial piston variable double pump
DA−Control valve, xed setting
▼ Schematic
A
A
B
B
X1 X2
G1
Y
G
R
T1
X1 X2
Port for Standard Size State
G
1
Boost pressure, inlet ISO 11926 3/4-16 UNF-2B 13 deep Open
Y Pilot pressure, outlet ISO 11926 9/16-18 UNF-2B 13 deep Open
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Swivel angle sensor
27
Swivel angle sensor
For the swivel angle indicator, the pump swivel angle is
measured by an electric swivel angle sensor. As an output
parameter, the Hall-effect swivel angle sensor delivers a
voltage proportional to the swivel angle (see table of
output voltages). Please contact us if the swivel angle
sensor is used for control.
Characteristics
Supply voltage U
b
4.75 to 5.25V DC
Output voltage U
a
Ch1, Pin 4: 0.7V 2.5V 4.3V
Ch2, Pin 1: 4.3V 2.5V 0.7V
Reverse polarity protection Short circuit-resistant
Under voltage detection 3.75 to 4.05 V DC
Over voltage limit (48h max for life) 28V
EMC resistance Details on request
Operating temperature range -40 °C to +125 °C
Vibration resistance ISO 16750-3 5 to 2000 Hz
Shock resistance DIN EN 60068-2-27 25g
Salt spray resistance
DIN EN 60068-2-11
240h
Type of protection ISO 20653 (with
plugged mating connector and cable)
IP6kx, IPX6, IPx7 and
IPX9k
Housing material Plastic
Reference: RE95161
Output voltage
Direction
of rotation
Flow direction
1)
Output voltage
cw B to A > 2.5 V
A to B < 2.5 V
ccw A to B > 2.5 V
B to A < 2.5 V
▼ Schematic
A
A
B B
X1 X2
G
R T1
X1 X2
b
a
a
b
Electric swivel angle sensorElectric swivel angle sensor
Dimensions
1 2 3 4
1 = Output 2
2 = Supply Voltage
3 = Ground
4 = Output 1
Parts view V to scale
connector 4POS, MCON 1.2
View W
W
278.6
YY
103.6
106.3
▼ Mating connector set
Item Designation
1 4POS, MCON 1.2 CB REC 2p TL SEALED
2 MCON 1.2 CB REC SWS SN
3 Wire seal, rubber, red
4 Plug, blue
Reference: RE95161
The mating connector is not included in the scope of
delivery. This can be supplied by Bosch Rexroth on
request (material number R917012863).
1) For ow direction, see controls
Bosch Rexroth Corporation, RE-A93224/2025-02-12
28 A21VG series 20 | Axial piston variable double pump
Connector for solenoids
Connector for solenoids
DEUTSCH DT04-2P-EP04
Molded, 2-pin, without bidirectional suppressor diode.
There is the following type of protection with mounted
mating connector:
▶ IP67 (DIN/EN 60529) and
▶ IP69K (DIN 40050-9)
▼ Circuit symbol
▼ Mating connector DEUTSCH DT06-2S-EP04
Consisting of DT designation
1 housing DT06-2S-EP04
1 wedge W2S
2 sockets 0462-201-16141
The mating connector is not included in the scope of deliv-
ery. This can be supplied by Bosch Rexroth on request
(material number R902601804).
Note
▶ If necessary, you can change the connector orienta-
tion by turning the solenoid housing.
▶ Refer to the instruction manual for the procedure.
Installation dimensions for coupling assembly
To ensure that rotating components (coupling hub) and
xed components (housing) do not come into contact
with each other, the installation conditions described in
the installation drawing must be observed. This depends
on the size and the splined shaft.
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Installation instructions
29
Installation instructions
General
During commissioning and operation, the axial piston unit
must be lled with hydraulic uid and air bled. This must
also observed following a relatively long standstill as the
axial piston unit may drain back to the reservoir via the
hydraulic lines.
The leakage in the housing must be directed to the reser-
voir via the highest drain port T. For combinations of
multiple units, the leakage must be drained at each pump.
If a shared drain line is used for this purpose, make cer-
tain that the respective case pressure is not exceeded. In
the event of pressure differences at the drain ports of the
units, the shared drain line must be changed so that the
minimum permissible case pressure of all connected units
is not exceeded in any situation. If this is not possible,
separate drain lines must be laid if necessary.
To achieve favorable noise values, decouple all connecting
lines using elastic elements and avoid above-reservoir
installation. In all operating conditions, the suction and
drain lines must ow into the reservoir below the mini-
mum uid level. The permissible suction height h
S
results
from the overall loss of pressure; it must not, however, be
higher than h
Smax
=800 mm. The minimum suction pres-
sure at port S must also not fall below 0.8bar absolute
during operation (cold start 0.5bar absolute).
When designing the reservoir, ensure adequate space
between the suction line and the drain line. This prevents
the heated, return ow from being drawn directly back
into the suction line.
Installation position
See the following examples 1 to 4.
Further installation positions are possible upon request.
Notes
▶ If it is not possible to ll the stroking chambers via
X
1
to X
2
in the nal installation position, this must
be done prior to installation.
▶ To prevent unexpected actuation and damage, the
stroking chambers must be air bled via ports X
1
or
X
2
depending on the installation position.
▶ In certain installation positions, an inuence on the
control characteristics can be expected. Gravity,
dead weight and case pressure can cause minor
shifts in control characteristics and changes in
response time.
Key
L Filling / air bleed
R Air bleed port
S Suction port
T Drain port
SB Bafe (bafe plate)
h
t min
Minimum required immersion depth (200 mm)
h
min
Minimum required distance to reservoirbottom(100mm)
h
S max
Maximum permissible suction height (800mm)
Bosch Rexroth Corporation, RE-A93224/2025-02-12
30 A21VG series 20 | Axial piston variable double pump
Installation instructions
Below-reservoir installation (standard)
Below-reservoir installation means that the axial piston
unit is installed outside of the reservoir below the mini-
mum uid level.
Installation position Air bleed
the
housing
Air bleed
the stroking
chamber
Filling
1 Without boost pump R X
1
, X
2
T
+ X
1
+ X
2
T
X
1
, X
2
X
2
, R, X
1
h
t min
h
min
SB
2 Without boost pump – – T
T
h
t min
h
min
SB
Above-reservoir installation
Above-reservoir installation means that the axial piston
unit is installed above the minimum uid level of the
reservoir. Observe the maximum permissible suction
height h
S max
= 800 mm.
Installation position Air bleed
the
housing
Air bleed
the stroking
chamber
Filling
3 Without boost pump R X
1
, X
2
L
1
+ X
1
+ X
2
X
1
, X
2
X
2
, R, X
1
L
1
SB
T
h
t min
h
min
4 Without boost pump L
1
– L
1
h
t min
h
min
L
1
SB
T
For legend and notes, see page Page 29.
RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Project planning notes
31
Project planning notes
▶ The pump A21VG is designed to be used in closed
circuit.
▶ The project planning, installation and commissioning
of the axial piston unit requires the involvement of
qualied skilled personnel.
▶ Before using the axial piston unit, please read the
corresponding instruction manual completely and
thoroughly. If necessary, these can be requested from
BoschRexroth.
▶ Before nalizing your design, please request a binding
installation drawing.
▶ The specied data and notes contained herein must
be observed.
▶ Depending on the operating conditions of the axial
piston unit (working pressure, uid temperature),
thecharacteristic curve may shift.
▶ Preservation: Our axial piston units are supplied as
standard with preservative protection for a maximum
of 12 months. If longer preservative protection is
required (maximum 24 months), please specify this in
plain text when placing your order. The preservation
periods apply under optimal storage conditions, details
of which can be found in the data sheet 90312 or the
instruction manual.
▶ Not all versions of the product are approved for use
in a safety function according to ISO13849. Please
consult the responsible contact person at Bosch
Rexroth if you require reliability parameters (e.g. MTTF
d
)
for functional safety.
▶ Depending on the type of control used, electromag-
netic effects can be produced when using solenoids.
When a direct current is applied, solenoids do not
cause electromagnetic interference nor is their opera-
tion impaired by electromagnetic interference. Other
behavior can result when a modulated direct current
(e.g. PWM signal) is applied. Potential electromagnetic
interference for persons (e.g. persons with a pace-
maker) and other components must be tested by the
machine manufacturer.
▶ The pressure cut-off is not a safeguard against pressure
overload. Be sure to add a pressure relief valve to the
hydraulic system.
▶ Please note the details regarding the tightening torques
of port threads and other threaded joints in the
instruction manual.
▶ Working ports:
– The ports and fastening threads are designed for
the specied maximum pressure. The machine or
system manufacturer must ensure that the connect-
ing elements and lines correspond to the specied
application conditions (pressure, ow, hydraulic
uid, temperature) with the necessary safety fac-
tors.
– The working ports and function ports are only
intended to accommodate hydraulic lines.
32
Bosch Rexroth Corporation, RE-A93224/2025-02-12
A21VG series 20 | Axial piston variable double pump
Safety instructions
Bosch Rexroth Corporation
Hydraulics
8 Southchase Court
Fountain Inn, SC 29644-9018
Telephone (864) 967-2777
Facsimile (864) 962-5338
www.boschrexroth-us.com
© 2024 Bosch Rexroth Corporation
This document, as well as the data, specifications and other information set
forth in it, are the exclusive property of Bosch Rexroth Corporation. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The information given does not release the user
from the obligation of own judgment and verification. It must be remembered
that our products are subject to a natural process of wear and aging.
Subject to change.
Safety instructions
▶ During and shortly after operation, there is a risk of
getting burnt on the axial piston unit and especially
on the solenoids. Take appropriate safety measures
(e.g. by wearing protective clothing).
▶ Moving parts in control equipment (e.g. valve spools)
can, under certain circumstances get stuck in position
as a result of contamination (e.g. impure hydraulic
uid, abrasion, or residual dirt from components).
As a result, the hydraulic uid ow and the build-up of
torque in the axial piston unit can no longer respond
correctly to the operator's specications. Even the use
of various lter elements (external or internal ow
ltration) will not rule out a fault but merely reduce
the risk. The machine/system manufacturer must test
whether remedial measures are needed on the machine
for the application concerned in order to set the con-
sumer being driven to a safe position (e.g. safe stop)
and if necessary to ensure it is properly implemented.
▶ Moving parts in high-pressure relief valves may in
certain circumstances become stuck in an undened
position due to contamination (e.g. impure hydraulic
uid). This can result in restriction or loss of the load
holding function in lifting winches. The machine/system
manufacturer must check whether additional measures
are required on the machine for the relevant applica-
tion in order to keep the load in a safe position and
ensure they are properly implemented.