RE-A93224/2025-02-12, Bosch Rexroth Corporation
Axial piston variable double pump | A21VG series 20
Project planning notes
31
Project planning notes
▶ The pump A21VG is designed to be used in closed
circuit.
▶ The project planning, installation and commissioning
of the axial piston unit requires the involvement of
qualied skilled personnel.
▶ Before using the axial piston unit, please read the
corresponding instruction manual completely and
thoroughly. If necessary, these can be requested from
BoschRexroth.
▶ Before nalizing your design, please request a binding
installation drawing.
▶ The specied data and notes contained herein must
be observed.
▶ Depending on the operating conditions of the axial
piston unit (working pressure, uid temperature),
thecharacteristic curve may shift.
▶ Preservation: Our axial piston units are supplied as
standard with preservative protection for a maximum
of 12 months. If longer preservative protection is
required (maximum 24 months), please specify this in
plain text when placing your order. The preservation
periods apply under optimal storage conditions, details
of which can be found in the data sheet 90312 or the
instruction manual.
▶ Not all versions of the product are approved for use
in a safety function according to ISO13849. Please
consult the responsible contact person at Bosch
Rexroth if you require reliability parameters (e.g. MTTF
d
)
for functional safety.
▶ Depending on the type of control used, electromag-
netic effects can be produced when using solenoids.
When a direct current is applied, solenoids do not
cause electromagnetic interference nor is their opera-
tion impaired by electromagnetic interference. Other
behavior can result when a modulated direct current
(e.g. PWM signal) is applied. Potential electromagnetic
interference for persons (e.g. persons with a pace-
maker) and other components must be tested by the
machine manufacturer.
▶ The pressure cut-off is not a safeguard against pressure
overload. Be sure to add a pressure relief valve to the
hydraulic system.
▶ Please note the details regarding the tightening torques
of port threads and other threaded joints in the
instruction manual.
▶ Working ports:
– The ports and fastening threads are designed for
the specied maximum pressure. The machine or
system manufacturer must ensure that the connect-
ing elements and lines correspond to the specied
application conditions (pressure, ow, hydraulic
uid, temperature) with the necessary safety fac-
tors.
– The working ports and function ports are only
intended to accommodate hydraulic lines.