Load sensing pre-compensated directional control valve | RM10-MPP & RM15-MPP
Ordering code
7
RA64955/2023-09-20, Bosch Rexroth Corporation
ORDERING CODE
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
RM
–
S 1 / S Z ZZ
– – –
Z Z
– –
S 00
Spool conguration
10 Closed center spool E
Motor spool J
Float spool W
Spool ow – Liters Per Minute (lpm) A – B
11-12
RM10 E spools 1:1 symmetric ratio
1.3 – 1.3 GPM 005* – 005*
5.3 – 5.3 GPM 020 – 020
7.9 – 7.9 GPM 030 – 030
10.6 – 10.6 GPM 040 – 040
17.2 – 17.2 GPM 065 – 065
23.8 – 23.8 GPM 090 – 090
RM15 E spools 1:1 symmetric ratio
29.1 – 29.1 GPM 110 – 110
34.3 – 34.3 GPM 130 – 130
39.6 – 39.6 GPM 150 – 150
RM10 E spools 1:1.5 asymmetric ratio
7.9 – 5.3 GPM 030 – 020
10.6 – 7.1 GPM 040 – 027
17.2 – 11.4 GPM 065 – 043
23.8 – 15.9 GPM 090 – 060
RM15 E spools 1:1.5 asymmetric ratio
29.1 – 19.3 GPM 110 – 073
30.4 – 23.0 GPM 115 – 087
34.3 – 23.0 GPM 135 – 095
39.6 – 26.4 GPM 150 – 100
RM10 J spools 1:1 symmetric ratio
6.6 – 6.6 GPM 025 – 025
10.6 – 10.6 GPM 040 – 040
17.2 – 17.2 GPM 065 – 065
23.8 – 23.8 GPM 090 – 090
RM15 J spools 1:1 symmetric ratio
29.1 – 29.1 GPM 110 – 110
30.4 – 30.4 GPM 115 – 115
35.7 – 35.7 GPM 135 – 135
39.6 – 39.6 GPM 150 – 150
W spools, A side 4
th
position oat A (power) – B
RM10 MPP 7.9 – 18.5 GPM 030 – 070
RM15 MPP 10.6 – 23.8 GPM 040 – 090
A side actuations
13 DT04-2P (Deutsch) 12V proportional electric pilot D1
DT04-2P (Deutsch) 24V proportional electric pilot D2
Junior Timer 2-pin (AMP) 12V proportional electric pilot J1
Junior Timer 2-pin (AMP) 24V proportional electric pilot J2
Hydraulic pilot (Port type determined by 04) HP
A side actuation additional options
14 None Z
Ordering Code continued on next page.