Commissioning
Before commissioning, check that
– all connections fit properly and do not show any defects,
– the base plate was mounted stress-free on the tank,
– a filter element was inserted in the return flow filter,
– a tank breather filter or a level / temperature measuring device is installed.
Port D – variants with clogging indicator:
The technical connection data for clogging indicator type ..RV2.. and
type ..E2SPSS.. can be found on pages 5, 10 and 11, and data sheet RE 50088.
Installation notes
– Ensure sufficient distance to the tank wall and components
– Ensure free access to ports for the return flow filter, sample-taking and port E
– Make sure that there is sufficient space upwards for changing the filter elements
– The return flow filter can be connected to T1, T2 or T3
– The pressure measuring fitting with the sample-taking tube can be connected to X1 or X3
Electrical connections:
– Electrical connections may only be established by specialist personnel
– Before working on electrical components, interrupt the power supply
– After having connected the circular plug-in connection M12 x 1 tighten it my means of screws
– Only connect the circular plug-in connection M12 x 1 when disconnected from the power supply
– Do not overload contacts (see Technical data)
– In the case of inductive load, provide protective circuit!
Note
The electronic clogging indicator is provided with an illuminated circle of LEDs which is visible from all directions. These LEDs sig-
nal, apart from usual status messages, additional fault messages.
If the switching outputs were activated due to excessive pressure, they can only be deactivated by switching the system off or
when the hydraulic fluid temperature falls again below 20 °C.
To trigger a switching process, the pressure must have exceeded the corresponding limit value (2.2 or 2.9 bar) without any inter-
ruption. This prevents the alarm from being triggered by brief pressure peaks.
Press the reset key after each filter change!
Green LED permanently ON Supply voltage is applied and device is ready
Yellow LED permanently ON Switching output 1 is closed (alarm at 2.2 bar)
Red LED permanently ON Switching output 2 is open (alarm at 2.9 bar)
Green LED flashes about 2x per second
Temperature < 30 °C (switching outputs not enabled)
Red LED
flashes about 2x per second
Pressure or temperature sensor defective,
switching output 2 is open.