Bosch Rexroth AG
Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
Fax +49 (0) 93 52 / 18-23 58
documentation@boschrexroth.de
www.boschrexroth.de
© This document, as well as the data, specifications and other information
set forth in it, are the exclusive property of Bosch Rexroth AG. It may not
be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No state-
ments concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process of
wear and aging.
8/8 Bosch Rexroth AG Hydraulics
ABZMS-35
RE 50212/04.07
Installation notes
1
Cable
2
Isolating relay
–
Vertical installation according to technical data on page 3
–
Avoid flows
– Do not expose switches to strong impacts and excessive bending.
–
Avoid external magnetic fields. These could impair the function of the reed contacts.
Electrical connections:
–
Electrical connections may only be established by specialist personnel
– Tighten circular plug-in connectors M12x1 and female connectors after their connection
– Plug circular plug-in connectors M12x1 and female connectors only when disconnected from the power supply
–
Do not overload contacts (see technical data)
–
In the case of inductive loads, provide suppressor circuit!
According to DIN EN 50020 float switches are simple electrical apparatus, which are not provided with voltage sources.
The electrical components consist of reed contacts, bimetal thermostats, plug-in connections and terminals.
The equipment complies with construction regulations according to DIN EN 60079-0 and DIN EN 50020.
According to DIN EN 60079-14 these simple, electrical apparatus may be used in intrinsically safe electric circuits [EEx ib] in sys
-
tems for equipment class II, category 2G (Zone 1) and category 3G (Zone 2) without marking and certification.
The apparatus are assigned to category ib and temperature class T6.
Use in potentially explosive atmospheres according to Directive 94/9/EC (ATEX)
Intrinsically safe, electrical equipment in
potentially explosive
atmosphere (zone 1 and 2)
Associated electrical
equipment in safe zone
Normative cross-reference
DIN EN 50020 Electrical apparatus for potentially explosive
atmospheres - intrinsic safety “i“;
German version of EN 50020:2002
DIN EN 60079-0
Electrical apparatus for explosive gas
atmospheres - Part 0: General requirements
(IEC 60079-0:2004);
German version of EN 60079-0:2004
DIN EN 60079-14 Electrical apparatus for explosive gas
atmospheres - Part 14: Electrical installa-
tions in hazardous areas (other than mines)
(IEC 60079-14:2002); German version of
EN 60079-14:2003
DIN EN 175201-804
Detail specification - round connectors -
circular contacts, size diameter 1.6 mm;
threaded coupling; German version of
EN 175201-804:1999
DIN EN 175301-803
Detail specification: Rectangular connectors
- flat contacts 0.8 mm thickness - locking
screw not detachable;
German version EN 175301-803:1999