28/32 DBA, DBAW, DBAE(E), DBAEA | Pump safety block
BoschRexrothAG, RE25891, edition: 2021-08
Safety instructions: Type-examination tested safety valves typeDBA…E, component series 2X
according to Pressure Equipment Directive 2014/68/EU
▶ Before ordering atype-examination tested safety valve,
it must be observed that for the desired response
pressure p, the maximum admissible ow q
Vmax
must be larger than the maximum possible flow of
the system to be secured.
In this respect, the applicable regulations
must be observed.
▶ According to PED 2014/68/EU, the increase in the
system pressure due to the flow must not exceed 10%
of the set response pressure (seecomponent marking).
▶ The maximum admissible flow stated in the component
marking q
Vmax
(=numerical value instead of the
character "G" in the component marking,
seepage27) must not be exceeded.
▶ Discharge lines of safety valves must end in arisk-free
manner. The accumulation of fluids in the discharge
lines must not be possible.
▶ If alead seal at the safety valve is removed,
the approval according to the PED becomes void.
▶ The requirements of the Pressure Equipment Directives
2014/68/EU and of datasheetAD2000 A2 must be
generally observed.
▶ Options DBAE/DBAEE or 2./3. pressure limiting function
(
6
) are only possible for pressure relief valves
for variable displacement pumps (also seepage3).
▶ The relief function (DBAW../DBAE../DBAEE..) must not
be used for safety functions.
▶ Possible relief via the directional valve must not be
applied for safety-relevant functions. If relief is required
for safety-relevant functions, an additional safety valve
must be installed.
Application notes must always be observed
▶ In the plant, the response pressure specified in the
component marking is set with aflow of 11l/min.
▶ The maximum admissible flow stated in the
component marking applies for applications without
counter pressure in the discharge line (port T).
Notice:
The system pressure increases by the counter
pressure in the discharge line (port T) with increasing
flow (observe AD2000 - datasheetA2 - item 6.3).
To ensure that this increase in system pressure
caused by the flow does not exceed 10% of the set
response pressure, the admissible flow has to be
reduced according to the counter pressure in the
discharge line (port T) (seefollowing diagrams
on pages 29 and 30).
Deviating technical data: Type-examination tested safety valve typeDBA…E,
Component series 2X, according to the Pressure Equipment Directive2014/68/EU
Hydraulic
Maximum flow seeordering code on page27 and diagrams on page29 and 30
Hydraulic fluid Mineral oil (HL, HLP) according to DIN51524-1 and DIN51524-2
Hydraulic fluid temperature range (=TS) °C –10 … +80
Viscosity range mm
2
/s 12 … 230