RE 18323-38/03.2023, Bosch Rexroth Oil Control S.p.A.
Solenoid operated valves pilot operated poppet type
2-way normally open
Special cavity, 021-E
RE 18323-38
Edition: 03.2023
Replaces: 03.2021VEI-16-021-NA OD.15 - X - 21 - Y - Z- 00
Technical data
General
Weight 0.35kg (0.77lbs)
Installation orientation Unrestricted
Storage ambient temperature range -40 to 100°C (-40 to 212°F)
Operating ambient temperature range -30 to 90°C (-22 to 194°F)
Salt spray test to
DIN EN ISO 9227:2017-07
500 h
Hydraulic
Max. operating pressure 350bar (5000psi)
Flow range 5 - 150l/min (1 - 40 gpm)
Fatigue cycle life 1 million cycles at 350 bar
Max. internal leakage: 20 drops/min.
Switching time Closing ≤ 100 ms
Opening ≤ 50 ms
Fluid temperature range -20 to 80°C (-4 to 176°F)
Fluids: Mineral-based or synthetics with lubricating properties at
viscosities of 20 to 380 mm
2
/s (cSt)
Installation torque 130 - 150Nm (96 - 111ft-lbs)
Recommended degree of
fluid contamination
Nominal value max. 10µm
(NAS 8) ISO 4406 19/17/14
MTTFD 150 years see RE 18350-51
Special cavity 021-E see 18325-75
Seal kit for X=02,06 code
material no.
RG21E201052010
R934003566
Seal kit for X=04,10,12,32 code
material no.
RG21E201053010
R934003567
Seal kit coil and standard
cap
code
material no.
RG02Z0010000100
R930067869
Seal kit coil and protective
cap only for Y=B
code
material no.
RG03Z0010000100
R930067870
Seal kit coil and protective
cap only for Y=C
code
material no.
RG04Z0010000100
R930069171
Other technical data See data sheet 18350-50
Electrical
Type of voltage DC voltage
Coil type D36
Supply voltage See data sheet 18325-90
Voltage tolerance against ambient
temperature
See characteristic curve
Power consumption 20W
Type of protection See data sheet 18325-90
Note: Coils must be ordered separately
Technical data
New VEI-16 family incorporates a new solenoid concept
providing excellent performance and enables cartridges to
work in severe environment. Cartridges also incorporates
advanced design of hydraulic parts providing excellent
hydraulic performance.
PATENT PENDING