File: XD3002_E 08/2010/eVIII • 2
8
I (%)
Q (l/min)
I (%)
Q (l/min)
I (%)
Q (l/min)
I (%)
Q (l/min)
XD.3.*.01.N
(3 l/min P
→ →
→ →
→ A/B)
XD.3.*.01.N
(10 l/min P
→ →
→ →
→ A/B)
XD.3.*.01.N
(15 l/min P
→ →
→ →
→ A/B)
XD.3.*.01.N
(18 l/min P
→ →
→ →
→ A/B)
XD.3.A.01.N.. XD.3.A.03.N.. XD.3.C.01.N.. XD.3.C.03.N..
XD.3.A.01.P.. XD.3.A.03.P.. XD.3.C.01.P.. XD.3.C.03.P..
XD.3.A.01.T.. XD.3.A.03.T.. XD.3.C.01.T.. XD.3.C.03.T..
Q (l/min)
P (bar)
XD.3.A... / XD.3.C... SOLENOID OPERATING
PROPORTIONAL
VALVES
CETOP 3
POWER LIMITS TRANSMITTED
P
→→
→→
→A / B
→→
→→
→T
OR P
→→
→→
→B / A
→→
→→
→T
INPUT SIGNAL CURVES - FLOW RATE
XD.3.A../XD.3.C.. series valves are used for controlling fluid direction and flow rate as a
function of the supply current to the proportional control solenoid.
Any valve ∆p variation causes a change in the set flow rate; however the valve itself ensure
a high level internal compensation by limiting the controlled flow rate.
To ensures a constant flow rate and reduce leakage, we recommend to use AM3H2V or
AM3H3V hydrostats.
Performances shown in this catalogue are guaranteed only using 2 or 3 way modular
assembly hydrostats type AM.3.H. ...
The shown flow rates are typical for one line operation ( e.g. from P to B), while higher flow
rates are obtainable by using the valve with our flow rate doubling sub-base type BC.3.07 (see
diagram next page). This type of configuration extends considerably the flow rate limit.
XD Proportional valve
3 CETOP 3/NG6
* A = Single solenoid
C = Double solenoid
** Type of spool
01 = 03 =
* Flow path control (see symbols table)
N = symmetrical
P = meter in
T = meter out
* Flow rating
l/min (∆p 5 bar)
1 = 3 l/min
2 = 10 l/min
3 = 15 l/min
4 = 18 l/min
* E = 9VDC (2.35 A)
F = 12VDC (1.76 A)
G = 24VDC (0.88 A)
** 00 = No variant
V1 = Viton
P1 = Rotary emergency
P5 = Rotary emergency 180°
2 Serial No.
XD.3...
"D15P" PROPORT. SOLENOIDS CH. VIII PAGE 3
REM.S.RA... CH. IX PAGE 4
REM.D.RA... CH. IX PAGE 7
SE.3.AN21.00... CH. IX PAGE 11
AM.3.H... CH. VIII PAGE 16
BC.3.07... CH. VII PAGE 12
ORDERING CODE
The fluid used is a mineral based oil with a viscosity of 46 mm
2
/s at 40°C.
The tests have been carried out at with a fluid of a 40°C.
File: XD3002_E 08/2010/eVIII • 3
8
XD.3.A... OVERALL DIMENSIONS XD.3.C... OVERALL DIMENSIONS
SCHEMA FOR DOUBLE FLOW RATE
Max. operating pressure ports P/A/B 350 bar
Max. operating pressure ports T - for dynamic pressure see note (*) 250 bar
Regulated flow rate 3 / 10 / 15 / 20 / 25 l/min
Relative duty cycle Continuous 100% ED
Type of protection IP 65
Flow rate gain See diagrams
Hysteresis with connection P/A/B/T ∆p = 5 bar (P/A) ≤ 7% of max. flow rate
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -20°C ÷ 75°C
Max. contamination level class 8 in accordance with
NAS 1638 with filter ß
10
≥75
Weight XD.3.A... (single solenoid) 1,5 Kg
Weight XD.3.C... (double solenoid) 1,7 Kg
Type of voltage 9V 12V 24V
Max. current 2.35A 1.76 A 0.88 A
Solenoid coil resistance at 25°C (77°F) 2.25 Ohm 4.0 Ohm 16.0 Ohm
(*) Pressure dynamic allowed for 2 millions of cycles.
XD.3.A... / XD.3.C... SOLENOID OPERATING PROPORTIONAL VALVES CETOP 3
ELECTRONIC CONTROL UNIT
REM.S.RA.*.*. and REM.D.RA.*.*.
Card type control for single and double sole-
noid
SE.3.AN.21.00...
EUROCARD type control for single and dou-
ble solenoid
AM.3.H.2V.P1 and AM.3.H.3V.P1
Hydrostats 2 or 3 way.
XD.3.A...
BC.3.07
Standard base
• Operating specifications are valid for fluid with 46 mm
2
/s viscosity at 40°C, using
the specified ARON electronic control units.
OPERATING SPECIFICATIONS
Fixing screws UNI 5931 M5x40 (min. 8.8 material screws are recommended)
Tightening torque 4 ÷ 5 Nm / 0.4 ÷ 0.5 Kgm
Support plane
specification
"D15P" PROPORTIONAL SOLENOIDS
Type of protection (in relation to connector used) IP 66
Duty cycle 100% ED
Insulation class wire H
Weight (coil) 0,354 Kg
Weight (solenoid) 0,608 Kg
ETD15P - 01/2002/e
P1 Rotary
emergency
P5 Rotary
emergency 180°