5
HA 4024
Pilot and Drain
The RNEH valves are available with pilot and drain, both internal and external. The version with external drain allows
for a higher back pressure on the outlet.
Type of valve
Plug assembly
XY
RNEH4-25**/*
Internal pilot and external drain NO* YES
RNEH4-25**/*I
Internal pilot and internal drain NO* NO
RNEH4-25**/*E
External pilot and external drain YES YES
RNEH4-25**/*EI
External pilot and internal drain YES NO
X: plug M6 x 8 for external pilot
Y: plug M6 x 8 for external drain
* C3 version is available only with internal pilot.
Electrical Features
DC solenoid AC solenoid
Max. allowable voltage variation % -10 ... +6 ±10
Max. switching frequency 1/h 8 000
Switching times ±10 %, energizing (two position) ms 75 60
Switching times ±10 %, de-energizing (two position) ms 90 90
Switching times ±10 %, energizing (three position) ms 55 45
Switching times ±10 %, de-energizing (three position) ms 60 60
Duty cycle % 100
Enclosure type to EN 60 529 IP 65
Solenoids
The operating solenoids are DC solenoids. For AC supply the solenoids are provided with rectifier which are integrated in the
EN connector socket as part of the solenoid. The connectors can be turned by 90°. By loosening the nut, the solenoids can be
turned or replaced without interfering with any seals of the valve.
In the case of solenoid malfunction or power failure, the spool of the valve can be shifted by manual override, provided the
pressure in T-port does not exceed 25 bar.
The values indicated refer to a solenoid valve operating with piloting pressure 100 bar, with mineral oil at a temperature of
40 °C, a viscosity of 32 mm
2
/s and with PA and BT connections. The switch on times are obtained from the time the spool
switches over. The switch off times are measured at the time pressure variation occurs in the line.
Y: plug M6 x 8 for external drain