Subject to change · 40.80-e · 0215
Page 1
www.argo-hytos.com
HD 417 · HD 617
Bi-directional flow · In-line mounting · Operating pressure up to 500 bar · Nominal flow rate up to 420 l/min
High Pressure Filters
Description
Application
In the high pressure circuits of hydraulic systems with changing
flow direction.
Performance features
Protection against wear:
By means of filter elements that, in full-flow filtration, meet even
the highest demands regarding cleanliness classes.
Protection against malfunction:
Through installation near to the control valves or other expensive
components. The specific determined flow rate guarantees a
closed by-pass valve even at ν ≤ 200 mm
2
/s (cold start condition).
Special features
Reverse flow valves:
The “Graetz” system (see Symbols) integrated into the head
piece ensures the filtration of the hydraulic fluid in both flow
directions.
Filter elements
Flow direction from outside to centre. The star-shaped pleating
of the filter material results in:
› large filter surfaces
› low pressure drop
› high dirt-holding capacities
› long service life
Filter maintenance
By using a clogging indicator the correct moment for main-
tenance is stated and guarantees the optimum utilization of the
filter life.
Materials
Filter head: Spheroidal graphite cast iron (SGI)
Filter bowl: Cold extruded steel
Coating: Powder paint
Seals: NBR (FPM on request)
Filter media: EXAPOR
®
MAX 2 - inorganic multi-layer
microfibre web
Paper - cellulose web, impregnated with
resin
Accessories
Electrical and/or optical clogging indicators are available -
optionally with one or two switching points resp. temperature
suppression.
Dimensions and technical data see catalogue sheet 60.30.
High Pressure Filter HD 417
Subject to change · 40.80-e· 0215
Page 2
www.argo-hytos.com
Characteristics
Operating pressure
0 ... 315 bar, min. 2 x 10
6
pressure cycles
Nominal pressure according to DIN 24550
0 ... 500 bar, min. 10
4
pressure cycles
Quasi-static operating pressure
Permissible pressures for other numbers of cycles
Number of cycles n
Operating pressure p [bar]
Nominal flow rate
Up to 420 l/min (see Selection Chart, column 2)
The nominal flow rates indicated by ARGO-HYTOS are based on
the following features:
› closed by-pass valve at ν ≤ 200 mm
2
/s
› element service life > 1000 operating hours at an average
fluid contamination of 0,07 g per l/min flow volume
› flow velocity in the connection lines:
up to 250 bar ≤ 8 m/s
> 250 bar ≤ 12 m/s
Filter fineness
5 µm(c) ... 30 µm(c)
β-values according to ISO 16889
(see Selection Chart, column 4 and diagram Dx)
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Chart, column 5)
Hydraulic fluids
Mineral oil and biodegradable fluids
(HEES and HETG, see info-sheet 00.20)
Temperature range
-30 °C ... +100 °C (temporary -40 °C ... +120 °C )
› at operating temperature:ν < 60 mm
2
/s
› as starting viscosity: ν
max
= 1200 mm
2
/s
› at initial operation:
The recommended starting viscosity can be read from the
diagram D (pressure drop as a function of the kinematic
viscosity) as follows: Find the 70 % ∆p of the cracking
pressure of the by-pass valve on the vertical axis. Draw a
horizontal line so that it intersects the ∆p curve at a point.
Read this point on the horizontal axis for the viscosity.
Mounting position
Preferably vertical, filter head on top
Connection
SAE-flange (6000 psi). Sizes see Selection Chart, column 6
(other connections on request)
Diagrams
∆p-curves for complete filters in Selection Chart, column 3
D1
Pressure drop as a function of the flow volume at ν = 35 mm
2
/s, measurement with reverse flow valves, (0 = casing empty)
0
4
2
6
HD 417
1
2
3
4
5+6
0
100 200 300 400 500
∆p [bar]
Q [l/min]
0
4
2
6
HD 617
1
2
3
4
5+6
0
100 200
300
400 500
∆p [bar]
Q [l/min]
Subject to change · 40.80-e · 0215
Page 3
www.argo-hytos.com
D2
Pressure drop as a function of the flow volume at ν = 35 mm
2
/s, measurement without reverse flow valves, (0 = casing empty)
0
1,0
0,5
1,5
HD 417
1
2
3
4
5+6
0
100 200 300 400 500
∆p [bar]
Q [l/min]
0
1,0
0,5
1,5
HD 617
1
2
3
4
5+6
0
100 200 300 400 500
∆p [bar]
Q [l/min]
D3
Pressure drop as a function of the kinematic viscosity at nominal flow, measurement without reverse flow valves
0
2
4
6
8
10
12
HD 417
1+3
2
2
4
5
5
6
200 400 600
800
1000
∆p [bar]
v [mm
2
/s]
0
2
4
6
8
10
12
HD 617
1
3
2
4
5
6
200 400 600
800
1000
∆p [bar]
v [mm
2
/s]
Dx
Filter fineness curves in Selection Chart, column 4
Filtration ratio β as a function of particle size x obtained
by the Multi-Pass Test according to ISO 16889
The abbreviations represent the following β-values resp.
finenesses:
For EXAPOR
®
MAX2 and Paper elements:
5EX2 = β
5 (c)
= 200 EXAPOR
®
MAX 2
7EX2 = β
7 (c)
= 200 EXAPOR
®
MAX 2
10EX2 = β
10 (c)
= 200 EXAPOR
®
MAX 2
16EX2 = β
16 (c)
= 200 EXAPOR
®
MAX 2
30P = β
30 (c)
= 200 Paper
Based on the structure of the filter media of the 30P paper
elements, deviations from the printed curves are quite probable.
For screen elements:
40S = screen material with mesh size 40 µm
60S = screen material with mesh size 60 µm
100S = screen material with mesh size 100 µm
Tolerances for mesh size according to DIN 4189
For special applications, finenesses differing from these curves
are also available by using special composed filter media.
Filtration ratio β for particles > x µm
Particle size x [µm] (for particles larger
than the given particle size x)
Efficiency [%]
Subject to change · 40.80-e· 0215
Page 4
www.argo-hytos.com
Selection Chart
Part No.
Nominal flow rate
Pressure drop see
diagram
D/
curve no.
Filter fineness see diagr.
Dx
Dirt-holding capacity
Connection A/B
Cracking pressure of by-pass
Symbol
Replacement filter element
Part No.
Weight
Clogging indicator
Remarks
l/min g bar kg
1 2 3 4 5 6 7 8 9 10 11 12
HD 417-149 150 D1,2,3/1 5EX2 29 SAE 1¼ - 3 V3.0823-13
1
20,3 optional
2
HD 417-179 220 D1,2,3/2 5EX2 33 SAE 1¼ 7 1 V3.0823-03 19,7 optional -
HD 417-146 260 D1,2,3/3 10EX2 33 SAE 1¼ - 3 V3.0823-16
1
20,3 optional
2
HD 417-176 320 D1,2,3/4 10EX2 47 SAE 1¼ 7 1 V3.0823-06 19,7 optional -
HD 417-168 350 D1,2,3/5 16EX2 48 SAE 1¼ 7 1 V3.0823-08 19,7 optional -
HD 417-161 350 D1,2,3/6 30P 26 SAE 1¼ 7 1 P3.0823-01
3
19,7 optional -
HD 617-149 220 D1,2,3/1 5EX2 41 SAE 1½ - 3 V3.0833-13
1
23,1 optional
2
HD 617-179 280 D1,2,3/2 5EX2 49 SAE 1½ 7 1 V3.0833-03 22,4 optional -
HD 617-146 320 D1,2,3/3 10EX2 49 SAE 1½ - 3 V3.0833-16
1
23,1 optional
2
HD 617-176 380 D1,2,3/4 10EX2 67 SAE 1½ 7 1 V3.0833-06 22,4 optional -
HD 617-178 420 D1,2,3/5 16EX2 68 SAE 1½ 7 1 V3.0833-08 22,4 optional -
HD 617-161 420 D1,2,3/6 30P 34 SAE 1½ 7 1 P3.0833-01
3
22,4 optional -
Optical or electrical indicators are available to monitor the clogging condition of the element. If the indicator should be already
mounted onto the filter head use the abbreviation „M“ behind the part number of the indicator. The printed order acknowledge-
ments show both items separately.
Order example: The filter HD 417-149 has to be supplied with electrical clogging indicator - cracking pressure 5,0 bar
Order description: HD 417-149 / DG 041-33 M
Part No. (Basic unit) Mounted
Clogging indicator
For the appropriate clogging indicators see catalogue sheet 60.30.
Remarks:
› Filter versions without by-pass valves must always be equipped with a clogging indicator.
› The filters listed in this chart are standard filters. Other designs available on request.
1
Element differential pressure up to 160 bar
2
Clogging indicator is obligatory
3
Paper media supported with metal gauze
Subject to change · 40.80-e · 0215
Page 5
www.argo-hytos.com
P
P
Dimensions
O
C
E
P
2
P
1
F
T
D
ØH
I
K
P
L
Q
M
N
A
G
R
S
B
V
ersion with electrical clogging indicator DG 041
Minimum distance from
ferromagnetic parts: 7 mm
Clogging indicator optional:
Pressure holes plugged with screws
Measurements
Type A/B C D E F G H I K L M
Ø/depth
N O P Q R S
Ø/depth
T
HD 417 SAE 1¼ 31,5 328 58 87,5 156 108 80 AF32 66,7 M14/22 31,8 73 102 87 100 M12/18 138
HD 617 SAE 1½ 31,5 428 58 87,5 156 108 80 AF32 79,4 M16/24 36,5 73 102 87 100 M12/18 138
Symbols
1 2 3 4
P
P
Subject to change · 40.80-e· 0215
Page 6
www.argo-hytos.com
Spare Parts
4
7 8 9 10
3
2
1
6
5
Pos. Designation Part No.
1 Filter bowl HD 417
(with Pos. 2 and 3)
HD 451.0702
1 Filter bowl HD 617
(with Pos. 2 and 3)
HD 619.0701
2 Back-ring HD 255.0102
3 O-ring 94,84 x 3,53 N007.0953
4 Filter element see Chart / col. 9
5 Hexagonal head screw M4 x 8
DIN 933-8.8
11385800
6 Bonded seal 4,1 x 7,2 x 1 12504600
7 Sleeve HD 417.0505
8 O-ring 42,52 x 2,62 N007.0433
9 Reverse flow valve HD 417.1520
10 Spring DM 38 N015.3801
Quality Assurance
Quality management according to DIN EN ISO 9001
To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to
the following ISO standards:
ISO 2941 Verification of collapse/burst pressure rating
ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 2943 Verification of material compatibility with fluids
ISO 3968 Evaluation of pressure drop versus flow characteristics
ISO 16889 Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity)
ISO 23181 Determination of resistance to flow fatigue using high viscosity fluid
Before release into the series production the filter casing is tested for fatigue strength in our pressure pulse test rig.
Various quality controls during the production process guarantee the leakfree function and solidity of our filters.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.
The functions of the complete filters as well as the outstanding
features of the filter elements assured by ARGO-HYTOS can
only be guaranteed if original ARGO-HYTOS spare parts are
used.