Subject to change · 40.70-e · 0215
Page 1
www.argo-hytos.com
HD 319 · HD 419 · HD 619
In-line mounting · Operating pressure up to 630 bar · Nominal flow rate up to 450 l/min
High Pressure Filters - Worldline 300
Description
Application
In the high pressure circuits of hydraulic systems.
Performance features
Protection against wear:
By means of filter elements that, in full-flow filtration, meet even
the highest demands regarding cleanliness classes.
Protection against malfunction:
Through installation near to the control valves or other expensive
components. The specific determined flow rate guarantees a
closed by-pass valve even at ν ≤ 200 mm
2
/s
(cold start condition).
Filter elements
Flow direction from outside to centre. The star-shaped pleating
of the filter material results in:
› large filter surfaces
› low pressure drop
› high dirt-holding capacities
› long service life
Filter maintenance
By using a clogging indicator the correct moment for main-
tenance is stated and guarantees the optimum utilization of the
filter life.
Materials
Filter head: Spheroidal graphite cast iron (SGI)
Filter bowl: Cold extruded steel
Coating: Powder paint
Seals: NBR (FPM on request)
Filter media: EXAPOR
®
MAX 2 - inorganic multi-layer
microfibre web
Accessories
If an electrical indicator is used, a transparent socket with LED
for optical indication is also available with Part No.
DG 041.1200.
High Pressure Filter HD 419
Subject to change · 40.70-e · 0215
Page 2
www.argo-hytos.com
Characteristics
Operating pressure
0 ... 360 bar, min. 2 x 10
6
pressure cycles
Nominal pressure according to DIN 24550
0 ... 630 bar, min. 10
4
pressure cycles
Quasi-static operating pressure
Permissible pressures for other numbers of cycles
Number of cycles n
Operating pressure p [bar] [bar]
Nominal flow rate
Up to 450 l/min (see Selection Chart, column 2)
The nominal flow rates indicated by ARGO-HYTOS are based on
the following features:
› closed by-pass valve at ν ≤ 200 mm
2
/s
› element service life > 1000 operating hours at an average
fluid contamination of 0,07 g per l/min flow volume
› flow velocity in the connection lines:
up to 250 bar ≤ 8 m/s
> 250 bar ≤ 12 m/s
Filter fineness
5 µm(c) ... 16 µm(c)
β-values according to ISO 16889
(see Selection Chart, column 4 and diagram Dx)
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Chart, column 5)
Hydraulic fluids
Mineral oil and biodegradable fluids
(HEES and HETG, see info-sheet 00.20).
Temperature range
-30 °C ... +100 °C (temporary -40 °C ... +120 °C)
Viscosity at nominal flow rate
› at operating temperature: ν < 60 mm
2
/s
› as starting viscosity: ν
max
= 1200 mm
2
/s
› at initial operation:
The recommended starting viscosity can be read from the
diagram D (pressure drop as a function of the kinematic
viscosity) as follows: Find the 70 % ∆p of the cracking
pressure of the by-pass valve on the vertical axis. Draw a
horizontal line so that it intersects the ∆p curve at a point.
Read this point on the horizontal axis for the viscosity.
Mounting position
Preferably vertical, filter head on top
Connection
› Threaded ports according to ISO 228 or DIN 13
› SAE-flange (6000 psi)
Sizes see Selection Chart, column 6 and ordering example
(other connections on request).
Electrical clogging indicator
› Switching voltage: max. 120 V AC / 175 V DC
› Switching current: max. 0,17 A AC / 0,25 A DC
› Switching power: max. 3,5 VA AC / 5 W DC
› Type of contact: Change over
› Electrical protection: IP 65 (with mounted and secured
socket)
Subject to change · 40.70-e · 0215
Page 3
www.argo-hytos.com
Diagrams
∆p-curves for complete filters in Selection Chart, column 3
D1
Pressure drop as a function of the
flow volume at ν = 35 mm
2
/s (0 = casing empty)
0
1,0
0,5
1,5
HD 319
1
2
4+5
6
0
3
100 200 300 400 500
∆p [bar]
Q [l/min]
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
2
4
6
8
10
12
1+3
2
5
4
6
200 400 600
800
1000
∆p [bar]
ν [mm
2
/s]
D2
Pressure drop as a function of the
flow volume at ν = 35 mm
2
/s (0 = casing empty))
0
1,0
0,5
1,5
HD 419
1
2
4+5
6
0
3
100 200 300 400 500
∆p [bar]
Q [l/min]
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
2
4
6
8
10
12
1+3
2
6
5
4
4
6
200 400 600
800
1000
∆p [bar]
ν [mm
2
/s]
D3
Pressure drop as a function of the
flow volume at ν = 35 mm
2
/s (0 = casing empty)
0
1,0
0,5
1,5
HD 619
1
2
4+5
6
0
3
100 200 300 400 500
∆p [bar]
Q [l/min]
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
2
4
6
8
10
12
1
3+5
2
6
4
6
200 400 600
800
1000
∆p [bar]
ν [mm
2
/s]
Subject to change · 40.70-e · 0215
Page 4
www.argo-hytos.com
Dx
Filter fineness curves in Selection Chart, column 4
Filtration ratio β as a function of particle size x obtained
by the Multi-Pass Test according to ISO 16889
The abbreviations represent the following β-values resp.
finenesses:
For EXAPOR
®
MAX2 and Paper elements:
5EX2 = β
5 (c)
= 200 EXAPOR
®
MAX 2
7EX2 = β
7 (c)
= 200 EXAPOR
®
MAX 2
10EX2 = β
10 (c)
= 200 EXAPOR
®
MAX 2
16EX2 = β
16 (c)
= 200 EXAPOR
®
MAX 2
30P = β
30 (c)
= 200 Paper
Based on the structure of the filter media of the 30P paper
elements, deviations from the printed curves are quite probable.
For screen elements:
40S = screen material with mesh size 40 µm
60S = screen material with mesh size 60 µm
100S = screen material with mesh size 100 µm
Tolerances for mesh size according to DIN 4189
For special applications, finenesses differing from these curves
are also available by using special composed filter media.
Filtration ratio β for particlesl > x µm
Particle size x [µm] (for particles larger
than the given particle size x)
Efficiency [%]
Two different head pieces with two various connecting options are available.
Order example: The Filter HD 319-289 has to be supplied with SAE 1¼ flanged connection.
Order descripton : HD 319-189
Connections:
2 options are available
Flanged connection (A/B) SAE 1¼ (6000 psi) 1
Threaded port (A/B) G1¼ bzw. G1½
2
2
Remarks:
› The filters listed in this chart are standard filters. If modifications are required, e.g. bolt mounted indicators according to
catalogue sheet 60.30, we kindly ask for your request.
› If an electrical indicator is used, a transparent socket with LED for optical indication is also available with Part No. DG 041.1200.
2
G1½ from series HD 619
Order Information
Subject to change · 40.70-e · 0215
Page 5
www.argo-hytos.com
Selection Chart
Part No.
Nominal flow rate
Pressure drop see
diagram
D/
curve no.
Filter fineness see diagr.
Dx
Dirt-holding capactiy
Connection A/B
Cracking pressure of by-pass
Symbol
Replacement filter element
Part No.
Weight
Clogging indicator
Cracking pressure in ( )
Remarks
l/min g bar kg bar
1 2 3 4 5 6 7 8 9 10 11 12
HD 319-289 110 D1/1 5EX2 20 G1¼ - 6 V3.0817-13
1
16,3 electrical (5) change-over
HD 319-279 155 D1/2 5EX2 24 G1¼ 7 2 V3.0817-03 15,9 optical (5) -
HD 319-259 155 D1/2 5EX2 24 G1¼ 7 3 V3.0817-03 15,9 electrical (5) change-over
HD 319-286 195 D1/3 10EX2 24 G1¼ - 6 V3.0817-16
1
16,3 electrical (5) change-over
HD 319-276 250 D1/4 10EX2 33 G1¼ 7 2 V3.0817-06 15,9 optical (5) -
HD 319-256 250 D1/4 10EX2 33 G1¼ 7 3 V3.0817-06 15,9 electrical (5) change-over
HD 319-288 270 D1/5 16EX2 25 G1¼ - 6 V3.0817-18
1
16,3 electrical (5) change-over
HD 319-278 330 D1/6 16EX2 33 G1¼ 7 2 V3.0817-08 15,9 optical (5) -
HD 319-258 330 D1/6 16EX2 33 G1¼ 7 3 V3.0817-08 15,9 electrical (5) change-over
HD 419-289 155 D2/1 5EX2 29 G1¼ - 6 V3.0823-13
1
17,8 electrical (5) change-over
HD 419-279 190 D2/2 5EX2 33 G1¼ 7 2 V3.0823-03 17,2 optical (5) -
HD 419-259 190 D2/2 5EX2 33 G1¼ 7 3 V3.0823-03 17,2 electrical (5) change-over
HD 419-286 265 D2/3 10EX2 33 G1¼ - 6 V3.0823-16
1
17,8 electrical (5) change-over
HD 419-276 330 D2/4 10EX2 47 G1¼ 7 2 V3.0823-06 17,2 optical (5) -
HD 419-256 330 D2/4 10EX2 47 G1¼ 7 3 V3.0823-06 17,2 electrical (5) change-over
HD 419-288 330 D2/5 16EX2 35 G1¼ - 6 V3.0823-18
1
17,8 electrical (5) change-over
HD 419-278 380 D2/6 16EX2 48 G1¼ 7 2 V3.0823-08 17,2 optical (5) -
HD 419-258 380 D2/6 16EX2 48 G1¼ 7 3 V3.0823-08 17,2 electrical (5) change-over
HD 619-289 220 D3/1 5EX2 41 G1½ - 6 V3.0833-13
1
20,6 electrical (5) change-over
HD 619-279 280 D3/2 5EX2 49 G1½ 7 2 V3.0833-03 19,9 optical (5) -
HD 619-259 280 D3/2 5EX2 49 G1½ 7 3 V3.0833-03 19,9 electrical (5) change-over
HD 619-286 330 D3/3 10EX2 49 G1½ - 6 V3.0833-16
1
20,6 electrical (5) change-over
HD 619-276 400 D3/4 10EX2 67 G1½ 7 2 V3.0833-06 19,9 optical (5) -
HD 619-256 400 D3/4 10EX2 67 G1½ 7 3 V3.0833-06 19,9 electrical (5) change-over
HD 619-288 450 D3/5 16EX2 51 G1½ - 6 V3.0833-18
1
20,6 electrical (5) change-over
HD 619-278 450 D3/6 16EX2 68 G1½ 7 2 V3.0833-08 19,9 optical (5) -
HD 619-258 450 D3/6 16EX2 68 G1½ 7 3 V3.0833-08 19,9 electrical (5) change-over
1
Element differential pressure stable up to 160 bar
Subject to change · 40.70-e · 0215
Page 6
www.argo-hytos.com
Dimensions
E
G
B
A
W
1
ØR
D
ØH
S
Q
O
M
N
L
ØC
1
E
G
A
F
ØC
2
D
I
B
ØC
2
ØR
ØH
U
A
P
B
T
V
Q
S
I
Fl
ange
d
connection
V
ersion wit
h
integrate
d
optica
l
clogging indicator
T
hreaded
p
ort
Minimum distance from
ferromagnetic parts: 7 mm
Terminal connection
K
Version with inte
g
rated
ectrica
c
o
in
in
icator
X
F
X
W
Measurements
Symbols
1 2 3 4 5 6 7
Type A/B C
1
C
2
D E F G H I K L M
Ø/depth
N O P Q
opt./electr.
HD 319 see 31 65 255 45 86 145 109 80 32 66,7 M14/22 31,8 18,5 33 75/92
HD 419 Selection 31 65 319 45 86 145 109 80 32 66,7 M14/22 31,8 18,5 33 75/92
HD 619 Chart 31 65 420 45 86 145 109 80 32 66,7 M14/22 31,8 18,5 33 75/92
Type R S
opt./electr
T U V W
Ø/depth
X
HD 319 152 24/30 148 8 80 M12/18 27
HD 419 152 24/30 148 8 80 M12/18 27
HD 619 152 24/30 148 8 80 M12/18 27
Subject to change · 40.70-e · 0215
Page 7
www.argo-hytos.com
Spare Parts
8
7
5
4
1
6
3
2
Pos. Designation Part No.
1 Filter bowl HD 319
(with Pos. 2 und 3)
HD 250.0701
1 Filter bowl HD 419
(with Pos. 2 und 3)
HD 451.0702
1 Filter bowl HD 619
(with Pos. 2 und 3)
HD 619.0701
2 Back-ring HD 255.0102
3 O-ring 94,84 x 3,53 N007.0953
4 Filter element see Chart / col. 9
5 Reed switch with screws and socket
(Pos. 6)
HD 049.1410
6 Reed switch with screws
DIN 43650 - AF3
DG 041.1220
7 Optical indicator
(with Pos. 8)
HD 049.1400
8 O-ring 17 x 2 N007.0172
The functions of the complete filters as well as the outstanding
features of the filter elements assured by ARGO-HYTOS can
only be guaranteed if original ARGO-HYTOS spare parts are
used.
Quality Assurance
Quality management according to DIN EN ISO 9001
To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to
the following ISO standards:
ISO 2941 Verification of collapse/burst pressure rating
ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 2943 Verification of material compatibility with fluids
ISO 3968 Evaluation of pressure drop versus flow characteristics
ISO 16889 Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity)
ISO 23181 Determination of resistance to flow fatigue using high viscosity fluid
Before release into the series production the filter casing is tested for fatigue strength in our pressure pulse test rig.
Various quality controls during the production process guarantee the leakfree function and solidity of our filters.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.