Subject to change · 20.70-e · 0215
Page 1
www.argo-hytos.com
E 303 · E 503 · E 703
Tank top mounting · Connection up to SAE 2½ · Nominal flow rate up to 900 l/min
Return Filters
Description
Application
In the return line circuits of hydraulic systems.
Performance features
Protection against wear:
By means of filter elements that, in full-flow filtration, meet even
the highest demands regarding cleanliness classes.
Protection against malfunction:
By means of full-flow filtration in the system return, the pumps
above all are protected from dirt particles remaining in the
system after assembly, repairs, or which are generated by wear
or enter the system from outside.
Special features
› By-pass valve:
The location close to the inlet port prevents dirt particles
retained by the filter element from entering into the clean oil
side.
› Removable bowl:
In case of maintenance the filter bowl is removed together
with the filter element - therefore dirt particles are not flushed
back into the tank.
Filter elements
Flow direction from outside to centre. The star-shaped pleating
of the filter material results in:
› large filter surfaces
› low pressure drop
› high dirt-holding capacities
› long service life
Filter maintenance
By using a clogging indicator the correct moment for main-
tenance is stated and guarantees the optimum utilization of the
filter life.
Materials
Filter head cover: Steel
Filter head: Aluminium alloy
Filter bowl: Steel
Seals: NBR (FPM on request)
Filter media: EXAPOR
®
MAX 2 - inorganic multi-layer
microfibre web
Return Filters E 503
Page 2
www.argo-hytos.com
Subject to change · 20.70-e · 0215
Accessories
Extension pipes and diffusers on the bowl outlet are available on
request.
Extension pipe:
A correct extension pipe length ensures oil outlet below
minimum oil level and prevents foaming.
Diffuser:
Diffusers reduce oil velocity and direct the oil to 90° outlet flow.
This function prevents also oil foaming and whirling up of solid
particles settled at the tank bottom.
Electrical and optical clogging indicators are available on request.
Dimensions and technical data see catalogue sheet 60.20
Characteristics
Nominal flow
Up to 900 l/min (see Selection Chart, column 2)
The nominal flow rates indicated by ARGO-HYTOS are based on
the following features:
› closed by-pass valve at ν ≤ 200 mm
2
/s
› element service life > 1000 operating hours at an average
fluid contamination of 0,07 g per l/min flow volume
› flow velocity in the connection lines ≤ 4,5 m/s
Connection
SAE-flange (3.000 psi). Sizes see Selection Chart, column 6
(other port threads on request)
Filter fineness
5 µm(c) ... 16 µm(c)
β-values according to ISO 16889
(see Selection Chart, column 4 and diagram Dx)
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Chart, column 5)
Hydraulic fluids
Mineral oil and biodegradable fluids
(HEES and HETG, see info-sheet 00.20).
Temperature range
-30 °C ... +100 °C (temporary -40 °C ... +120 °C)
Viscosity at nominal flow rate
› at operating temperature: ν < 60 mm
2
/s
› as starting viscosity: ν
max
= 1200 mm
2
/s
› at initial operation:
The recommended starting viscosity can be read from the
diagram D (pressure drop as a function of the kinematic
viscosity) as follows: Find the 70 % ∆p of the cracking
pressure of the by-pass valve on the vertical axis. Draw a
horizontal line so that it intersects the ∆p curve at a point.
Read this point on the horizontal axis for the viscosity.
Operating pressure
Max. 10 bar
Mounting position
Preferably vertical, outlet downwards
Page 3
www.argo-hytos.com
Subject to change · 20.70-e · 0215
Diagrams
∆p-curves for complete filters in Selection Chart, column 3
D1
Pressure drop as a function of the
flow volume at ν = 35 mm
2
/s (0 = casing empty)
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
0,1
0,2
0,3
0,4
0,5
0,6
1
2
3
0
200 400 600 800 1000
E 303
∆p [bar]
Q [l/min]
0
1
0,5
1,5
2,5
3,5
2
3
4
2
3
1
200 400 600
800
1000
∆p [bar]
ν [mm
2
/s]
D2
Pressure drop as a function of the
flow volume at ν = 35 mm
2
/s (0 = casing empty)
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
1
0,5
1,5
2,5
3,5
2
3
4
2
3
1
200 400 600
800
1000
∆p [bar]
0
0,1
0,2
0,3
0,4
0,5
0,6
1
2
3
0
200 400 600 800 1000
E 503
∆p [bar]
Q [l/min]
ν [mm
2
/s]
D3
Pressure drop as a function of the
flow volume at ν = 35 mm
2
/s (0 = casing empty)
0
0,1
0,2
0,3
0,4
0,5
0,6
1
2
3
0
200 400 600 800 1000
E 703
∆p [bar]
Q [l/min]
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
1
0,5
1,5
2,5
3,5
2
3
4
2
3
1
200 400 600
800
1000
∆p [bar]
ν [mm
2
/s]
Page 4
www.argo-hytos.com
Subject to change · 20.70-e · 0215
Filter fineness curves in Selection Chart, column 4
Filtration ratio β as a function of particle size x obtained by
the Multi-Pass-Test according to ISO 16889
The abbreviations represent the following β-values resp.
finenesses:
For EXAPOR
®
MAX 2 and Paper elements:
5EX2 = β
5 (c)
= 200 EXAPOR
®
MAX 2
7EX2 = β
7 (c)
= 200 EXAPOR
®
MAX 2
10EX2 = β
10 (c)
= 200 EXAPOR
®
MAX 2
16EX2 = β
16 (c)
= 200 EXAPOR
®
MAX 2
30P = β
30 (c)
= 200 Paper
Based on the structure of the filter media of the 30P paper
elements, deviations from the printed curves are quite probable.
For screen elements:
40S = screen material with mesh size 40 µm
60S = screen material with mesh size 60 µm
100S = screen material with mesh size 100 µm
Tolerances for mesh size according to DIN 4189.
For special applications, finenesses differing from these curves
are also available by using special composed filter media.
Dx
Filtration ratio β for particles > x µm
Particle size x [µm] (for particles larger
than the given particle size x)
Efficiency [%]
Page 5
www.argo-hytos.com
Subject to change · 20.70-e · 0215
Selection Chart
All filters are delivered with a plugged clogging indicator connection M12 x 1,5. (Mounting holes for differential pressure switches
on request). As clogging indicators either manometers or electrical pressure switches can be used. Two different head pieces with
three various connecting options are available. All filters can also be supplied with an outlet diffuser. Optional extension pipes adapt
the filter length to various tank depths. For ordering of accessories please use the below mentioned codes.
Order example: The filter E 703-256 has to be supplied with 2 connections (A and A4) and an extension pipe
for 800 mm length.
Order description: E 703- 256 / RV / EV 800
Connections:
two various options are available
two connections
1
(A und A4)
2
- SAE2½ und G1
four connections
1
(A1, A2, A3 und A4) - 2 x G1¼ / SAE1½, G¾ und G1
Bowl outlet
2
:
two various options are available
VD - Outlet diffuser, RV - extension pipe
Extension pipe
3
:
four various lengths are available
EV = K + 64 / + 164 / + 264 / + 454 mm (see section dimensions and measurements)
For the appropriate clogging indicators see catalogue sheet 60.20.
Remarks:
› The switching pressure of the electrical pressure switch has always to be lower than the cracking pressure of the by-pass valve
(see Selection Chart, column 7).
›Clogging indicators are optional and always delivered detached from the filter.
›The filters listed in this chart are standard filters. Other designs available on request.
1
The individual flow rates must be matched to the connections
2
Connection G1 (A4) with locking screw
3
On request an outlet diffuser can be combined with an extension pipe
2
4
l/min g bar kg
1 2 3 4 5 6 7 8 9 10 11
E 303-453 220 D1/1 5EX2 91 2 x G1¼ / SAE1½, G¾ + G1 2,5 2 V2.1425-23 8,9 -
E 303-456 350 D1/2 10EX2 120 2 x G1¼ / SAE1½, G¾ + G1 2,5 2 V2.1425-26 8,9 -
E 303-458 500 D1/3 16EX2 130 2 x G1¼ / SAE1½, G¾ + G1 2,5 2 V2.1425-28 8,9 -
E 503-453 350 D2/1 5EX2 150 2 x G1¼ / SAE1½, G¾ + G1 2,5 2 V2.1440-23 11,7 -
E 503-456 540 D2/2 10EX2 200 2 x G1¼ / SAE1½, G¾ + G1 2,5 2 V2.1440-26 11,7 -
E 503-458 750 D2/3 16EX2 200 2 x G1¼ / SAE1½, G¾ + G1 2,5 2 V2.1440-28 11,7 -
E 703-453 500 D3/1 5EX2 230 2 x G1¼ / SAE1½, G¾ + G1 2,5 2 V2.1460-23 15,4 -
E 703-456 740 D3/2 10EX2 300 2 x G1¼ / SAE1½, G¾ + G1 2,5 2 V2.1460-26 15,4 -
E 703-458 900 D3/3 16EX2 310 2 x G1¼ / SAE1½, G¾ + G1 2,5 2 V2.1460-28 15,4 -
Part No.
Nominal flow rate
1
Pressure drop
diagram
D
/curve no.
Filter fineness see Diagr.
Dx
Dirt-holding capacity
Connection A
SAE (3000 psi)
Cracking Pressure of by-pass
Symbol
Replacement filter element
Part no.
Weight
Remarks
Page 6
www.argo-hytos.com
Subject to change · 20.70-e · 0215
Dimensions
B
P
Z
F
Ø E
Ø C
Ø D
B
I+(EV-K)
H
G
A
R
K
EV
F
O
Ø E
Ø C
Ø D
Ø X
T
U
2xM
C
L
O
A4
(with locking screw)
N
Q
S
M
L
P1
W
W
W
M
A
1
P
1
A
2
L
A
4
A
3
V
17
Tank surface sealing with
O-ring N007.1806
(included in basic equipment)
P
1
Connection M12 x 1,5
for clogging indicator
standard
(mounting holes for
differential pressure
switches on request)
90º
B
Option RV EV
19
Version with 4 connections Version with 2 connections
Option VD
Required mounting surface
Dia hole
in reservoir
When using SAE-flanges
consider sizes G or Z
Measurements
Type A B C D E F G H I K L M N O P Q R S T U V W X Z
E 303 see 182 180 152 179 12 55 133 400 276 220 104 125 11,5* 113 20 M12 115 58 79 70 106 100 41,5
E 503 Selec- 182 180 152 179 12 55 133 550 430 220 104 125 11,5* 113 20 M12 115 58 79 70 106 100 41,5
E 703 tion Chart 182 180 152 179 12 55 133 810 636 220 104 125 11,5* 113 20 M12 115 58 79 70 106 100 41,5
* for M10
Symbols
12
1 2 3 4
Page 7
www.argo-hytos.com
Subject to change · 20.70-e · 0215
Spare Parts
3
7
8
1
2
4
5
6
6
Pos. Designation Part No.
1 Cover assy (2 connections) E 303.1200
1 Cover assy (4 connections) E 703.2202
2 By-pass (2,5 bar) E 703.1510
3 Filter elements see Chart. / col. 9
4 Filter bowl E 303* E 303.1900
4 Filter bowl E 503* E 503.1910
4 Filter bowl E 703* E 703.1900
5 O-ring 145,42 x 5,33 N007.1455
6 O-ring 180 x 6 N007.1806
7 Clip (only option VD) N026.0311
8 Diffuser (only option VD) E 703.0701
* Please indicate options (VD, VDEV and RVEV respectively)
The functions of the complete filters as well as the outstanding
features of the filter elements assured by ARGO-HYTOS can only
be guaranteed if original ARGO-HYTOS spare parts are used.
Quality Assurance
Quality management according to DIN EN ISO 9001
To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to
the following ISO standards:
ISO 2941 Verification of collapse/burst pressure rating
ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 2943 Verification of material compatibility with fluids
ISO 3968 Evaluation of pressure drop versus flow characteristics
ISO 16889 Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity)
ISO 23181 Determination of resistance to flow fatigue using high viscosity fluid
Various quality controls during the production process guarantee the leakfree function and solidity of our filters.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.