Subject to change · 20.85-e · 0714
Page 1
www.argo-hytos.com
E 084
Tank top mounting · Connection up to G1 · Nominal flow rate up to 80 l/min
Return-Suction Filters
Description
Application
For operation in units with hydrostatic drives, when the return
flow is under all operating conditions higher than the oil flow of
the feed pump.
Performance features
Protection against wear:
By means of filter elements that, in full-flow filtration, meet even
the highest demands regarding cleanliness classes.
Suction filter function:
Because of the 100%-filtration of the suction flow, no dirt can
get into the feed pump.
Return filter function:
By means of full-flow filtration in the system return, the pumps
above all are protected from dirt particles remaining in the
system after assembly, repairs, or which are generated by wear
or enter the system from outside.
Return-Suction-Filter E 084
Page 2
www.argo-hytos.com
Subject to change · 20.85-e · 0215
Function (schematic):
A
B
1
2
3
Functional characteristics
The hydraulic oil returning from the circuit (A) passes the filter
element (1), is pressurized by a 0,5 bar check valve (2) and
supplied to the feed pump (B). The surplus oil flows filtered over
the integral check valve into the reservoir.
As the feed pump is always fed with pressurized oil, the risk of
cavitation is minimized and full performance is available even
during the critical cold start phase.
An integral pressure relief valve (3) prevents too high back
pressure and protects the shaft seals against damages. As this
valve leads the oil directly into the tank there is no direct
connection between the return line (A) and the connection of
the feed pump (B) (no bypass valve function).
The emergency-suction valve (4) with 125 µm protection strainer
(5) supplies the feed pump in case of a short term of lack of oil.
During normal operation, a lack of oil may definitely not occur
(refer to „Design“ section).
Start up / Deaeration
For units with emergency-suction valve and protection strainer
the start up set E 084.1710 can be used to de-aerate the
hydraulic system at first start up or at start up after repair;
hereby the immediate supply of the feed pump with hydraulic oil
is guaranteed.
For all other types, deaerating instructions published by the
manufacturers of hydraulic drives must be observed.
Filter maintenance
By using a clogging indicator the correct moment for main-
tenance is indicated and guarantees therefore the optimum
utilization of the filter elements.
Filter elements
Flow direction from centre to the outside. The star-shaped
pleating of the filter material results in:
› large filter surfaces
› low pressure drop
› high dirt-holding capacities
› long service life
Dirt deposits are entirely removed when the element is changed
and cannot re-enter the tank.
Accessories
Electrical and optical clogging indicators are available.
Dimensions and technical data see catalogue sheet 60.20.
4
3
5
B
A
Emergency-suction (schematic)
Page 3
www.argo-hytos.com
Subject to change · 20.85-e· 0215
Layout
General
In machines with a hydrostatic drive and combined working
hydraulic system, return-suction filters replace the suction or
pressure filters previously required for the feed pump of the
closed-loop hydrostatic drive circuit as well as the return filter for
the open-loop working hydraulic circuit.
While each circuit operates independently with separate filters,
the combination of the two circuits via the return-suction filter
causes interaction between the circuits.
If the design criteria described below are taken into account, you
can take full advantage of the benefits provided by the re-
turn-suction filter concept, thus making sure that your system
performs reliably even under extreme operating conditions.
Required return flow in the system
In order to maintain a precharging pressure of approx. 0,5 bar at
the intake of the feed pump, the return flow must exceed the
suction flow under any operating condition:
Special feature:
› Versions with hole (Ø 4 mm) in the pressurizing valve:
at least 10 l/min of excess flow
Permitted feed pump flow rate
› at operating temperature (ν < 60 mm
2
/s, rpm=max):
feed pump flow rate < 0,5 x rated return flow according to
column 2 of selection table
› at cold start-up (ν < 1000 mm
2
/s, rpm = 1000 min
-1
):
feed pump flow rate < 0,2 x rated return flow according to
column of selection table
Please contact us if your system operates with higher flow rates
than stated above.
Flow velocity in the connecting lines
› Flow velocity in the return lines ≤ 4,5 m/s
› Flow velocity in the suction lines ≤ 1,5 m/s
Permitted pressure in the suction lines
At cold start up (ν < 1000 mm
2
/s, rpm = 1.000 min
-1
):
feed pump flow rate ≤ 0,2 x rated return flow. The pressure loss
in the suction lines must not exceed 0,4 bar.
Backpressures in system return lines
If drain oil from the hydrostatic drive is routed across the filter in
addition to the flow of the open-loop circuit, the following has
to be observed in order to protect the shaft seals:
› permitted leakage oil pressure for a given viscosity and speed
(manufacturer’s specifications!)
› pressure loss caused by the leakage oil pipes
› pressure loss caused by the oil cooler used
› backpressure of the filter for a given flow rate or kinematic
viscosity (refer to pressure loss diagrams)
Depending on the application, the use of a cooler bypass valve is
recommended.
Generously sized drain oil pipes are also of advantage.
Filter fineness grades
With the filter fineness grades available, the following oil
cleanliness according to ISO 4406 can be achieved:
› 10EX2: 18/15/11 ... 14/11/7
› 16EX2: 20/17/12 ... 17/14/10
Even with the 16EX2 fineness grade, the requirements specified
by manufacturers of hydrostatic drives are sometimes exceeded
significantly.
If components requiring a still better oil purity are used, we
recommend the 10EX2 filter fineness grade.
Suggested circuit layouts
A) The leakage oil of the hydrostatic drive is routed across the
filter.
Working hydraulics
Drain oil
to filter
The entire dirt produced in the hydrostatic drive by abrasion is
filtered out immediately and is thus not taken in by the pump of
the open-loop circuit.
This circuit layout is always recommended if the return flow only
slightly exceeds the suction flow, i.e. if there is a risk that the 0,5
bar precharging pressure cannot be maintained.
B) The drain oil of the hydrostatic drive is not routed across the
filter but is discharged directly into the tank.
Working hydraulics
Drain oil
to tank
This circuit layout has the advantage that drain oil pressures are
comparatively low.
A
P
B
A
P
B
Page 4
www.argo-hytos.com
Subject to change · 20.85-e · 0215
Characteristics
Nominal flow rate
Up to 80 l/min in return line (see Selection Chart, column 2)
Up to 40 l/min feed pump flow rate (see Layout)
The nominal flow rates indicated by ARGO-HYTOS are based on
the following features:
› closed by-pass valve at ν ≤ 200 mm
2
/s
› element service life > 1000 operating hours at an average fluid
contamination of 0,07 g per l/min flow volume
› flow velocity in the return lines ≤ 4,5 m/s
› flow velocity in the suction lines ≤ 1,5 m/s
Connection
Threaded ports according to ISO 228 or DIN 13.
Sizes see Selection Chart, column 6 and 7
(other port threads on request)
Filter fineness
10 µm(c) ... 16 µm(c)
b-Werte nach ISO 16889
(see Selection Chart, column 4 and diagram Dx)
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Chart, column 5)
Hydraulic fluids
Mineral oil and biodegradable fluids
(HEES and HETG, see info-service 00.20).
Temperature range
-30 °C ... +100 °C (temporary -40 °C ... +120 °C)
Viscosity at nominal flow rate
› at operating temperature: ν < 60 mm
2
/s
› as starting viscosity: ν
max
= 1000 mm
2
/s
› at initial operation:
The recommended starting viscosity can be read from the
diagram D (pressure drop as a function of the kinematic
viscosity) as follows: Find the 70 % ∆p of the cracking
pressure of the by-pass valve on the vertical axis. Draw a
horizontal line so that it intersects the ∆p curve at a point.
Read this point on the horizontal axis for the viscosity.
Operating pressure
Max. 10 bar
Materials
Screw-on cap: Polyamide, GF-reinforced
Filter head: Aluminium alloy
Filter bowl: Aluminium alloy
Seals: NBR (FPM on request)
Filter media: EXAPOR
®
MAX 2 - inorganic multi-layer
microfibre web
Fitting position
› Standard type no restriction, preferably vertical
› Models with emergency-suction valve can vary up to 15° from
the vertical
› Models with hole ∅ 4 mm in the check valve can vary up to
45° from the vertical
Even under unfavourable operating conditions (min. oil level,
max. sloping) the oil outlet resp. emergency suction has to be
below the oil level.
Special designs are available for horizontal assembly.
Page 5
www.argo-hytos.com
Subject to change · 20.85-e· 0215
Diagrams
∆p-curves for complete filters in Selection Chart, column 3
(50 % of the nominal flow volume via connection B)
D1
Pressure drop as a function of the flow volume
at ν = 35 mm
2
/s (00/01 = casing empty without/with
hole Ø 4 mm)
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
1,0
0,5
1,5
2,0
E 084
1
2
0
01
20 40 60 80 100 120
0
1
2
3
4
5
2
1
200 400 600
800
1000
∆p [bar]
Q [l/min]
∆p [bar]
ν [mm
2
/s]
Filter fineness curves in Selection Chart, column 4
Dx
Filtration ratio β as a function of particle size x obtained
by the Multi-Pass-Test according to ISO 16889
The abbreviations represent the following ß-values resp.
finenesses:
For EXAPOR
®
MAX 2 and Paper elements:
5EX2 = β
5 (c)
= 200 EXAPOR
®
MAX 2
7EX2 = β
7 (c)
= 200 EXAPOR
®
MAX 2
10EX2 = β
10 (c)
= 200 EXAPOR
®
MAX 2
16EX2 = β
16 (c)
= 200 EXAPOR
®
MAX 2
30P = β
30 (c)
= 200 Paper
Based on the structure of the filter media of the 30P paper
elements, deviations from the printed curves are quite probable.
For special applications, finenesses differing from these curves
are also available by using special composed filter material.
Filtration ratio β for particles > x µm
Particle size x [µm] (for particles larger
than the given particle size x)
Efficiency [%]
Page 6
www.argo-hytos.com
Subject to change · 20.85-e · 0215
Selection Chart
All filters are delivered with a plugged clogging indicator connection M12 x 1,5 (connection P
1
).
As clogging indicators either manometers or electrical pressure switches can be used.
For the appropriate clogging indicators see catalogue sheet 60.20.
Remarks:
› The start of the red area respectively the switching pressure of the electrical pressure switch has always to be lower than the
cracking pressure of the pressure relief valve (see Selection Chart, column 9).
› Clogging indicators are optional and always delivered detached from the filter.
› The filters listed in this chart are standard filters. If modifications are required, e.g. for horizontal assembly or with integrated
suction valve integrated into the pressure relief valve (see section symbols, symbol no. 5) to guarantee the emergency steering
feature for vehicles with official road use, we kindly ask for your request.
› For deaeration a bleed screw (for connection P
1
) with Part No. SV 0112.15 is available.
l/min g bar bar kg
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E 084-56 75 D1/1 10EX2 32 G1 G¾ 0,5 3,0 2 V3.0724-06 1,7
3
E 084-77 80 D1/2 16EX2 31 G1 G¾ 0,5 2,5 2 V3.0724-08 1,7
3
E 084-88 80 D1/2 16EX2 31 G¾ G¾ 0,5 2,5 2 V3.0724-08 1,7
3
E 084-78 80 D1/2 16EX2 31 G1 G¾ 0,5 2,5 1 V3.0724-08 1,7 -
E 084-87 80 D1/2 16EX2 31 G¾ G¾ 0,5 2,5 1 V3.0724-08 1,7 -
E 084-277 80 D1/2 16EX2 31 G1 G¾ 0,5 2,5 4 • V3.0724-08 1,8
4
E 084-288 80 D1/2 16EX2 31 G¾ G¾ 0,5 2,5 4 • V3.0724-08 1,8
4
E 084-287 80 D1/2 16EX2 31 G1 G¾ 0,5 2,5 3 • V3.0724-08 1,8
4+5
1
Cracking pressure of check valve
2
Cracking pressure of pressure relief valve
3
With hole Ø 4 mm in the check valve for oil drain when opening the filter cover
4
With emergency-suction valve and protection strainer (mesh size 125 µm)
5
Suitable for horizontal assembly
Part No.
Nominal return flow rate
Pressure drop see
diagram
D/
curve no.
Filter fineness see Diagr.
Dx
Dirt-holding capacity
Connection A
Connection B
Cracking pressure of CV
1
Cracking pressure of PRV
2
Symbol
Suction valve
Replacement filter element
Part No.
Weight
Remarks
Page 7
www.argo-hytos.com
Subject to change · 20.85-e· 0215
Dimensions
Q
1
Q
2
O
P
P
1
B
A
N
Ø M
J
2
J
1
A
F
G
I
H
E
C
Ø L
K
1
Y*
Ø D
K
2
Y*
R
T
Z
V
U
W
X
S
M10
M6
M10
B
min. oil level
Connection M12 x 1,5
for clogging indicator
a
nd protection straine
r
P
ort sizes and mounting
f
ace
Measurements
Type A B C D E F G H I J
1
J
2
K
1
K
2
L M N O P Q
1
Q
2
E 084 G¾,G1 G¾ 48 73,5 12 47 21 102 315 AF 41 AF 32 254 268 20,5 104,5 90 60 69 11 6,6
Type R S T U V W X Y* Z
E 084 115 25 65 100 79 21 38 224 55
Symbols
1 2 3 4 5
* Oil outlet resp. emergency suction has to be under all operating cond. below min. oil level (given by Y)
Page 8
www.argo-hytos.com
Subject to change · 20.85-e · 0215
Spare Parts
4
1
2
3
5
6
Pos. Designation Part No.
1 Screw-on cap E 103.0201
2 Flat gasket N031.0841
3 O-ring 72 x 3 N007.0723
4 Filter element see Chart. / col. 11
5 O-ring 84 x 4 N007.0844
6 O-ring 23 x 4 N007.0231
The functions of the complete filters as well as the outstanding
features of the filter elements assured by ARGO-HYTOS can only
be guaranteed if original ARGO-HYTOS spare parts are used.
Quality Assurance
Quality management according to DIN EN ISO 9001
To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to
the following ISO standards:
ISO 2941 Verification of collapse/burst pressure rating
ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 2943 Verification of material compatibility with fluids
ISO 3968 Evaluation of pressure drop versus flow characteristics
ISO 16889 Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity)
ISO 23181 Determination of resistance to flow fatigue using high viscosity fluid
Various quality controls during the production process guarantee the leakfree function and solidity of our filters.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.