Page 265
www.argo-hytos.com
D 042 · D 062
In-line mounting · Operating pressure up to 100 bar / 1450 psi · Nominal fl ow rate up to 90 l/min / 23.8 gpm
Pressure Filters
Description
Application
In the pressure circuits of hydraulic and lubrication systems.
Performance features
Protection against wear:
By means of fi lter elements that even in full-fl ow fi ltration meet
the highest demands regarding cleanliness classes.
Protection against malfunction:
Through installation near to the control valves or other expensive
components. The specifi c determined fl ow rate guarantees a
closed by-pass valve even at ν ≤ 200 mm
2
/s / 927 SUS (cold start
condition).
Filter elements
Flow direction from outside to center.
The star-shaped pleating of the fi lter material results in:
› large fi lter surfaces
› low pressure drop
› high dirt-holding capacities
› long service life
Filter maintenance
By using a clogging indicator the correct moment for main-
tenance is stated and guarantees the optimum utilization of the
fi lter life.
Materials
Filter head: Aluminum alloy
Filter bowl: Aluminum alloy
Seals: NBR (FPM on request)
Filter media: EXAPOR
®
MAX 2 - inorganic multi-layer
microfi ber web
Paper - cellulose web, impregnated with resin
Clogging indicators
Electrical and / or optical clogging indicators can be integrated in
the fi lter head if desired. For dimensions and technical data see
catalog sheet 60.40.
Suitable retrofi ttable indicators - optionally with one or two
switching points or temperature compensation - can be found in
catalog sheet 60.30.
Subject to change · 30.10-EN/US · 0818
Pressure Filter D 042
Page 266
www.argo-hytos.com
Characteristics
Operating pressure
0 ... 63 bar / 914 psi, min. 3 x 10
6
pressure cycles
Nominal pressure according to DIN 24550
0 ... 100 bar / 1450 psi, min. 10
4
pressure cycles
Quasi-static operating pressure
Permissible pressures for other numbers of cycles
Nominal flow rate
Up to 90 l/min / 23.7 gpm (see Selection Chart, column 2)
The nominal flow rates indicated by ARGO-HYTOS are based on
the following features:
› closed by-pass valve at ν ≤ 200 mm
2
/s / 927 SUS
› element service life > 1000 operating hours at an average
fluid
› contamination of 0.07 g per l/min / 0.27 g per gpm
flow volume
› flow velocity in the connection lines:
up to 100 bar ≤ 6 m/s / 1450 psi ≤ 19.7 ft/s
Filter fineness
5 µm(c) ... 30 µm(c)
β-values according to ISO 16889
(see Selection Chart, column 4 and diagram Dx).
Dirt-holding capacity
Values in g test dust ISO MTD according to ISO 16889
(see Selection Chart, column 5).
Hydraulic fluids
Mineral oil and biodegradable fluids
(HEES and HETG, see info-sheet 00.20).
Temperature range
-30 °C ... +100 °C (temporary -40 °C ... +120 °C)
-22 °F ... +212 °F (temporary -40 °F ... +248 °F)
Viscosity at nominal flow rate
› at operating temperature: ν < 60 mm
2
/s / 280 SUS
› as starting viscosity: ν
max
= 1200 mm
2
/s / 5560 SUS
› at initial operation:
The recommended starting viscosity can be read from the
diagram D (pressure drop as a function of the kinematic
viscosity) as follows: Find the 70% ∆p of the cracking pressure
of the by-pass valve on the vertical axis. Draw a horizontal line
so that it intersects the ∆p curve at a point. Read this point on
the horizontal axis for the viscosity.
Mounting position
Preferably vertical, filter head on top.
Connection
Threaded ports according to
› ISO 228 or DIN 13
› SAE standard J514
Sizes see Selection Chart, column 6
(other port threads on request).
100
75
50
0
0
10
3
10
4
10
5
10
6
10
7
10
8
(1450)
(1088)
(725)
Operating pressure p [bar] [psi]
Number of cycles n
Subject to change · 30.10-EN/US · 0818
Page 267
www.argo-hytos.com
Diagrams
∆p-curves for complete filters in Selection Chart, column 3
Dx
Filter fineness curves in Selection Chart, column 4
Filtration ratio β as a function of particle size x obtained
by the Multi-Pass-Test according to ISO 16889
The abbreviations represent the following β-values resp.
finenesses:
For EXAPOR
®
MAX2 and Paper elements:
5EX2 = β
5 (c)
= 200 EXAPOR
®
MAX 2
7EX2 = β
7 (c)
= 200 EXAPOR
®
MAX 2
10EX2 = β
10 (c)
= 200 EXAPOR
®
MAX 2
16EX2 = β
16 (c)
= 200 EXAPOR
®
MAX 2
30P = β
30 (c)
= 200 Paper
Based on the structure of the filter media of the 30P paper
elements, deviations from the printed curves are quite probable.
For special applications, finenesses differing from these curves
are also available by using special composed filter media.
Filtration ratio β for particles > x µm
Particle size x [µm] (for particles larger
than the given particle size x)
Efficiency [%]
D2
Pressure drop as a function of the flow volume
at ν = 35 mm
2
/s / 162 SUS (0 = casing empty)
Pressure drop as a function of the
kinematic viscosity at nominal flow
D1
Pressure drop as a function of the flow volume
at ν = 35 mm
2
/s / 162 SUS (0 = casing empty)
Pressure drop as a function of the
kinematic viscosity at nominal flow
0
0,5
1,0
1,5
2,0
D 042
1+5
2+6
4
0
3
10 20 30 40 50
0
2
8
10
4
6
1
1
4
4
5
6
5+6
3
2
2
200 400 600
800
1000
0
0,5
1,0
1,5
2,0
D 062
1+5
2+6
4
0
3
20 40 60 80
100
0
2
8
10
4
6
1
4
5
6
4
2
3
200 400 600
800
1000
ν [mm
2
/s]
ν [SUS]
Q [l/min]
∆p [bar]
∆p [psi]
∆p [bar]
∆p [psi]
Q [gpm]
ν [mm
2
/s]
ν [SUS]
Q [l/min]
∆p [bar]
∆p [psi]
∆p [bar]
∆p [psi]
Q [gpm]
Subject to change · 30.10-EN/US · 0818
0 927 1854 2781 3708 4635
29.0
21.8
14.5
7.3
0 2.6 5.3 7.9 10.6 13.2
145
116
87
58
29
0 927 1854 2781 3708 4635
29.0
21.8
14.5
7.3
0 5.3 10.6 15.8 21.1 26.4
145
116
87
58
29
2.0
1.5
1.0
0.5
2.0
1.5
1.0
0.5
Page 268
www.argo-hytos.com
Selection Chart
1
Preferred type, no minimum order quantity required
2
Paper media supported with metal gauze
l/min g bar kg
1 2 3 4 5 6 7 8 9 10 11 12
D 042-153 16 D1/1 5EX2 4.9 G½ 3.5 1 V3.0510-03 0.8 retrofittable -
D 042-156
1
27 D1/2 10EX2 6.8 G½ 3.5 1 V3.0510-06 0.8 retrofittable -
D 042-158
1
44 D1/3 16EX2 6.9 G½ 3.5 1 V3.0510-08 0.8 retrofittable -
D 042-151 40 D1/4 30P 3.6 G½ 3.5 1 P3.0510-11
2
0.8 retrofittable -
D 042-183 30 D1/5 5EX2 4.9 G½ 7 1 V3.0510-03 0.8 retrofittable -
D 042-186 44 D1/6 10EX2 6.8 G½ 7 1 V3.0510-06 0.8 retrofittable -
D 062-153 32 D2/1 5EX2 10 G½ 3.5 1 V3.0520-03 1.1 retrofittable -
D 062-156
1
57 D2/2 10EX2 14 G¾ 3.5 1 V3.0520-06 1.1 retrofittable -
D 062-158
1
90 D2/3 16EX2 15 G¾ 3.5 1 V3.0520-08 1.1 retrofittable -
D 062-15
1
80 D2/4 30P 7.1 G¾ 3.5 1 P3.0520-01
2
1.1 retrofittable -
D 062-183 48 D2/5 5EX2 10 G½ 7 1 V3.0520-03 1.1 retrofittable -
D 062-196 80 D2/6 10EX2 14 G¾ 7 1 V3.0520-06 1.1 retrofittable -
Part No.
Nominal flow rate
Pressure drop see
diagram D/curve no.
Filter fineness see diagr. Dx
Dirt-holding capacity
Connection A/B
Cracking pressure of by-pass
Symbol
Replacement filter element
Part No.
Weight
Clogging indicator
Remarks
Subject to change · 30.10-EN/US · 0818
Optical or electrical clogging indicators are available to monitor the clogging condition of the element. When ordering filters with
integrated monitoring, the abbreviation of the clogging indicator has to be added to the order code of the desired filter variant.
For the appropriate clogging indicator see catalog sheet 60.40.
Oder example: The filter D 042-153 is to be supplied with an optical indicator with automatic reset.
Order code: D 042-153 OD1
Part No. (basic unit)
Clogging indicator
From catalog sheet 60.30, you can see clogging indicators that can be retrofitted.
Remarks:
› The switching pressure of the clogging indicator has always to be lower than the cracking pressure of the by-pass valve
(see Selection Chart, column 7).
› The filters listed in this chart are standard filters. Other designs available on request.
› For versions with electrical clogging indicator, the device socket is not included in the scope of delivery.
› For the electrical clogging indicator of type DIN EN 175301-803 (ED8 and ED9), a device socket with two LEDs is available, which
additionally enables visual indication of the filter contamination (order no. DG 041.1200).
Page 269
www.argo-hytos.com
Selection Chart
1
Preferred type, no minimum order quantity required
2
Corresponds to ¾-16 UNF-2B
3
Corresponds to 1
1
/
16
-12 UN-2B
4
Paper media supported with metal gauze
gpm g SAE psi lbs
1 2 3 4 5 6 7 8 9 10 11 12
D 042-753 4.2 D1/1 5EX2 4.9 -8
2
51 1 V3.0510-03 1.8 retrofittable -
D 042-756
1
7.1 D1/2 10EX2 6.8 -8
2
51 1 V3.0510-06 1.8 retrofittable -
D 042-758
1
11.6 D1/3 16EX2 6.9 -8
2
51 1 V3.0510-08 1.8 retrofittable -
D 042-751 10.6 D1/4 30P 3.6 -8
2
51 1 P3.0510-11
4
1.8 retrofittable -
D 042-783 7.9 D1/5 5EX2 4.9 -8
2
102 1 V3.0510-03 1.8 retrofittable -
D 042-786 11.6 D1/6 10EX2 6.8 -8
2
102 1 V3.0510-06 1.8 retrofittable -
D 062-753 8.5 D2/1 5EX2 10 -8
2
51 1 V3.0520-03 2.4 retrofittable -
D 062-756
1
15.1 D2/2 10EX2 14 -12
3
51 1 V3.0520-06 2.4 retrofittable -
D 062-758
1
23.8 D2/3 16EX2 15 -12
3
51 1 V3.0520-08 2.4 retrofittable -
D 062-751 21.1 D2/4 30P 7.1 -12
3
51 1 P3.0520-01
4
2.4 retrofittable -
D 062-783 12.7 D2/5 5EX2 10 -8
2
102 1 V3.0520-03 2.4 retrofittable -
D 062-786 21.1 D2/6 10EX2 14 -12
3
102 1 V3.0520-06 2.4 retrofittable -
Part No.
Nominal flow rate
Pressure drop see
diagram D/curve no.
Filter fineness see diagr. Dx
Dirt-holding capacity
Connection A/B
Cracking pressure of by-pass
Symbol
Replacement filter element
Part No.
Weight
Clogging indicator
Remarks
Subject to change · 30.10-EN/US · 0818
Optical or electrical clogging indicators are available to monitor the clogging condition of the element. When ordering filters with
integrated monitoring, the abbreviation of the clogging indicator has to be added to the order code of the desired filter variant.
For the appropriate clogging indicator see catalog sheet 60.40.
Oder example: The filter D 042-753 is to be supplied with an optical indicator with automatic reset.
Order code: D 042-753 OD1
Part No. (basic unit)
Clogging indicator
From catalog sheet 60.30, you can see clogging indicators that can be retrofitted.
Remarks:
› The switching pressure of the clogging indicator has always to be lower than the cracking pressure of the by-pass valve
(see Selection Chart, column 7).
› The filters listed in this chart are standard filters. Other designs available on request.
› For versions with electrical clogging indicator, the device socket is not included in the scope of delivery.
› For the electrical clogging indicator of type DIN EN 175301-803 (ED8 and ED9), a device socket with two LEDs is available,
which additionally enables visual indication of the filter contamination (order no. DG 041.1200).
Page 270
www.argo-hytos.com
Dimensions
Measurements in mm
Measurements in inch
Clogging indicator optional:
Pressure holes plugged with screws M4
Subject to change · 30.10-EN/US · 0818
Type A/B C D E F G H I K L M
Ø/depth
N O P Q R S T U V W
D 042 G½ 39 153 27 50 80 58.5 55 27 35 M6 / 8 44 AF 36 19 15 AF 24 60
30
79 70 23
D 062 G½, G¾ 39 249 27 50 80 58.5 55 27 35 M6 / 8 44 AF 36 19 15 AF 24 60
30
79 70 23
Minimum distance from
ferromagnetic parts:
7 mm / 0.3 inch
1
23
Terminal connection ED8
Version with integrated
optical clogging indicator (OD2)
Version with integrated
electrical clogging indicator (ED8) and device socket*
* not included in scope of delivery
Type A/B
SAE
C D E F G H I K L M
Ø/depth
N O
mm
P R
mm
S
D 042 -8 1.54 6.02 1.06 1.97 3.15 2.30 2.17 1.06 1.38 M6 / 0.32 1.73 AF 36 0.75 AF 24 2.36
D 062 -8 / -12 1.54 9.80 1.06 1.97 3.15 2.30 2.17 1.06 1.38 M6 / 0.32 1.73 AF 36 0.75 AF 24 2.36
Type T U V W
D 042
1.18
3.11 7.76 0.91
D 062
1.18
3.11 7.76 0.91
Page 271
www.argo-hytos.com
Spare Parts
Pos. Designation Part No.
1 Filter bowl D 042 D 044.0101
1 Filter bowl D 062 D 064.0101
2 O-ring
50 x 2 mm
1.97 x 0.08 inch
N007.0501
3 Replacement filter element
(with seal)
s. Chart / col. 9
4 Clogging indicator
(with seal)
s. catalog sheet
60.40
The functions of the complete filters as well as the outstanding
features of the filter elements assured by ARGO-HYTOS can only
be guaranteed if original ARGO-HYTOS spare parts are used.
Quality Assurance
Quality management according to DIN EN ISO 9001
To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to
the following ISO standards:
ISO 2941 Verification of collapse / burst pressure rating
ISO 2942 Verification of fabrication integrity (Bubble Point Test)
ISO 2943 Verification of material compatibility with fluids
ISO 3968 Evaluation of pressure drop versus flow characteristics
ISO 16889 Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity)
ISO 23181 Determination of resistance to flow fatigue using high viscosity fluid
Before release into the series production the filter casing is tested for fatigue strength in our pressure pulse test rig.
Various quality controls during the production process guarantee the leakfree function and solidity of our filters.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet.
Symbols
Subject to change · 30.10-EN/US · 0818
1 32
2
3
1
4
P
1
P
2