Page 286
www.argo-hytos.com
Selection Chart
Part No.
Nominal flow rate
Pressure drop see
diagram D/curve no.
Filter fineness see diagr. Dx
Dirt-holding capacity
Connection A/B
Cracking pressure of by-pass
Symbol
Replacement filter element
Part No.
Weight
Clogging indicator
Remarks
gpm g SAE psi lbs
1 2 3 4 5 6 7 8 9 10 11 12
D 162-753 22.5 D1/1 5EX2 24 -20
2
51 1 V3.0817-03 5.3 retrofittable -
D 162-756
1
37.0 D1/2 10EX2 33 -20
2
51 1 V3.0817-06 5.3 retrofittable -
D 162-758
1
52.8 D1/3 16EX2 33 -20
2
51 1 V3.0817-08 5.3 retrofittable -
D 162-751 58.1 D1/4 30P 18 -20
2
51 1 P3.0817-01
4
5.3 retrofittable -
D 162-783 42.3 D1/5 5EX2 24 -20
2
101 1 V3.0817-03 5.3 retrofittable -
D 162-786 66.0 D1/6 10EX2 33 -20
2
101 1 V3.0817-06 5.3 retrofittable -
D 232-753 31.7 D2/1 5EX2 33 -20
2
51 1 V3.0823-03 7.5 retrofittable -
D 232-756
1
51.5 D2/2 10EX2 47 -20
2
51 1 V3.0823-06 7.5 retrofittable -
D 232-758
1
72.6 D2/3 16EX2 48 -20
2
51 1 V3.0823-08 7.5 retrofittable -
D 232-751 74.0 D2/4 30P 26 -20
2
51 1 P3.0823-01
4
7.5 retrofittable -
D 232-783 58.1 D2/5 5EX2 33 -20
2
101 1 V3.0823-03 7.5 retrofittable -
D 232-786 79.3 D2/6 10EX2 47 -24
3
101 1 V3.0823-06 7.5 retrofittable -
D 332-753 44.9 D3/1 5EX2 49 -20
2
51 1 V3.0833-03 8.8 retrofittable -
D 332-756
1
72.6 D3/2 10EX2 67 -20
2
51 1 V3.0833-06 8.8 retrofittable -
D 332-758
1
74.0 D3/3 16EX2 68 -20
2
51 1 V3.0833-08 8.8 retrofittable -
D 332-751 92.5 D3/4 30P 34 -24
3
51 1 P3.0833-01
4
8.8 retrofittable -
D 332-783 74.0 D3/5 5EX2 49 -20
2
101 1 V3.0833-03 8.8 retrofittable -
D 332-786 92.5 D3/6 10EX2 67 -24
3
101 1 V3.0833-06 8.8 retrofittable -
1
Preferred type, no minimum order quantity required
2
Corresponds to 1
5
/
8
-12 UN-2B
3
Corresponds to 1
7
/
8
-12 UN-2B
4
Paper media supported with metal gauze
Subject to change · 30.30-EN/US · 0818
Optical or electrical clogging indicators are available to monitor the clogging condition of the element. When ordering filters with
integrated monitoring, the abbreviation of the clogging indicator has to be added to the order code of the desired filter variant.
For the appropriate clogging indicator see catalog sheet 60.40.
Oder example: The filter D 162-753 is to be supplied with an optical indicator with automatic reset.
Order code: D 162-753 OD1
Part No. (basic unit)
Clogging indicator
From catalog sheet 60.30, you can see clogging indicators that can be retrofitted.
Remarks:
› The switching pressure of the clogging indicator has always to be lower than the cracking pressure of the by-pass valve
(see Selection Chart, column 7).
› The filters listed in this chart are standard filters. Other designs available on request.
› For versions with electrical clogging indicator, the device socket is not included in the scope of delivery.
› For the electrical clogging indicator of type DIN EN 175301-803 (ED8 and ED9), a device socket with two LEDs is available, which
additionally enables visual indication of the filter contamination (order no. DG 041.1200).