Oil Level Gauges
70.50-4us
C5.3511
·
C5.3516
C5.3529
·
With thermometer
·
Indication range up to 7.64 inch
·
Temperature indication up to 180 °F
Description
Selection Chart
Special features
• The robust metal housing is designed to withstand even the most severe
operating conditions.
• The integrated scale shows the oil temperature in °C and °F.
Mounting
The hollow screws and the locking nuts supplied with the gauge, enable
installation on the reservoir wall.
The locking nuts serve the purpose of retightening the bolts from the
outside (assembly torque: 8 Nm).
Threaded holes are required instead of smooth bore holes if the wall of the
reservoir is more than 0.33 inch thick.
Application
Indicates the oil level and the oil temperature in hydraulic oil or lubricant
reservoirs.
Design and function
ARGO-HYTOS oil level gauges consist of a robust metal housing equipped
with a sight level tube and built-in thermometer. The uid enters the
thermometer chamber through the mounting bolts, which are hollow.
O-rings provide a seal against the housing and the reservoir wall.
Part No.
Remarks
Total height B
Oil level indicating range E
Weight
Temperature indicating range
Temperature indicating range
Mounting bolts
inch lbs
°C
°Finch
C5.3511-50 1.30 4.25 +20 ... +80 80 ... 180 M10 0.40 -
C5.3516-50 2.91 6.26 -10 ... +80 20 ... 180 M12 0.53 -
C5.3529-50 7.64 11.22 -10 ... +80 20 ... 180 M12 0.71 -
1 2 3 4 5 6 7 8
Remarks:
The gauges listed in the chart are standard gauges. If modications are required, we kindly ask for your request.
Dimensions
Measurements
Type A B C D E F G H I K
1
K
2
L
max. mm mm
C5.3511-50 2.99 4.25 1.36 0.89 1.30 0.63 0.67 1.10 0.31 AF 17 AF 15 M10
C5.3516-50 5.0 6.26 1.36 1.08 2.91 0.63 0.67 1.10 0.31 AF 17 AF 18 M12
C5.3529-50 10.0 11.26 1.36 1.22 7.64 0.63 0.67 1.10 0.31 AF 17 AF 18 M12
F
D
B
A
E
K
2
C
I
L
G
H
K
1
ARGO-HYTOS
Black mark for
maximum oil level
Red mark for
minimum oil level
At the housing C5.3529-50 the vision panel is splitted in two sections.
Our engineers will be glad to advise you in questions concerning lter application, selection as well as the cleanliness class of the ltered medium attainable
under practical operating conditions.
Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specication sheet.
Subject to change
70.50-4us · 0714
Characteristics
Quality Assurance
Operating pressure
Max. 29 psi (abs.)
Connection
Threaded ports according to DIN 13. Sizes see
Selection Chart, column 6 and section Dimensions.
Hydraulic fluids
Mineral oil and biodegradable uids
(HEES and HETG, see info-sheet 00.20).
Temperature range
- 4 °F ... + 176 °F
Ambient temperature range
- 13°F ... + 176 °C
Materials
Housing: Steel, powder coated, black
Sight level tube: Polyamide
Scale: Aluminum
Thermometer: Glass
Bolts: Steel, zinc plated
Seals: NBR (FKM on request)
Mounting position
In the min./max. oil level range on the side wall of the hydraulic oil
reservoir.
We produce fluid power solutions
ARGO-HYTOS Inc. · P.O. Box 28 · Bowling Green, OH 43402 · USA
Phone: +1-419-353-6070 · Fax: +1-419-354-3496 · info[email protected] · www.argo-hytos.com
Quality management according to DIN EN ISO 9001
Various quality controls during the production process guarantee the
leakfree function and solidity of our lters.