26 Return to Table of Contents V20.1
Pressure Control
✓Adjustable relief setting from 150 psi to 5000 psi
✓Standard screw adjustment for relief setting. Hand knob available upon request.
✓ Removable NPT orifice plug options
✓ SAE O-ring port for access to NPT orifice and gauging
✓Pressure at Y is directly additive to relief setting
Applications
Relief, Back Pressure, or Sequence Valve
Provides relief function from A to B by connecting the X pilot to the A port of the logic valve. The Y port
can be connected to the B port, but a separate drain connection is preferred. This configuration uses a 1:1
ratio logic valve.
DIN 24342 COVER
FOR PRESSURE CONTROL
SIZES 16mm TO 80mm
5000 PSI
27 Return to Table of Contents V20.1
BL= Include bolts at extra
charge
Blank= Customer will supply
bolts
Custom Orifice Size &/or
Location in “mm”
Example: if desired
orifices are 0.8 mm in X &
1.0 mm in AP, then add:
-08X10AP at end of code
General Layout
Sizes 16mm to 63mm (80mm not shown)
A
B
C
Port Size
Threads in
SAE & AP
*Orifice Size
Bolts
X
AP
2.75”
1.50”
2.1”
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
5/16-18 X 1.50” (4)
3.50"
2.00"
2.1"
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
1/2-13 X 2.00” (4)
4.00"
2.00"
2.1"
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
5/8-11 X 2.00" (4)
5.00"
2.40"
2.1"
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
3/4-10 X 2.50" (4)
5.55"
2.75"
2.1"
SAE #4
1/16-27 NPT
0.7 mm
1.0 mm
3/4-10 X 3.00" (4)
7.00"
3.38"
2.1"
SAE #6
1/8-27 NPT
0.7 mm
1.0 mm
1-1/4-7 X 3.50" (4)
9.50"
3.50"
2.0"
SAE #6
1/8-27 NPT
0.7 mm
1.0 mm
1-8 X 4.00" (8)
*Orifices installed in X SAE port and AP ports only. Other orifice sizes and locations are optional.
*Exception: 25mm has X orifice installed in X port, not X SAE port. AP orifice installed in AP port.
Order Code
AMT-PRC-**-S-**-**
Poppet Relief
Cover
Standard Relief Function
Size: 25, 32, 40, 50, 63, or 80mm
Almo
Manifold
& Tool