46 Return to Table of Contents V20.1
DIN 24342 Active Poppet Valve w/Limit Switch
✓ Standard ISO 7368 & DIN 24342 cavity & porting
✓ Control Areas provide fast response time
✓ Can close poppet under high load pressure
✓ Built-in limit switch provides position feedback of Main Cartridge, AC or DC
Applications
Monitored Active Poppet
The monitored active poppet serves
to add required protection for clamp
circuits. This poppet is pilot operated
to cut off the main hydraulic supply
to the clamp circuit. It is also used for
control press closing.
The monitored active poppet can
meet ISO 13849-1 PLd (Safety Cat.
3) & ISO 13489 PLe (Safety Cat. 4)
when used properly.
Contact our engineering department
to discuss your safety application
needs.
DIN 24342 MONITORED
ACTIVE POPPET
SIZES 16mm TO 50mm
5000 PSI
47 Return to Table of Contents V20.1
General Layout
Sizes 16mm to 50mm
Cover
Size
Flow
B
C
External X &
Y Port Sizes
Internal X &
Y Threads
Bolts
16 mm
80 GPM
3.457”
2.00”
1/16-27 NPT
1/4-20 UNC
5/16-18 X 3.50" (4)
25 mm
100 GPM
3.762”
2.00”
1/16-27 NPT
1/4-20 UNC
1/2-13 X 3.50" (4)
32 mm
200 GPM
4.00”
2.00”
1/16-27 NPT
1/16-27 NPT
5/8-11 X 4.00" (4)
40 mm
350 GPM
5.50”
2.00”
SAE #4
1/16-27 NPT
3/4-10 X 5.00" (4)
50 mm
450 GPM
6.25”
2.00”
SAE #4
1/16-27 NPT
3/4-10 X 6.50" (4)
Order Code
AMT-MAP-**-*-**
Size: 16, 25, 32, 40, or 50mm
BL= Include bolts at
extra charge
Blank= Customer will
supply bolts
Almo
Manifold
& Tool
Blank = Aluminum (pressure ≤ 3,000 psi)
D = Ductile iron (pressure ≤ 5,000 psi)
Monitored
Active
Poppet