44 Return to Table of Contents V20.1
DIN 24342 Active Poppet Valve w/Directional Control
✓ Standard ISO 7368 & DIN 24342 cavity & porting
✓ Control Areas provide fast response time
✓ Can close poppet under high load pressure
✓ Allows pilot-to-open/pilot-to-close
✓ Proportional option without feedback
Applications
Active Directional Control Poppet
The active directional control poppet is pilot operated to cut off the main hydraulic supply to the circuit.
The directional control valve regulates when the poppet is open or closed. The directional control (D03)
valve can receive the pilot pressure internally or externally. The D03 valve can also be internally or
externally drained.
The active directional control poppet can be used in a variety of applications, including: prefill valve,
pilot operated check, proportional flow control valve, etc.
DIN 24342 ACTIVE
DIRECTIONAL CONTROL
POPPET
SIZES 16mm TO 50mm
5000 PSI
Left: Active
directional control
poppet and cover
with a D03 valve
Right: Active
directional control
poppet and cover
with a proportional
D03 valve
45 Return to Table of Contents V20.1
General Layout
Sizes 16mm to 50mm
Flow
A
B
X & Y SAE
Port Sizes
Internal X &
Y Threads
Bolts
80 GPM
2.75”
3.13”
SAE #4
1/4-20 UNC
5/16-18 X 3.50” (4)
100 GPM
3.50”
3.30”
SAE #4
1/4-20 UNC
1/2-13 X 3.50” (4)
200 GPM
4.00”
3.40”
SAE #4
1/16-27 NPT
5/8-11 X 3.50” (4)
350 GPM
5.00”
4.61”
SAE #4
1/16-27 NPT
3/4-10 X 4.50” (4)
450 GPM
5.55”
6.00”
SAE #4
1/16-27 NPT
3/4-10 X 5.00” (4)
Order Code
AMT-ACTD03-**-**
BL= Include bolts at
extra charge
Blank= Customer will
supply bolts
Almo
Manifold
& Tool
Active Poppet &
Cover with D03
Interface
Size: 16, 25, 32, 40, or 50mm