Bi-Directional Valve
β Shuttle valve senses the greater of two pressures
β Standard D03 or D05 interface
β Standard orifice installed in P port
β Removable orifice plug options
Applications
On/Off Valve
Will hold valve closed in one condition & will allow
valve to open in the other condition.
Senses the greater of two pressures between the X port
& the Z1 port. The X port should be connected to the B
port (side of the logic valve), & the Z1 port should be
connected to the A port (nose of the logic valve.
By using a standard D03 directional control valve with
flow from P to A in the de-energized condition, the
shuttle will use the greater pressure to hold the valve
closed. Energizing the solenoid vents the pressure
above the valve insert to the drain. Flow can travel
freely from A to B or from B to A as long as the spring
force is overcome.
B to Z2 allows control of additional valve at Port 1.