1
1
F
UNCTIONAL SCHEME - example of configuration 70
Pilot valve
Main stage
Pressure reducing valve
Plug to be added for external pilot trough port X
Plug to be removed for internal drain through port T
H
YDRAULIC OPTIONS
1
1.1 Option /B
S
olenoid, integral electronics and position transducer at side of port B of the main stage.
For hydraulic configuration vs reference signal, see section 10.1
11.2 Option /G
Pressure reducing valve with fixed setting, installed between pilot valve and
m
ain body. Reduced pressure setting:
40 bar for DPZ
O-1 and DPZO-2
100 bar for DPZO-4(M), DPZO-6 and DPZO-8
It is advisable for valves with internal pilot in case of system pressure higher than
200 bar.
Pressure reducing valve is standard for DPZO-1, for other sizes add /G option.
1
1.3 Pilot and drain configuration
The pilot / drain configuration can be modified as shown in the functional scheme
here aside, for detailed view of plugs position, see section
The valve’s standard configuration provides internal pilot and external drain.
For different pilot / drain configuration select:
Option /E External pilot (through port X)
Option /D Internal drain (through port T)
17
1
2
ELECTRONIC OPTIONS
S
tandard driver execution provides on the 7 pin main connector:
P
ower supply - 24 V
DC m
ust be appropriately stabilized or rectified and filtered; 2,5 A fuse time lag is required in series to each driver
p
ower supply. Apply at least a 10000 mF/40 V capacitance to single phase rectifiers or a 4700 mF/40 V capacitance to
three phase rectifiers
Reference input signal - analog differential input with ±10 V
DC nominal range (pin D, E), proportional to desired valve spool position
Monitor output signal - analog output signal proportional to the actual valve’s spool position with ±10V
D
C
nominal range
Note: a minimum booting time between 400 and 800 ms has be considered from the driver energizing with the 24 VDC power supply before the valve
h
as been ready to operate. During this time the current to the valve coils is switched to zero
.
12.1 Option /F
It provides a Fault output signal in place of the Monitor output signal, to indicate fault conditions of the driver (cable interruption of spool tran-
sducers or reference signal - for /I option): Fault presence corresponds to 0 V
DC, normal working corresponds to 24 VDC
12.2 Option /I
It provides 4 ÷ 20 mA current reference and monitor signals, instead of the standard ±10 V.
Input signal can be reconfigured via software selecting between voltage and current, within a maximum range of ±10 V or ±20 mA.
It is normally used in case of long distance between the machine control unit and the valve or where the reference signal can be affected by
electrical noise; the valve functioning is disabled in case of reference signal cable breakage.
12.3 Option /Q
To enable the driver, supply 24 V
DC on pin C referred to pin B: Enable input signal allows to enable/disable the current supply to the solenoid,
without removing the electrical power supply to the driver; it is used to maintain active the communication and the other driver functions when
the valve has to be disabled. This condition does not comply with European Norms EN13849-1 (ex EN954-1).
12.4 Option /Z
It provides, on the 12 pin main connector, the following additional features:
Enable Input Signal
To enable the driver, supply 24 V
DC on pin 3 referred to pin 2: Enable input signal allows to enable/disable the current supply to the solenoid,
without removing the electrical power supply to the driver; it is used to maintain active the communication and the other driver functions when
the valve has to be disabled. This condition does not comply with European Norms EN13849-1 (ex EN954-1).
Fault Output Signal
Fault output signal indicates fault conditions of the driver (solenoid short circuits/not connected, reference signal cable broken for 4÷20mA
input, etc.). Fault presence corresponds to 0 V
DC, normal working corresponds to 24 VDC (pin 11 referred to pin 2): Fault status is not affected
by the Enable input signal
Power supply for driver’s logics and communication - only for LES
Separate power supply (pin 9,10) allow to cut solenoid power supply (pin 1,2) while maintaining active diagnostics, USB and fieldbus communication.
A safety fuse is required in series to each driver power supply: 500 mA fast fuse.
12.5 Options /C - only for SP, SF, SL
Option /C is available to connect pressure (force) transducers with 4 ÷ 20 mA current output signal, instead of the standard ±10 V.
Input signal can be reconfigured via software selecting between voltage and current, within a maximum range of ±10 V or ±20 mA.
12.6 Possible combined options
For SN: /FI, /IQ and /IZ
For SP, SF, SL: /CI