Size
16 25 32 40 50 63 80 100 125
250
500
800
1200
2000
3000
4500
7200
9350
350 700 1100 1700 2800 4250 6350 10200 13200
600 1200 1800 2500 4000 6000 10000 16000 22000
Max pressure
[bar]
Ports A, B = 420 X = 350 Y 울 10
Nominal flow of pilot valve at Δp = 70 bar
[l/min]
4 8 20 40 40 100 100 100 100
Leakage of pilot valve at P = 100 bar [l/min] 0,2 0,2 0,3 0,7 0,7 1 1 1 1
Piloting pressure [bar] min: 40% of system pressure max 350 recommended 140 ÷ 160
Piloting volume [cm
3
] 1,6 2,2 7,0 9,4 17,7 32,5 39,5 49,5 124,9
Piloting flow (1) [l/min]
4 5,3 14 19 35,5 56 60 60 88,1
Response time 0 ÷ 100% step signal (2) [ms]
24 25 28 30 30 35 40 50 90
Hysteresis [% of the max regulation]
≤ 0,1
Repeatability [% of the max regulation] ± 0,1
Thermal drift
zero point displacement < 1% at ΔT = 40°C
FS330
10
HYDRAULIC CHARACTERISTICS - based on mineral oil ISO VG 46 at 50 °C
11
ELECTRICAL CHARACTERISTICS
Note:
a maximum time of 800 ms (1000 ms just for size 125), depending on communication type, has to be considered between the driver energizing
with the 24 VDC power supply and when the valve is ready to operate. During this time the current to the valve coils is switched to zero.
(1) With step reference input 0÷100% (2) With pilot pressure = 140 bar, see datailed diagrams in section 13.2
Δp = 5 bar
Δp = 10 bar
Max permissible flow
Nominal flow Δp A-B
[l/min]
9
GENERAL CHARACTERISTICS
Power supplies
Nominal : +24 V
DC
Rectified and filtered : VRMS = 20 ÷ 32 VMAX (ripple max 10 % VPP)
Max power consumption 50 W
Max. solenoid current 2,6 A
Coil resistance R at 20°C
3 ÷ 3,3
Ω
Analog input signals
Voltage: range ±10 V
DC (24 VMAX tolerant) Input impedance: Ri > 50 kΩ
Current: range ±20 mA Input impedance: Ri = 500 Ω
Monitor outputs
Output range: voltage ±10 V
DC @ max 5 mA
current ±20 mA @ max 500 Ω load resistance
Enable input
Range: 0 ÷ 5 V
DC (OFF state), 9 ÷ 24 VDC (ON state), 5 ÷ 9 VDC (not accepted); Input impedance: Ri > 10 kΩ
Fault output
Output range: 0 ÷ 24 V
DC (ON state > [power supply - 2 V] ; OFF state < 1 V ) @ max 50 mA;
external negative voltage not allowed (e.g. due to inductive loads)
Alarms
Solenoid not connected/short circuit, cable break with current reference signal, over/under temperature,
valve spool transducer malfunctions, alarms history storage function
Insulation class
H (180°) Due to the occurring surface temperatures of the solenoid coils,
the European standards ISO 13732-1 and EN982 must be taken into account
Protection degree to DIN EN60529 IP66 / IP67 with mating connectors
Duty factor Continuous rating (ED=100%)
Tropicalization Tropical coating on electronics PCB
Additional characteristics
Short circuit protection of solenoid’s current supply; 3 leds for diagnostic (only for LES); poppet position
control by P.I.D. with rapid solenoid switching; protection against reverse polarity of power supply
Communication interface
USB
Atos ASCII coding
IO-Link
Interface and System
Specification 1.1.3
CANopen
EN50325-4 + DS408
PROFIBUS DP
EN50170-2/IEC61158
EtherCAT
POWERLINK
EtherNet/IP
PROFINET IO RT/IRT
IEC 61158
Communication physical layer
not insulated
USB 2.0 + USB OTG
SDCI
class port B
optical insulated
CAN ISO11898
optical insulated
RS485
Fast Ethernet, insulated
100 Base TX
Recommended wiring cable
LiYCY shielded cables, see section
21
Assembly position Any position
Subplate surface finishing to ISO 4401
Acceptable roughness index: Ra ≤ 0,8, recommended Ra 0,4 – Flatness ratio 0,01/100
MTTFd values according to EN ISO 13849 75 years, for further details see technical table P007
Ambient temperature range
Standard = -20°C ÷ +60°C /PE option = -20°C ÷ +60°C /BT option = -40°C ÷ +60°C
Storage temperature range
Standard = -20°C ÷ +70°C /PE option = -20°C ÷ +70°C /BT option = -40°C ÷ +70°C
Surface protection
Zinc coating with black passivation, galvanic treatment (driver housing)
Corrosion resistance
Salt spray test (EN ISO 9227) > 200 h
Vibration resistance See technical table G004
Compliance
CE according to EMC directive 2014/30/EU (Immunity: EN 61000-6-2; Emission: EN 61000-6-3)
RoHS Directive 2011/65/EU as last update by 2015/863/EU
REACH Regulation (EC) n°1907/2006