HC7 miniBOOSTER
Description
The HC7 is a very compact high- pressure unit capable of delivering pressure up to 2,000 bar weighing only 1.5 kg. It is ideal for use in portable
applications like on power packs.
The HC7 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the
high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. With the choice of different high- pressure
adapters, a variety of threads can be obtained from the M22x1.5 thread in the HP port. Higher pressure is available on request.
Flow rates
Intensification factor
i
Max. outlet flow
l/ min
Max. inlet flow
l/ min
5.0 1.6 14.0
6.6 1.3 13.0
9.0 0.9 13.0
13.0 0.6 12.0
20.0 0.3 12.0
Functions
The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the
check valves KV1, KV2 and DV to the high- pressure side H. In this condition maximum flow through the booster is achieved, giving a fast-
forward function.
When pump pressure is reached on the high- pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the
oscillating pump unit OP. The unit will automatically stall when end pressure on the high- pressure side H is reached. If a pressure drop on the
high- pressure side exists due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.
HC7 versions: 5 different intensification factors
P
IN
: 20 207 bar (inlet pressure)
P
H
: 2000 bar maximum (outlet pressure)
P
RETURN
: As low as possible (return pressure to tank)
P
OUTLET
: P
H
= (P
IN
P
Return
) x i (intensification)
Mounting: Inline tube
Accessories: Pilot- operated dump valve incorporated
A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled
miniBOOSTER Hydraulics A/ S, Fynsgade 3, DK - 6400 Sønderborg, Tel: + 45 7442 9292
© 2016 COPYRIGHT MINIBOOSTER HYDRAULICS A/ S
Function diagram
Function diagram 7-105-00
Dimensions
Dimension drawing 7-120-09
Connection types
Connection IN / R
1 1/4" BSPP
2 7/16-20" UNF
Max. tightening torque BSPP
IN / R
1/4" BSPP
with steel washer 4.0 da/ Nm
with aluminium washer 3.0 da/ Nm
with cutting edge 4.0 da/ Nm
Max. tightening torque UNF
IN / R
7/16-20" UNF
with o- ring 2.0 da/ Nm
miniBOOSTER Hydraulics A/ S, Fynsgade 3, DK - 6400 Sønderborg, Tel: + 45 7442 9292
© 2016 COPYRIGHT MINIBOOSTER HYDRAULICS A/ S
High- pressure adapters
Ordering code Male connection 1 Connection 2 Max. pressure
7-432 M22 x 1.5 9/16-18 UNF 3,000 bar
7-433 M22 x 1.5 1/4" BSPP 3,000 bar
7-434 M22 x 1.5 Plug 3,000 bar
7-435 M22 x 1.5 1/4" BSPP 800 bar
7-439 M22 x 1.5 9/16-18 UNF 1,380 bar
7-445 M22 x 1.5 1/4" BSPP male 3,000 bar
7-446 M22 x 1.5 M22 x 1.5 3,000 bar
7-447 M22 x 1.5 7/16-20 UNF 1,380 bar
High- pressure adapter ordering codes and specifications can be seen from the table in the PDF- file below:
High- pressure adapters: 7-900-06
Fluids and materials
Please see: General specifications
Ordering an HC7
Ordering example of an HC7 with i = 13.0, H1 M22 x 1.5 and H2 9/16-18 UNF,
DV incorporated and BSPP connections: HC7 - 13.0 - B - 12
Please note!
High- pressure adapter ordering code see table
Model Intensification, i Dump valve Connections
HC7 your selection... your selection... see table below
see flow rate table A = (no) / A model
B = (yes) / B model
G = (proportional) / G model
Ordering code IN, R H1 H2 H3
HC7- ___- __-11 1/4" BSPP M22 x 1.5
HC7- ___- __-21 7/16-20 UNF M22 x 1.5
HC7- ___- __-12 1/4" BSPP M22 x 1.5 9/16-18 UNF
HC7- ___- __-22 7/16-20 UNF M22 x 1.5 9/16-18 UNF
HC7- ___- __-13 1/4" BSPP M22 x 1.5 9/16-18 UNF 9/16-18 UNF
HC7- ___- __-23 7/16-20 UNF M22 x 1.5 9/16-18 UNF 9/16-18 UNF
miniBOOSTER Hydraulics A/ S, Fynsgade 3, DK - 6400 Sønderborg, Tel: + 45 7442 9292