The HC3- H miniBOOSTER
Description
The HC3 - H is a variant of the HC3 with the topside and the B port closed, not needing a TOP Plate. It is designed for use in NG6 (D03)
stacking manifold systems. The HC3- H is like the other HC3 units a compact unit. The HC3 has the pilot operated dump valve incorporated as a
standard feature. Maximum outlet pressure is 500 bar in standard versions. Adjustments of the outlet pressure is carried out by varying the
supplied pressure.
Flow Rates
Intensification factor
i
Max. outlet flow
l/ min
Max. inlet flow
l/ min
1.2 1.2 8.0
1.5 1.0 8.0
2.0 2.0 12.0
2.8 2.2 13.0
3.2 2.5 15.0
4.0 2.0 14.0
5.0 1.6 14.0
6.6 1.3 13.0
9.0 0.9 13.0
13.0 0.6 12.0
20.0 0.3 12.0
HC3 - H versions: 11 different intensification factors
P
IN
: 20 – 200 bar (inlet pressure)
P
H
: 500 bar maximum (outlet pressure)
P
RETURN
: As low as possible (Return pressure to tank)
Intensification ratios: P
H
= (P
IN
– P
Return
) i (Intensification)
Mounting: NG6 (D03) stacking manifold system
Accessories: Pilot operated dump valve available
A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled