F-50
03 Series Modular Valves
■ Model Number Designation
Model Numbers
Graphic Symbols Graphic Symbols
MRP-03
MRA-03
MRB-03
Series Number
MRP: Reducing Valve for P-Line
MRA: Reducing Valve for A-Line
MRB: Reducing Valve for B-Line
MRP
A: ★-3.5
B: 1-7
C: 3.5-14
H: 7-31.5
Pres. Adj. Range
MPa
−B
03
Valve
Size
−03
70
Design
Number
−70
T-Line
A&B-Lines
0.5
0.4
0.3
0.2
0.1
0 20 40 60 80 100
P
900
800
700
600
500
400
300
200
100
0 5 10 15 20 25 30
Differential pressure MPa
(Primary pressure-Secondary pressure)
cm
3
/min
Drain Flow Rate
Pres. Drop at Spool Fully Open (P-Line)
1.5
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0 20 40 60 80 100 120
P
30
20
10
5
0
0 20 40 60 80
20 40 60 80 100
MPa
Flow Rate L/min
MR*-03-H
MR*-03-H
MR*-03-H
MR*-03-C
MR*-03-B
MR*-03-B
MR*-03-B
MR*-03-A
MR*-03-A
Secondary Pressure
Reducing Modular Valves
■ Instructions
The minimum adjustment pressure equals the value obtained from the minimum
adjustment pressure characteristics plus the tank line back pressure of this page.
This back pressure should include the value of the T-line pressure drop
characteristics of the valves stacked to the base plate side of the modular valve.
To make pressure adjustment, loosen the lock nut and turn the pressure
adjustment screw clockwise or anti clockwise. For an increase of pressure, turn
the screw clockwise. Be sure to re-tighten the lock nut firmly after making
adjustment to the pressure.
■ Specifications
Model Numbers
Max. Operating Pressure
MPa
Max.Flow
L/min
MR*-03-A-70
★
35
80
MR*-03-B/C/H-70 120
★If the pressure is set below 1.2 MPa, the maximum flow is limited.
See the "Min. Adjustment Pressure vs. Max. Flow" of this page.
★See the "Min. Adjustment Pressure vs. Max. Flow" of this page.
Min. Adjustment Pressure vs. Max. FlowNominal Override Characteristics
Primary Pressure 35 MPa
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0 20 40 60
80
Flow Rate L/min
MPa
Min. Adjustment Pressure
■ Typical Performance Characteristics
Hydraulic Fluid: Viscosity 35 mm²/s, Specific Gravity 0.850