PRESSURE CONTROLS
C-19
C
Solenoid Controlled Relief Valves
Solenoid Controlled Relief Valves
SOL a
SOL b
Lock Nut
14 Hex.
Two Collars
Position can be shifted
by 90° steps.
Solenoid Indicator Light
Pressure Adjustment Handle
INC.
Vent Port
Rc 3/8 Thd.
Tank Port
Rc “X ” Thd.
Remote Control Port
“B” Rc 1/8 Thd.
Pressure Port
Rc “X” Thd.
2 Places
Pressure Gauge Connection
Rc 1/4 Thd.
Remote Control Port
“A” Rc 1/8 Thd.
Manual Actuator
6 Dia. Through
Electrical Conduit Connection
G 1/2 Thd. (Both Ends)
AC :45.5
DC/R :50
AC :196.4
DC/R :204.4
47.5
47.5
K
L
Space Needed to Remove Solenoid-Each End
V
U
T
Q
S
P
N
44 Dia.
Fully Extended H
F
E
D
J
“C” SQ.
46
AC :98.2
DC/R :102.2
★2
★1
■ Option
● Models with Vent Restrictor
The type with a vent restrictor has a vent restrictor in vent types
2B3A and 2B3B added between a relief valve and a solenoid
operated directional valve. If prevents shock to the main circuit by
gradually lowering the venting pressure in the shift from the set
pressure to unloading.
Unloading pressure are the same as without a vent restrictor.
■ Instructions
● If a remote control relief valve is used in the vent circuit, see page
C-3. In addition, if the internal volume of the vent line is too large,
chattering is likely to occur. Thus, as far as possible reduce the inside
diameter and the length of the pipe.
● To adjust the pressure, loosen the lock nut and turn the handle slowly
clockwise for higher pressures or anti-clockwise for lower pressures.
Pressure change of one handle revolution is about 5 MPa. After
adjustments, do not forget to tighten the lock nut.
● Piping of the tank line should not be connected to any tank line of the
other valves, but connected directly to the reservoir.
● With a small flow, the setting pressure may be unstable. Use with the
minimum flow rate as the below chart.
Valve Size Min. Flow
03
06
10
8 L/min
15 L/min
BST
−
03, 06, 10
A
−
BS*
−
*
−
2B3A A
−
BS*
−
*
−
2B3B
★1. Pressure is limited by collars fitted. If a working pressure cannot be
attained, remove some collars. One collar is equivalent to 10 MPa.
★2. There are two threaded connection pressure ports. They can be
connected each other in-line; one as inlet and the other as an outlet
or the valve can be used by plugging one of the pressure ports.
Model Numbers
C D E F H J K N P Q S T U V X
BST
−
03
BST
−
06
BST
−
10
75
85
L
40
50
52
80
78
96
145
151
52
80
45
60
90
120
239.3
271.8
68.5
89
152.5
164.5
36
49
105.5
117.5
69
81
62
74
3
/
8
3
/
4
1
1
/
4
Models with Vent
Restrictor (Option)
A
−
BST
−
03, 06, 10
Models with Plug-in Connector (Option)
03
BST
−
06
−
*
−
*
−
*
−
N
10
Model Numbers
Y Z d
A
−
BST
−
03
A
−
BST
−
06
A
−
BST
−
10
269.3
301.8
182.5
194.5
135.5
147.5
For other dimensions, see
the above figure.
Name
Coil
Type
e f h
AC Solenoid
DC Solenoid
R (AC
→
DC)
Solenoid
A*
D*
R*
53
64
57.2
65
76
79
39
39
53
For other dimensions, see the above figure.
SOL b
DC/R :102.2
d
Z
SOL a
SOL b
AC :196.4
DC/R :204.4
51 51 h
e
f
Cable Applicable:
Outside Dia. ..... 8-10mm
Conductor Area .....