Valve Name
SRT-03-50/5080/5090
SRT-06-50/5080/5090
SRT-10-50/5080/5090
SRCT-03-50/5080/5090
SRCT-06-50/5080/5090
SRCT-10-50/5080/5090
Restrictor
One Way Restrictor
Model Numbers
Threaded Connection Sub-plate Mounting
Max.
Operating
Pres.
MPa (PSI)
L/min
(U.S.GPM)
Rated Flow
Threaded
Connection
Sub-plate
Mounting
Approx. Mass
kg (lbs.)
30 (7.9)
85 (22.4)
230 (60.7)
30 (7.9)
85 (22.4)
230 (60.7)
1.5 (3.3)
3.8 (8.4)
9.1 (20.1)
1.5 (3.3)
3.8 (8.4)
9.1 (20.1)
SRG-03-50/5090
SRG-06-50/5090
SRG-10-50/5090
SRCG-03-50/5090
SRCG-06-50/5090
SRCG-10-50/5090
25 (3630)
25 (3630)
2.5 (5.5)
3.9 (8.6)
7.5 (16.5)
2.5 (5.5)
3.9 (8.6)
7.5 (16.5)
Rated flow stands for approximate flow rate when the pressure
drop between inlet and outlet ports of the valve in fully opened
condition becomes 0.3 MPa (44 PSI) maximum at fluid's specific
gravity of 0.85 and kinematic viscosity of 20 mm
2
/s (98 SSU).
Max. Operating
Pressure
MPa (PSI)
Rated Flow
L/min
(U.S.GPM)
Model Numbers
SRF/SRCF-10-50
SRF/SRCF-10-5090
25 (3630)
SRF/SRCF-16-50
SRF/SRCF-16-5090
230 (60.7)
500 (132)
Yuken can offer flanged connection valves described below.
For details, contact us.
Special Seals
for Phosphate
Ester Type
Fluids
(Omit if not
required)
F:
03
06
10
03
06
10
03
06
10
03
06
10
Restrictor
SR:
One Way
Restrictor
SRC:
Threaded Connection
T:
Sub-plate Mounting
G:
Threaded Connection
T:
Sub-plate Mounting
G:
50
50
50
50
50
50
50
50
50
50
50
50
F- SR
Special Seals Series Number
T
Type of Mounting
-50
Design Number Design Standards
-03
Valve Size
None:
Japanese Std. "JIS"
80:
European Design Std.
90:
N.American Design Std.
None:
Japanese Std. "JIS"
80:
European Design Std.
90:
N.American Design Std.
None:
Japanese Std. "JIS" &
European Design Std.
90:
N.American Design Std.
None:
Japanese Std. "JIS" &
European Design Std.
90:
N.American Design Std.
Model Number Designation
Specifications
Restrictors / One Way Restrictors
This valve is used to regulate an actuator speed in a circuit where line pressure is almost steady and small fluctuation
of oil flow due to pressure changes is permitted. Integrated check valve allows reversed free flow from outlet to inlet
port. Pressure balanced construction provides less effort in adjustment at high pressure.
Graphic Symbols
SRT/SRG SRCT/SRCG
SRT/SRG SRCT/SRCG