Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Solenoid Controlled Pilot Operated Directional Valves
These valves are composed of a solenoid operated pilot valves and a pilot operated slave valve. When a solenoid is
energised the pilot valve directs the flow to move the spool of the slave valve, thus changing the direction of flow in
the hydraulic circuit.
High Pressure High Flow
High pressure [315 Kgf/cm
2
] along with
high flow means compact system design.
Lower pressure Drop
System energy saving increased as pressure
drop of each valve has greatly reduced.
Valve
Type
Model Numbers
*1
Max.
Flow
L/min
Max.
Operating
Pressure
Kgf/cm
2
Max. Pilot
Pressure
Kgf/cm
2
Min.
*2
Required
Pilot Pres.
Kgf/cm
2
Max. T-Line Back
Pressure Kgf/cm
2
Max.
Changeover
Frequency
Cycles/min
Mass
Kg
Ext. Drain
Int. Drain
AC DC R
Standard
Type
Shockless
Type
(S)-DSHG-04-3C - -50
300 315 250 8 210 160 120 120 120
8.8
(S)-DSHG-04-2N - -50
8.8
(S)-DSHG-04-2B - -50
8.2
(S)-DSHG-06-3C - -51
500 315
250 8
210 160
120 120 120
12.7
(S)-DSHG-06-2N - -51
12.7
(S)-DSHG-06-2B - -51
12.1
(S)-DSHG-06-3H - -51
210 10 110 110 110 13.5
(S)-DSHG-10-3C - -41
1100 315
250
10 210 160
120 120 100 45.3
(S)-DSHG-10-2N - -41
100 100 100 45.3
(S)-DSHG-10-2B - -41
210 60 60 50
44.7
(S)-DSHG-10-3H - -41
53.1
Specifications
Maximum flow indicates a ceiling flow. As the ceiling flow
depends on the type of spool and operating condition, refer to the
list of Spool Functions on pages 375 to 377 for details.
Pilot pressure of internal pilot drain models must always exceed
tank line back pressure by a minimum required pilot pressure.
* 1.
* 2.
P T
A B
a b
Y
Graphic symbol
EIC-E-1003-0
372
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Model Number Designation
F- S- DSH G -06 -2 B 2 A
-C2*
-E T
-R2*
-D24 -N -51
-L
Special Seals
Type
Series Number
Type of Mounting
Valve Size
Number of Valve
Positions
Spool-Spring
Arrangement
Spool Type
Special Two
Position Valve
Models with Pilot
Choke Valve
Pilot Connection
Drain Connection
Spool Control
Modification
(Omit if not required)
Coil Type
Type of Electrical
Conduit Con.
Design Number
Mod. With Alternate
Offset Sol.
F:
For
Phos-
phate
Ester
Type
Fluids
None:
Stan-
dard
Type
S:
Shock-
less
Type
DSH:
Solenoid
Con-
trolled
Pilot
Operated
Direc-
tional
Valve.
G:
Sub-
plate
Mount
-ing
04
3
C:
Spring
Centred
2,4,
40,60,
10,12
(3,5,
6,
*1
7,
9,11)
---
C1:
*
With C1
With
Choke
C2:
*
With C2
With
Choke
C1C2:
*
With
C1&C2
Choke
(Omit
if not
Required)
None:
Inter-
nal
Pilot
E:
Exter-
nal
Pilot
None:
Exter-
nal
Drain
T:
Inter-
nal
Drain
R2:
With
Stroke
Adjust-
ment,
Both
Ends
RA:
With
Stroke
Adjust-
ment
Port”A”
End
RB:
With
Stroke
Adjust-
ment
Port “B”
End
AC
A100,
A120
A200,
A240
DC
D12,
D24
D100
*3
ACDC
R110,
R220
None:
Terminal
Box
Type
N:
Plug-in
Con-
nector
Type
N1:
Plug-in
Con-
nector
with
indica-
tior
Light
50
---
2
N:
No-
Spring
2,4,
40,6,
60,9,
12
(3,7)
*1
A
*2
(Omit if
not
Required)
L:
(Omit
if not
Required)
B:
Spring
Offset
2,4,
40,60,
10,12
(3,7)
*1
A
*2
B
*2
(Omit
if not
Required)
06
10
3
C:
Spring
Centred
2,4,
40,60,
10,12
(3,5,
6
*1
7,
9,11)
--- 51
---
2
N:
No-
Spring
2,4,
40
(3,7)
*1
A
*2
(Omit
if not
Required)
41
B:
Spring
Offset
2,4,
40,
(3,7)
*1
A
*2
B
*2
(Omit
if not
Required)
L:
(Omit
if not
Required)
Note : 1. Options are marked with*
2. In spool type “3”,“5”,“6”,“60”and “7”, the combination applicable between pilot system &
drain system is as described in the table below.
*1 Shockless type (S-DSHG) are not available for spool type marked ().
*2 Other spool types for special 2-position valves are available in addition to spool type 2, 3, 4, 40 and 7.
[Refer to the column “valves with centre position and one offset position” (Special 2-position valve) on page 377.
*3 Coil type “R” is not available for plug-in connector with Indicator type”N1".
Model Numbers
Pilot Valve Model
Numbers
Solenoid Rating described on
The page below
(S-)DSHG-04
DSG-01- - -50
EIC-E-1001
Page No.349
(S-)DSHG-06
(S-)DSHG-10
Solenoid Ratings
Solenoid ratings of pilot valve are identical with those of standard
solenoid valve. Refer to relevant solenoid ratings described on the page below.
Pilot connection Drain Connection Care in Application
Internal Pilot
External Drain
Hold back pressure in the tank line so that the
difference between pilot pressure and drain
pressure is always more than minimum
required pilot pressure
Internal Drain (T) Combination not available.
External Pilot
(E)
External Drain
No Limitation in use.
Internal Drain (T)
373
Solenoid Controlled Pilot
Operated Directional Valves
E
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Sub-plates
Mounting Bolts
Valve
Model
Numbers
Sub-plate Model
Numbers
Thread
Size
Approx.
Mass Kg
DSHG-04
DHGM-04-2080 1/2 BSP.F 4.4
DHGM-04X-2080 3/4 BSP.F 4.1
DSHG-06
DHGM-06-5080 3/4 BSP.F
8.5
DHGM-06X-5080 1 BSP.F
DSHG-10
DHGM-10-4080 1-1/4 BSP.F
21.5
DHGM-10X-4080 1-1/2 BSP.F
Sub-plates are available. Specify sub-plate model from the table above. When Sub-plates are not used, the
mounting surface should have a good machined finish.
Model Numbers Name Mounting Bolt Qty.
Mounting Bolt
Ordering Code
DSHG-04 Soc. Hd. Cap. Screw
M6 x 45 Lg. 2
BKDSHG-04-50
M10 x 50 Lg. 4
DSHG-06 Soc. Hd. Cap. Screw M12 x 60 Lg. 6 BKDSHG-06-51
DSHG-10 Soc. Hd. Cap. Screw M20 x 75 Lg. 6 BKDSHG-10-41
Options
Models with Pilot Choke Adjustment
(C1/C2/C1C2)
By turning the adjusting screw
clockwise, main spool changeover
speed by the pilot pressure can be
lowered. But centering speed of
spring centered modes can not be
changed.
When the adjusting screw is turned
clockwise, main spool changeover
speed can be lowered and centering
speed of spring centered models
can be also lowered.
“C1” Models ---
“C2” Models ---
Models with Pilot Stroke Adjustment
(R2/RA/RB)
When the adjusting screw is screwed in, the
main spool stroke becomes short and flow rate
reduces.
Additional Mass of Options
Add mass of options described below to mass
of standard type if options are used.
Model Numbers
Models with Pilot
Choke Adj.
Models With
Stroke Adj.
C1,C2 C1C2 R2
RA
RB
(S-)DSHG-04 0.65 1.3 1.0 0.5
(S-)DSHG-06 0.65 1.3 1.2 0.6
(S-)DSHG-10 0.65 1.3 3.7 1.85
ba
A B
P
T
Y
C1 Choke
C2 Choke
Graphic symbols (Ex. Spring Centered)
“RB” Models
“RA” Models
“R2” Models
Graphic symbols (Ex. Spring Centered)
374
P T
A B
a b
P T
A B
a b
P
T
A B
a b
Y
Y
Y
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
List of Spool Functions (DSHG-04/S-DSHG-04)
Three Positions
100
Kgf/cm²
Spring Centered
Maximum Flow
L/min.
P T
A B
a b
Graphic Symbol
"2"
"3"
"4"
"40"
"5"
"6"
"60"
"7"
"9"
"10"
"11"
"12"
Spool Type
300 300 200
120250300
DSHG-04-3C2
DSHG-04-3C3
DSHG-04-3C4
DSHG-04-3C40
DSHG-04-3C5
DSHG-04-3C6
DSHG-04-3C60
DSHG-04-3C7
DSHG-04-3C9
DSHG-04-3C10
DSHG-04-3C11
DSHG-04-3C12
S-DSHG-04-3C2
Y
Model Numbers
145
110
300 300 300 300
250300300 165
140300300 110
120250300 110
300 300 200 145
250 250 245 245
300 260
245 235
300 300 300 300
300 300 200 145
300 300 280 250
300 300 200 150
300 250 120 110
300 260 160 140
300 280 170 135
300 250 120 110S-DSHG-04-3C12
S-DSHG-04-3C10
S-DSHG-04-3C60
S-DSHG-04-3C4
S-DSHG-04-3C40
160
Kgf/cm²
250
Kgf/cm²
315
Kgf/cm²
100
Kgf/cm²
No-Spring
Maximum Flow
L/min.
P T
A B
a
Graphic Symbol
"2"
"3"
"4"
"40"
"7"
Spool Type
(S-)DSHG-04-2N2
DSHG-04-2N3
(S-)DSHG-04-2N4
(S-)DSHG-04-2N40
DSHG-04-2N7
Spring Offset
Maximum Flow
L/min.
Graphic Symbol
(S-)DSHG-04-2B2
DSHG-04-2B3
(S-)DSHG-04-2B4
(S-)DSHG-04-2B40
DSHG-04-2B7
300
b
b
P T
A B
Y
Y
300 300 300
300 300 300 300
300 300 300 300
300 300 300 300
300 300 300 300
300 300 300 300
300 300 300 300
300 300 300 300
300 300 300 300
300 300 300 300
160
Kgf/cm²
250
Kgf/cm²
315
Kgf/cm²
100
Kgf/cm²
160
Kgf/cm²
250
Kgf/cm²
315
Kgf/cm²
Note:
1 Max. Flow described above shows value at pilot pressure more than 6 Kgf/cm
2
.
2 Max. Flow shows value at the condition of the flow as shown in right figure
P→A→B→T (or P→B→A→T).
Max. Flow differs according to hydraulic circuit, if port “A” or “B” is blocked.
Consult Yuken for such application.
3 For values in the double row, upper is maximum flow at pilot pressure 5Kgf/cm
2
.
(In case pressure centered model, pilot pressure is 5 Kgf/cm
2
),
lower is pilot pressure of 7 Kgf/cm
2
.
Two Positions
a b
P T
A B
375
Solenoid Controlled Pilot
Operated Directional Valves
E
List of Spool Functions (DSHG-06/S-DSHG-06)
Three Positions
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
100
Kgf/cm²
160
Kgf/cm²
250
Kgf/cm²
Spring Centered
P T
A B
a b
Graphic Symbol
"2"
"3"
"4"
"40"
"5"
"6"
"60"
"7"
"9"
"10"
"11"
"12"
Spool Type
(S-)DSHG-06-3C2
DSHG-06-3C3
(S-)DSHG-06-3C4
(S-)DSHG-06-3C40
DSHG-06-3C5
DSHG-06-3C6
(S-)DSHG-06-3C60
DSHG-06-3C7
DSHG-06-3C9
(S-)DSHG-06-3C10
DSHG-06-3C11
(S-)DSHG-06-3C12
315
Kgf/cm²
Y
Maximum Flow
L/min
100
Kgf/cm²
160
Kgf/cm²
250
Kgf/cm²
Pressure Centered
P T
A B
a b
Graphic Symbol
(S-)DSHG-06-3H2
DSHG-06-3H3
(S-)DSHG-06-3H4
(S-)DSHG-06-3H40
DSHG-06-3H5
DSHG-06-3H6
(S-)DSHG-06-3H60
DSHG-06-3H7
DSHG-06-3H9
(S-)DSHG-06-3H10
DSHG-06-3H11
(S-)DSHG-06-3H12
315
Kgf/cm²
Y
Maximum Flow
L/min
500
500
500
500
500
500
475
475
500
500
500
500
390
420
300
340
230
280
500
500
500
500
500
450 360
450 360
500
500
500
500
500
460 370
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
410 310
500500
500500
500500
500500
500500
500500
410 310
410 310
410 310
410 310
410 310
420
500
500
420
500
420
500
420
500
420
500
460
500
460
500
460
500
500
500
470
500
425 350
500 500
100
Kgf/cm²
160
Kgf/cm²
250
Kgf/cm²
No-Spring
P T
A B
a
Graphic Symbol
"2"
"3"
"4"
"40"
"7"
Spool Type
(S-)DSHG-06-2N2
DSHG-06-2N3
(S-)DSHG-06-2N4
(S-)DSHG-06-2N40
DSHG-06-2N7
Spring Offset
Graphic Symbol
(S-)DSHG-06-2B2
DSHG-06-2B3
(S-)DSHG-06-2B4
(S-)DSHG-06-2B40
DSHG-06-2B7
b b
P T
A B
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
315
Kgf/cm²
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
100
Kgf/cm²
160
Kgf/cm²
250
Kgf/cm²
315
Kgf/cm²
Maximum Flow
L/min
Maximum Flow
L/min
Y Y
Two Positions
Note: 1 Relation between max. flow and pilot pressure is:
Value in the single column is constant regardless of pilot pressure subject to
pilot pressure more than 8 Kgf/cm
2
. In case pressure centered models, pilot
pressure is more than 10 Kgf/cm
2
.
For values in the double row, upper is max. flow at pilot pressure 8 Kgf/cm
2
.
(In case pressure centered models, pilot pressure is 10 Kgf/cm
2
or more.)
Lower is pilot pressure of 15 Kgf/cm
2
.
2 Max. Flow shows value at the condition of the flow as shown in right figure
P→A→B→T (or P→B→A→T).
Max. Flow differs according to hydraulic circuit, if port “A” or “B” is blocked,
consult Yuken for such application.
a b
P T
A B
376
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
List of Spool Functions (DSHG-10/S-DSHG-10)
Three Positions
100
Kgf/cm²
160
Kgf/cm²
250
Kgf/cm²
Spring Centered
P T
A B
a b
Graphic Symbol
"2"
"3"
"4"
"40"
"5"
"6"
"60"
"7"
"9"
"10"
"11"
"12"
Spool Type
(S-)DSHG-10-3C2
DSHG-10-3C3
(S-)DSHG-10-3C4
(S-)DSHG-10-3C40
DSHG-10-3C5
DSHG-06-3C6
(S-)DSHG-10-3C60
DSHG-10-3C7
DSHG-10-3C9
(S-)DSHG-10-3C10
DSHG-10-3C11
(S-)DSHG-10-3C12
315
Kgf/cm²
Y
Maximum Flow
L/min
100
Kgf/cm²
160
Kgf/cm²
250
Kgf/cm²
Pressure Centered
P T
A B
a b
Graphic Symbol
(S-)DSHG-10-3H2
DSHG-10-3H3
(S-)DSHG-10-3H4
(S-)DSHG-10-3H40
DSHG-10-3H5
DSHG-10-3H6
(S-)DSHG-10-3H60
DSHG-10-3H7
DSHG-10-3H9
(S-)DSHG-10-3H10
DSHG-10-3H11
(S-)DSHG-10-3H12
315
Kgf/cm²
Y
Maximum Flow
L/min
950 750
1100
1100
1100
1100
1100
1050
1050
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100 1100
1060 895
950 750
1100 1100
950 750
1100 1100
980 850
880 700 570
940 785 680
1100
950 750
1100 1100
950 750
1100 1100
950 750
1100 1100
1040 870
1040
870
1100 1100
970
1100
1050
1100
970
1100
970
1100
1000
1100
970
1100
970
1100
1060
1100
1060
1100
1060
1100
V
Two Positions
100
Kgf/cm²
160
Kgf/cm²
250
Kgf/cm²
No-Spring
P T
A B
a
Graphic Symbol
"2"
"3"
"4"
"40"
"7"
Spool Type
(S-)DSHG-10-2N2
DSHG-10-2N3
(S-)DSHG-10-2N4
(S-)DSHG-10-2N40
DSHG-10-2N7
Spring Offset
Graphic Symbol
(S-)DSHG-10-2B2
DSHG-10-2B3
(S-)DSHG-10-2B4
(S-)DSHG-10-2B40
DSHG-10-2B7
b b
P T
A B
315
Kgf/cm²
100
Kgf/cm²
160
Kgf/cm²
250
Kgf/cm²
315
Kgf/cm²
Maximum Flow
L/min
Maximum Flow
L/min
Y Y
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
a b
P T
A B
Note :
1 Relation between max. flow and pilot pressure is
Value in the single column is constant regardless of pilot pressure subject to pilot
pressure more than 10 Kgf/cm
2
.
For values in the double row, upper is max. flow at pilot pressure 10 Kgf/cm
2
. Lower is
pilot pressure of 15 Kgf/cm
2
.
2 Max. Flow shows value at the condition of the flow as shown in right figure
P→A→B→T (or P→B→A→T).
Max. Flow differs according to hydraulic circuit, if port “A” or “B” is Blocked,
consult Yuken for such application.
377
Solenoid Controlled Pilot
Operated Directional Valves
E
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Spring Offset Valves with Alternate Solenoid
Though our standard spring offset models use solenoid "b", alternate models using solenoid "a"
are also available. The graphic symbols are expressed as below.
For Models 2B -A and 2B B, refer to table as below.
Valve with Centre Position and One Offset Position (Special Two Position Valve)
In addition to the standard two position valves as shown in the table on pages 375 to 377 two kinds of
valves are available with center position and either one of two offset positions.
Standard and alternate offset types use solenoid “b” and solenoid “a” respectively.
-DSHG-06-2B A
(S-)-DSHG- -2B2A
DSHG- -2B3A
(S-)DSHG- -2B4A
(S-)DSHG- -2B40A
DSHG- -2B5A
DSHG- -2B6A
(S-)DSHG- -2B60A
DSHG- -2B7A
DSHG-
-2B11A
(S-)DSHG-
-2B10A
DSHG- -2B9A
(S-)DSHG-
-2B12A
-DSHG-06-2B B
(S-)-DSHG- -2B2B
(S-)DSHG- -2B4B
(S-)DSHG- -2B40B
DSHG- -2B5B
DSHG- -2B6B
(S-)DSHG- -2B60B
DSHG- -2B7B
DSHG-
-2B11B
(S-)DSHG-
-2B10B
DSHG- -2B9B
(S-)DSHG-
-2B12B
04
10
04
10
-DSHG-06-2N A
04
10
DSHG- -2B3B
(S-)-DSHG- -2N2A
(S-)DSHG- -2N4A
(S-)DSHG- -2N40A
DSHG- -2N5A
DSHG- -2N6A
(S-)DSHG- -2N60A
DSHG- -2N7A
DSHG-
-2N11A
(S-)DSHG-
-2N10A
DSHG- -2N9A
(S-)DSHG-
-2N12A
DSHG-
-2N3A
P T
A B
b
Y
a
YP T
A B
P T
A B
b
Y
a
YP T
A B
P T
A B
b
Y
a
Model Numbers
Graphic Symbols
Standard
Offset
Type
Alternate
Offset
Type
Model Numbers
Graphic Symbols
Standard
Offset
Type
Alternate
Offset
Type
Model Numbers
Graphic Symbols
Standard
Offset Type
P T
A B
b a
YP T
A B
Y
Standard Offset Alternate Offset (“L”)
(Example) In case of spool Type “2”
a
b
P
T
A B
A B
P
T
Center Position
A B
Sol. b energised
Sol. a energised
"A" : (2B2A) "B" : (2B2B)
P
T
b
b
Y
Y Y
378
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Pressure Drop
Spool
Type
PA
Pressure Drop Curve Numbers
BT PB AT PT
Spool
Type
Pressure Drop Curve Numbers
PA BT PB AT PT
2
3
4
40
5
6
60
7
9
10
11
12
5
( 2 )
555 7
5
( 2 )
5
( 2 )
5
( 6 )
3
( 4 )
5
( 6 )
6
( 7 )
1
( 2 )
5
( 2 )
4
( 2 )
5
( 2 )
5
( 5 )
5
( 2 )
2
( 2 )
5
( 2 )
6
( 4 )
3
( 3 )
4
( 4 )
5
( 2 )
5
( 2 )
5
( 5 )
6
( 6 )
4
( 2 )
5
( 2 )
6
( 4 )
7 55
4
5
3
7
4
7
5
6 5 6
6
65
7
4
5 4
5
5
2
Pressure drop curves based on viscosity of 35cSt and specify gravity of 0.850.
Spool
Type
P A B T P B A T P T
Spool
Type
P A B T P B A T P T
Pressure Drop C urve Num bers Pressure Drop Curve Numbers
2
3
4
40
5
6
60
7
9
10
11
12
8 6
( )
8 6
( )
5 2
( )
8 6
( )
7 2
( )
5
1
( )
8 6
( )
7
2
( )
6
7
646
8
8
5
5
5
8
54
1
7
7
4
2
3
5 6
( )
5
2
( )
6 6
( )
7 3
( )
3
1
( )
6
6
6
6
4
4
5
5
5
7
7
7
7
7
8
5
8
8
8
8
Spool
Type
PA BT PB AT PT
Spool
Type
PA BT PB AT PT
Pressure Drop Curve Numbers Pressure Drop Curve Numbers
2
3
4
40
5
6
60
7
9
10
11
12
9 8
( )
( ) ( ) ( ) ( )
6 3
( ) ( ) ( )
67
5
( ) ( ) ( )
5 4
( )
3 2
( )
7
7
8
9 8
9
9
6
6
6
3
5
5
57 7
9 8 8 4
9 8 6 6
9
8
8
6
4
1
2
8 8 5 4 8 8
7
7
7
7
7
7
9
99
9
9
6
6
6
8
5
6
Viscosity
cSt
15 20 30 40 50 60 70 80 90 100
Factor 0.81
0.87
0.96
1.03
1.09
1.14
1.19
1.23
1.27
1.30
1
0
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
0
4
8
12
16
20
200 400 600 800 1000 1100
Flow Rate
Pressure Drop P
Pressure Drop P
0
4
8
12
16
0 100 200 300 400 500
20
L/min
L/min
Flow Rate
Kgf/cm²
Kgf/cm²
0 100
200
2
4
6
8
10
12
Flow Rate
Pressure Drop P
L/min
Kgf/cm²
1
2
3
4
5
6
300
7
0
For any other viscosity, multiply by the
factors in the table right.
For any other specific gravity (G'), the
pressure drop ( P') may be obtained
from the formula below.
P' = P (G'/0.850)
DSHG-04, S-DSHG-04
DSHG-06, S-DSHG-06
DSHG-10, S-DSHG-10
Note : Figures enclosed ( ) shows curve number for shockless
type (S-DSHG-04).
379
Solenoid Controlled Pilot
Operated Directional Valves
E
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Typical Changeover Time
0
50 100 150 200 250
SOL "ON" : 3C
SOL "OFF" : 3C
Pilot Pressure
SOL "ON" : 2B
SOL "OFF" : 2B
Kgf/cm²
0 50 100 150 200 250
50
100
150
Pilot Pressure
Changeover Time
Kgf/cm²
ms
200
250
SOL "OFF" : 3C
SOL "ON" : 3C
SOL "ON" &
SOL "OFF" : 2B
2N
0 50 100 150 200 250
50
100
150
Pilot Pressure
Kgf/cm²
ms
2N
SOL "ON" : 2B
SOL "OFF" : 2B
SOL "ON" : 3C
SOL "OFF" : 3C
Changeover Time
Changeover Time
0
50
100
150
ms
Changeover time varies according to oil viscosity, spool type and hydraulic circuit.
[Test Conditions] Coil Type : D(Models with DC Solenoids)
Voltage : Rated Voltage
Oil viscosity : 35cSt
DSHG-04
DSHG-06
DSHG-10
Plug-in Connector Type: (S-) DSHG-04 - - -50
UKEN
34
101.6 50.4
204
34.9
69.8
72.9
91
1.5
50
Cylinder Port "A"
7 Dia. x Thru.
11 Dia. Spotface
2 Places
Cylinder Port "B"
Pilot Drain Port "Y"
(For External Drain Models Only)
11 Dia. x Thru.
17.5 Dia. Spotface
4 Places
Tank Port "T"
Pressure Port "P"
Pilot Pressure Port "X"
(For External Pilot Models only)
27
35
4
3 Dia.
Locating Pins
2 Places
Nut 22 Hex.
Manual Actuator
192 Max.
53.4
210
97 56.5
39
116 64 Max.
Cable Departure*
Cable Applicable:
Outside Dia. ------ 8-10mm
Conductor Area --- Not Exceeding 1.5mm²
Mounting Surface
(O-Ring Furnished)
N
N1
DIMENSIONS IN
MILLIMETRES
Mounting Surface:
ISO 4401-AD-07-4-A
Position of cable departure can
be changed. For details, refer to
DSG-01 valves on
EIC-E-1001 Page 357.
*
380
255
50.5
53.2
130.2
118 Max.
92.1
46.1
13.5 Dia. x Thru.
20 Dia. Spotface
6 Places
Pressure Port "P"
Pilot Drain Port "Y"
(For External Drain Models Only)
Cylinder Port "B"
156
77
Cylinder Port "A"
Pilot Pressure Port "X"
(For External Pilot Models Only)
13
210
97 C
56.5
D
137
Cable Departure
Cable Applicable :
Outside Dia. --- 8-10 mm
Conductor Area --- Not Exceeding 1.5 mm²
F
E
41
51.3
6
6 Dia. Two Locating Pins
Nut 22 Hex.
Manual Actuator 6 Dia.
Tank
Port
"T"
Mounting Surface
(O-Ring Furnished)
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Plug-in Connector Type : (S-)DSHG-06- - - -51
Position of cable departure can be changed. For details, refer to DSG-01 valve on EIC-E-1001 Page 357.
N
N1
DIMENSIONS IN
MILLIMETRES
Model Numbers
Dimensions mm
C
D E F
(S-)DSHG-06- -A -N/N1
39
53 202
27.5
(S-)DSHG-06- -D -N/N1
39
64 213
27.5
(S-)DSHG-06- -R -N
53
57.2
216
34
116
163
181.3
90
53.4
60
210
52
Space Needed to Remove
Solenoid-Each End
32
4
Locating Pins
2 Places
48
Manual
Actuator 6 Dia.
Nut 27 Hex.
Mounting Surface
(O-Ring Furnished)
Terminal Box Type : (S-)DSHG-04- - -50
Mounting Surface:
ISO 4401-AE-08-4-A
381
Solenoid Controlled Pilot
Operated Directional Valves
E
384
77.5 190.5
76.2
198 Max.
158.8
43
79.4
19.6
78
233.8
21.8 114.3
43
21.5 Dia. x Thru.
32 Dia. Spotface
6 Places
Tank Port "T"
Pressure Port "P"
Pilot Drain Port "Y"
(For External Drain Models Only)
Cylinder Port "B"
Cylinder Port "A"
Pilot Pressure Port "X"
(For External Pilot Model)
Cable Departure
Cable Applicable :
Outside Dia. --- 8-10 mm
Conductor Area --- Not Exceeding 1.5 mm²
F
105
97 C
56.5
D
200
E
45
6 Dia. Locating Pins
6
Mounting Surface
(O-Ring Furnished)
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Model Numbers
Dimensions mm
C
D E F
(S-)DSHG-10- -A -N/N1
39
53 265
27.5
(S-)DSHG-10- -D -N/N1
39
64 276
27.5
(S-)DSHG-10- -R -N
53
57.2
279
34
Position of cable departure can be changed. For details, refer to DSG-01 valve on EIC-E-1001 Page 357.
Terminal Box Type : (S-)DSHG-06- - -41
N
N1
DIMENSIONS IN
MILLIMETRES
90 60
210
Space Needed to Remove
Solenoid-Each End
137
184
202.3
52
Mounting surface
(O-Ring furnished)
48
Manual
Actuator 6
Nut 22
41
6
6 Dia. Locating Pins
2 Places
Electrical conduit
connection "C" Thd.
(Both Ends)
Sol
a
Sol
b
51.3
Dia. x Thru.
Plug-in Connector Type : (S-)DSHG-10- - - -41
Mounting Surface:
ISO 4401-AE-10-4-A
382
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Model Numbers
Dimension mm
E F H
J
AC SOL DC SOL R SOL
(S-)DSHG-04- -C1
145 -- 100 220 220 220
(S-)DSHG-04- -C2
145 100 -- 220 220 220
(S-)DSHG-04- -C1C2
185 140 100 260 260 260
(S-)DSHG-06- -C1
177 -- 132 252 252 252
(S-)DSHG-06- -C2
177 132 -- 252 252 252
(S-)DSHG-06- -C1C2
217 172 132 292 292 292
(S-)DSHG-10- -C1
240 -- 195 390 401 404
(S-)DSHG-10- -C2
240 195 -- 315 315 315
(S-)DSHG-10- -C1C2
280 235 195 355 355 355
OPTIONS Models with Pilot Choke valve
DIMENSIONS IN
MILLIMETRES
LOCK
LOCK
E
J
F
H
SOL a SOL b
(S-)DSHG- - -C1/C2/C1C2-
04
06
10
N
N1
28.5
Mounting surface
(O-Ring furnished)
M8 Thd.
Two Eye
Bolts
210
90 60
265.3
247
200
52
Space Needed to Remove
Solenoid-Each End
Manual
Actuator 6
Nut 22
6 Dia. Locating Pins
2 Places
Electrical conduit
connection
"C" Thd.
(Both Ends)
6 45
48
Dia. x Thru.
Terminal Box Type : (S-)DSHG-10- - -41
383
Solenoid Controlled Pilot
Operated Directional Valves
E
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
04
04X
Sub-plate
Model Numbers
C” Thd.
DHGM-04-2080 1/2 BSP.F
DHGM-04X-2080 3/4 BSP.F
Valve Types Pilot Pressure Port “X” Port “Y” Remarks
Solenoid Controlled Pilot
Operated Directional Valves
Used only on external pilot type
valves.
To be plugged on internal pilot type
Valves.
Used as drain port only on external
drain type valves.
To be plugged on internal pilot type
Valves.
Pilot
Operated
Directional
Valves
Spring Centered
No-Spring
Used
Used as pilot port
Normal size:
Only 04
Spring offset Used as pilot drain port
Manually Operated Direction Valves Not used (plug is not required) Used as drain port
Model Numbers C D E
(S-)DSHG-04- -R2
288 94 33
(S-)DSHG-06- -R2
376 111 40
(S-)DSHG-10- -R2
558 164.5 65
OPTIONS Models with Stroke Adjustment
Stroke Adj. Screw (Port "A" End )
13 Hex.
Fully Extended D
E
Lock Nut 17 Hex.
Stroke Adjustment Screw (Port "B" End )
13 Hex.
Fully Extended C
SOL a
SOL b
(S-)DSHG- - -R
04
06
10
Sub Plate DHGM- -2080
DIMENSIONS IN
MILLIMETRES
384
T
P
X
A
B
Y
20
36
166
101.6
190
32.2
76.7
34
18.3
120
96
69.8
55.6
14.2
1.6
12
12
71.4 13.1
10.1
16
57.1
90
88.1
65.814.2
11 Dia. x Thru.
17.5 Dia. Spotface
4 Places
3.6 Dia. x 5 Deep
2 Places
130
6 Dia. 2 Places
17.5 Dia.
4 Places
M6 Thd. x 15 Deep
2 Places
29
65
137.5
102
58
21.5
33
76
125
90
46
T
P
X
A
B
Y
1
4
BSP.F Thd.
2 Places
"C" Thd.
4 Places
M10 Thd. x 21 Deep
4 Places
50
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
DHGM- -4080
10
10X
Sub-plate Model
Numbers
C” Thd.
Dimensions mm
F H J K
DHGM-10-4080 1-1/4 BSP.F 152 79 185.5 120.5
DHGM-10X-4080 1-1/2 BSP.F 156 74 194.5 112.5
W
Y
B
A
P
T
V
X
W
Y
P
T
B
A
X
V
50
35
12
130.225
204
180
8.9
12
110
134
92.1
M12 Thd. x 24 Deep
6 Places
11.9
116
11 Dia.
4 Places
24.5 Dia.
4 Places
J
H
F
E
12.5
156
17.5
73.1
N
L
K
19.1
46.1
74.6
D
1/4 BSP.F Thd.
4 Places
"C" Thd.
4 Places
7 Dia. x 8 Deep
2 Places
DHGM- -5080
06
06X
Sub-plate
Model Numbers
C” Thd.
Dimensions mm
D E F H J K L N
DHGM-06-5080 ¾ BSP.F 151.2 137.7 102 54.4 30.6 125.8 78.2 42.5
DHGM-06X-5080 1 BSP.F 155.2 148 106 50 25 130 74 32
For uses of Port “X”, “Y”, “V”, “W”, refer to DHGM-10-
DIMENSIONS IN
MILLIMETRES
385
Solenoid Controlled Pilot
Operated Directional Valves
E
306.5
266.520
190.5
38
168.3
147.6
114.3
76.2
41.3
199
158.8
79.4
123.8
20.1
28.6
114.3
35
60
45
234
82.521.8
7 Dia. x 8 Deep
2 Places
M20 Thd. x 34 Deep
6 Places
17.5 Dia. x Thru.
26 Dia. Spotface
4 Places
36 Dia.
4 Places
213
F
H
J
55
K
3/8 BSP.F Thd.
4 Places
11 Dia.
4 Places
Y
P
T
V
W
B
A
X
"C" Thd.
4 Places
W
Y
B
A
P
T
V
X
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
Valve Types Pilot Pres. Port “X”
Port Y” Port “V” Port W”
Solenoid
Controlled
Pilot
Operated
Directional
Valves
Spring centered, No-spring,
Spring offset
Used only on
external pilot type
valves.
To be plugged on
internal pilot type
valves.
Used as drain port only
on external drain type
valves.
To be plugged on *
internal pilot type
valves.
Not used (plug is not required)
Pilot
Operated
Directional
Valves
Spring centered, No-spring,
Used
Used as pilot pres. Port
Not used (plug is not required)
Spring offset Used pilot port drain port
Manually Operated Directional Valves
Not used
(plug is not required)
Not used
(plug is not required)
Used
Not used (plug
is
not required)
Note : Uses of port “X”, “Y”, “V” and “W
* As the thread is provided on the body, plug either port on the sub-plate or port on the body.
Conversion of Internal Pilot/Drain :
P
T
Removed For
Internal Pilot
Models
DSHG-04- - - - - - -46
1/16-27 NPT
A
B
P
T
P
T
Removed For Internal Pilot Models
1/16-27 NPT
DSHG-04- - - - - - -50
Removed for
Internal
Drain Models
Comparison of DSHG-04-46 and DSHG-04-50 for Internal Pilot Models.
Removed for
Internal
Pilot Models
Removed for
External
Drain Models
Removed for
Internal
Drain Models
(S-)DSHG-06- - -51
(S-)DSHG-10- - -41
386
Spare Parts List
List of Seals
Sl.
No.
Part Numbers
Name of Part DSHG-04 DSHG-06 DSHG-10 Qty
1 O-Ring SO-NB-P9 -- -- 4
2 O-Ring -- SO-NB-P9 -- 2
3 O-Ring -- SO-NB-P14 2
4 O-Ring -- -- SO-NB-P20 2
5 O-Ring -- SO-NB-P30 -- 4
6 O-Ring SO-NB-P34 -- -- 2
7 O-Ring -- SO-NB-P40 -- 2
8 O-Ring -- -- SO-NB-P42 4
9 O-Ring -- -- SO-NB-G65 2
10 O-Ring SO-NB-P22A -- -- 4
List of Seal kits
Note: When ordering the seals, please specify the Seal Kit number from the table below.
Valve Model Numbers Seal Kit Numbers
DSHG-04 KS-DSHG-04-50
DSHG-06 KS-DSHG-06-51
DSHG-10 KS-DSHG-10-41
Note: When ordering the seals, please specify the Seal Kit number KS-DSHG-04-50/KS-DSHG-06-51/ KS-DSHG-10-41.
List of Pilot Valves
Valve Model Numbers Pilot Valve Model Numbers
(S-)DSHG-04/06/10-3C - - DSG-01-3C4- --50
(S-)DSHG-04-2B - - DSG-01-2B2- --50
(S-)DSHG-06/10-2B - - DSG-01-2B2- --50-L
(S-)DSHG-04/06/10-2N - - DSG-01-2D2- --50
Notes:
1 Fill coil type (a symbol representing current/
voltage) in section marked Likewise, in
selection marked ▲,
fill a symbol representing the type of conduit
connection (N: Plug-in connector type).
2 For the details of the pilot valves, see page
EIC-E-1001 Page: 349.
Solenoid Controlled Pilot Operated Directional Valves
DIRECTIONAL CONTROLS
387
Solenoid Controlled Pilot
Operated Directional Valves
E