HC-Type Pressure control Valves
■ Instructions
To adjust the pressure, loosen the lock nut and turn the pressure adjustment screw slowly clockwise to increase
pressure or anti-clockwise to decrease pressures. After adjustments, do not forget to tighten the lock nut.
Connect the secondary side primary pressure ports of types 1 and 4 (internal drain) and the drain ports of types 2 and
3 (external drain) directly to the tanks with a back pressure close to the atmospheric pressure.
There are two threaded connection primary pressure ports with HCT type. They can be connected each other in-line;
one as inlet and the other as an outlet or the valve can be used by plugging one of the pressure ports.
■ Attachment
Mounting Bolts
Valve Model
Numbers
Socket Head Cap Screw Qty.
Bolt Kit
Ordering Code
HCG-06 M10 x 80Lg. 4 BKHCG-06-20
HCG-10 M10 x 90Lg. 6 BKHCG-10-20
■ Sub-plate
Valve
Model Numbers
Sub-Plate
Model Numbers
Thread
Size
Mass
Kg.
HCG-06-
HGM-06-2080 3/4 BSP.F 2.4
HGM-06X-2080 1 BSP.F 3.0
HCG-06- -P
HGM-06-P-2080 3/4 BSP.F 2.4
HGM-06X-P-2080 1 BSP.F 3.0
HCG-10-
HGM-10-2080 1-1/4 BSP.F 4.8
HGM-10X-2080 1-1/2 BSP.F 5.7
HCG-10- -P
HGM-10-P-2080 1-1/4 BSP.F 4.8
HGM-10X-P-2080 1-1/2 BSP.F 5.7
Sub-Plate are available. Specify the sub-plate model from the table above. When sub-plate
are not used, the mounting surface should have a good machined finish.
* Sub-Plates are same as applicable to HG-10- - -10 valves. For dimensions refer page no. 287.
Valve Type
Type 1:
Counterbalance Valve
Type 2:
Sequence and Check Valve
Type 3:
Sequence and Check Valve
Type 4:
Counterbalance Valve
Pilot-Drain Type
Internal Pilot-Internal
Drain
Internal Pilot-External
Drain
External Pilot-External
Drain
External Pilot-Internal
Drain
Operations
Graphic Symbols
Description
Used to prevent gravitational
falls by generating a pressure
on the actuator return side. If
Primary pressure exceeds the
pressure setting, fluid is
released to keep the pressure
constant.
Used to control the operating
sequence of two or more
actuators. If primary pressure
exceeds the pressure setting
effective fluid is delivered to the
secondary side. Reversed flow is
free by check valve.
Used for same purpose as for type
2. Operated by external
pilot pressure irrespective
of primary pressure.
Reversed flow is free by
check valve.
Used for the same purpose
as for type 1. Operated by
External pilot pressure
irrespective of primary pressure.
Reversed flow is free by check
valve.
1
8
With auxiliary pilot port
1
8
With auxiliary pilot port
1
8
With auxiliary pilot port
1
8
With auxiliary pilot port
■ Valve Types
HC Type
PRESSURE CONTROLS
HC-Type Pressure
Control Valves
289
C