PRESSURE CONTROLS
H-Type Pressure control Valves
H Type Pressure Control Valves
These valves are hydraulically damped, direct operated, pressure control
valves which can be actuated by internal or external pilot pressure. There
are various types of valve including sequence, unloading and low
pressure relief valves, all of which are operated by a pressure rise in the
circuit, sensed either internally or remotely.
Specifications
Model Number Designation
Model Numbers
Max.
Operating
Pressure
Kgf/cm
2
Max.
Flow
L/min.
Mass
Kg.
Threaded
Connection
Sub-Plate
Mounting
Threaded
Connection
Sub-Plate
Mounting
HT-03- - -2280
210
50 3.7 4
HT-06- - -2280
125 6.2 6.1
HT-10- - -2280 HG-10- - -10
250 12 11
*1 For details of valve types, see the following page.
*2 Consult YUKEN for availability.
*3 Type 1 is only possible for pressure adjustment ranges L and M.
*4 Model with auxiliary pilots are used where valves must be operated under a lower external pilot pressure than the
adjusted pressure (types N, A and B about 1/8 of adjusted pressure; type C: about 1/16). This does not apply to
pressure adjustment ranges L and M, and valve type 1.
EIC-C-1003-0
283
H-Type Pressure
Control Valves
C
F- H T -10 -C 3 -P -22
Special
Seals
Series
Number
Type of
Mounting
Valve
Size
Pres. Adj.
Range
Kgf/cm
2
Valve
Type
*1
With
Auxiliary
Pilot
Pressure
Design
Number
Design
Standard
F:
Special
Seals for
Phosphate
Ester Type
Fluids.
(Omit if not
required)
H:
H Type
Pressure
Control
Valves
T:
*2
Threaded
Connection
03
L: 2.5~4.5
M: 4.5~9
N: 9~18
A: 18~35
B: 35~70
C: 70~140
1
*3
2
3
4
P:
*4
With
Auxiliary
Pilot
Pressure
22 80
06
10
G:
Sub-plate
Mounting
10 10
H-Type Pressure control Valves
Instructions
To adjust the pressure, loosen the lock nut and turn the pressure adjustment screw slowly clockwise to increase
pressure or anti-clockwise to decrease pressure. After adjustments, do not forget to tighten the lock nut.
Connect the secondary side pressure ports of types 1 and 4 (internal drain) and the drain ports of types 2 and
3 (external drain) directly to the tanks with a back pressure close to the atmospheric pressure.
There are two threaded connection primary pressure ports. They can be connected each other in-line; one
as inlet and the other as an outlet or the valve can be used by plugging one of the pressure ports.
Attachment
Mounting Bolts
Valve Model
Number
Socket Head Cap Screw Qty.
Bolt Kit
Number
HG-10 M10 x 50Lg. 6 BKHG-10-10
Sub-plate
Valve
Model Numbers
Sub-Plate
Model Numbers
Thread
Size
Mass
Kg.
HG-10-
HGM-10-2080 1-1/4 BSP.F 4.8
HGM-10X-2080 1-1/2 BSP.F 5.7
HG-10- -P
HGM-10-P-2080 1-1/4 BSP.F 4.8
HGM-10X-P-2080 1-1/2 BSP.F 5.7
Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.
With auxiliary
pilot port
1
8
Valve Types
Valve Type
Type 1:
Low Pres. Relief Valve
Type 2:
Sequence Valve
Type 3:
Sequence Valve
Type 4:
Unloading Valve
Pilot-Drain Type
Internal Pilot-Internal
Drain
Internal Pilot-External
Drain
External Pilot-External
Drain
External Pilot-Internal
Drain
Operations
Graphic Symbols
Description
Can be used as low-
pressure relief valve, but
be careful to occurrence of
surge pressure.
Used to control the
operational sequence of 2
or more actuators. If
primary pressure exceeds
the pressure setting,
effective fluid is delivered
to the secondary side.
Used for the same
purpose as for the type 2.
Operated by external pilot
pressure irrespective of
primary pressure.
Used as unloading valve.
If external pilot pressure
exceeds the pressure
setting, the pump is turned
no-load by releasing all
fluid to the tank.
H Type
With auxiliary
pilot port
1
8
With auxiliary
pilot port
1
8
PRESSURE CONTROLS
284
H-Type Pressure control Valves
Type 1:Low Pressure Relief Valve
(Internal Pilot, Internal Drain)
Type 2: Sequence Valve
(Internal Pilot, External Drain)
Type 4: Unloading Valve
(External Pilot, Internal Drain)
Type 3: Sequence
(External Pilot, External Drain)
DIMENSIONS IN
MILLIMETRES
HT-03,06,10- - -2280
PRESSURE CONTROLS
285
H-Type Pressure Control
Valve
Model
Numbers
Thread Size
“Q” Thd. “S” Thd. “T” Thd.
HT-03 3/8 BSP.F
1/4
BSP.F
1/4
BSP.Tr
HT-06 3/4 BSP.F
HT-10 1-1/4 BSP.F
Model
Numbers
Dimensions mm
A B C D E F J K L N V
HT-03 41 82 60 74 191 57 43 70 0 28 28
HT-06 48 96 73 87 221 64.5 50.5 80.5 9 33 42
HT-10 66 132 86 112 272 84 66 98 12 40 52
A
D
A
B
"C" SQ.
Fully Extended E
Lock Nut
13 Hex.
Secondary Pressure
Outlet Port
"Q" Thd.
Primary Pressure
Gauge Connection
"T" Thd.
External Pilot
Port "X"
"S" Thd.
Drain Port
"S" Thd.
Secondary Pressure
Gauge Connection
"T" Thd.
V
Aux.Pilot Port "Y"
"S" Thd.
(For "P" Models Only)
Pressure Adj. Screw
10 Hex.
Primary Pressure
Inlet Port
"Q" Thd.
2 Places
J N
KF
L
Inc.
Plug
Plug
Plug
Drain
Port
Plug
External Pilot
Port
C
H-Type Pressure control Valves
119
62
Fully Extended 272
Auxiliary Pilot Port "Y"
(For "P" models Only)
Primary Pressure
Inlet Port
External Pilot Port
"X"
11 Dia. x Thru.
17.5 Dia. Spotface
6 Places
Secondary Pressure
Outlet Port
Lock Nut 13 Hex.
Pressure Adjustment Screw
10 Hex.
39
46
92
86 Sq.
6
Locating Pin
6 dia.
Mounting
Surface
(O-Ring
Furnished)
Drain Port
Inc.
Type 1:Low Pressure Relief Valve
(Internal Pilot, Internal Drain)
Type 2: Sequence Valve
(Internal Pilot, External Drain)
Type 4: Unloading Valve
(External Pilot, Internal Drain)
Drain
Port
External
Pilot
Port
Type 3: Sequence
(External Pilot, External Drain)
DIMENSIONS IN
MILLIMETRES
Mounting Surface
ISO 5781-AJ-10-2-A
HG-10- - -10
PRESSURE CONTROLS
286
E
116
F
12
22
43
104
126
177
25.5
16.7
24.6
42.1
59.5
62.7
67.5
84.1
21
120
96.8
92.9
48.4
4
15
9.6
11.6
1675
20
50
"A" Thd. 2 Places
28 Dia. 2 Places
7 Dia. x 10 Deep
For Locating Pin
"B" Thd. 2 Places
5 Dia. 2 Places
"C" Thd. x 20 Deep
6 Places
11 Dia. x Thru.
17.5 Dia. Spotface
4 Places
"D" Thd.
5 Dia.
"HGM-10X-P"
Auxiliary Pilot Pressure
Models Only
19
140
DIMENSIONS IN
MILLIMETRES
Sub-Plate
Model Numbers
“A” Thd. “B” Thd. “C” Thd. “D” Thd.
“E”
HGM-10-2080
1-1/4
BSP.F
1/4
BSP.F
M10
1/4
BSP.F
13.6
HGM-10-P-2080 9.6
Sub-Plate
Model Numbers
“A” Thd. “B” Thd. “C” Thd. “D” Thd.
E F
HGM-10X-2080
1-1/2
BSP.F
1/4
BSP.F
M10
1/4
BSP.F
13.6 102.5
HGM-10X-P-2080 9.6 106
12
"E"
116
140
30
43
96
126
150
4
15
92.9
48.4
96.8
120
11.6
9.6
16.7
24.6
42.1
59.5
62.7
67.5
84.1
135
45
20
7.5
5 Dia. 2 Places
"C" Thd. x 20 Deep
6 Places
11 Dia. x Thru.
17.5 Dia. Spotface
4 Places
7 Dia. x 10 Deep
For Locating Pin
28 Dia. 2 Places
"A" Thd. 2 Places
"B" Thd.
2 Places
"D" Thd.
5 Dia.
"HGM-10-P"
Auxiliary Pilot
Pressure
Models Only
19
12
HGM-10-2080
HGM-10-P-2080
HGM-10X-2080
HGM-10X-P-2080
PRESSURE CONTROLS
H-Type Pressure Control
Valve
H-Type Pressure control Valves
287
C
HC-Type Pressure control Valves
HC Type Pressure Control Valves
These valves are hydraulically damped, direct
operated, pressure control valves which can be
actuated by internal or external pilot pressure.
They are available with integral check valves for
use when reverse free flow from the secondary
port to the primary port is desired. There are
various types of valve including sequence
counterbalance valves, all of which are operated
by a pressure rise in the circuit, sensed either
internally or remotely.
Specifications
Model Number Designation
*1 For details of valves types, see the following page.
*2 Consult YUKEN for availability.
*3 Type 1 is only possible for pressure adjustment ranges L and M.
*4 Models with auxiliary pilot are used where valves must be operated under a lower external pilot pressure than the
adjusted pressure (types N, A and B: about 1/8 of adjusted pressure; type C: about 1/16). This does not apply to
pressure adjustment ranges L and M, and valve type 1.
For Check Valve pressure drops, see free flow pressure drop characteristics.
Model Numbers
Max.
Operating
Pressure
Kgf/cm
2
Max.
Flow
L/min.
Mass (Approx.)
Kg.
Threaded
Connection
Sub-Plate
Mounting
Threaded
Connection
Sub-Plate
Mounting
HCT-03- - 2280
210
50 4.1 4.8
HCT-06- - 2180 HCG-06- - - -21
125 7.1 7.4
HCT-10- - 2280 HCG-10- - - -21
250 13.8 13.8
PRESSURE CONTROLS
288
F- HC T -03 -C 3 -P -21
Special
Seals
Series
Number
Type of
Mounting
Valve
Size
Pres. Adj.
Range
Kgf/cm
2
Valve
Type
*1
With
Auxiliary
Pilot Pressure
Design
Number
Design
Standards
F:
Special
Seals for
Phosphate
Ester Type
Fluids.
(Omit if not
required)
HC:
HC Type
Pressure
Control
Valves
T:
*2
Threaded
Connection
03
L: 2.5~4.5
M: 4.5~9
N: 9~18
A: 18~35
B: 35~70
C: 70~140
1
*3
2
3
4
P:
*4
With
Auxiliary
Pilot
Pressure
22
80
06 21
10 22
G:
Sub-plate
Mounting
06 21
10 21
HC-Type Pressure control Valves
Instructions
To adjust the pressure, loosen the lock nut and turn the pressure adjustment screw slowly clockwise to increase
pressure or anti-clockwise to decrease pressures. After adjustments, do not forget to tighten the lock nut.
Connect the secondary side primary pressure ports of types 1 and 4 (internal drain) and the drain ports of types 2 and
3 (external drain) directly to the tanks with a back pressure close to the atmospheric pressure.
There are two threaded connection primary pressure ports with HCT type. They can be connected each other in-line;
one as inlet and the other as an outlet or the valve can be used by plugging one of the pressure ports.
Attachment
Mounting Bolts
Valve Model
Numbers
Socket Head Cap Screw Qty.
Bolt Kit
Ordering Code
HCG-06 M10 x 80Lg. 4 BKHCG-06-20
HCG-10 M10 x 90Lg. 6 BKHCG-10-20
Sub-plate
Valve
Model Numbers
Sub-Plate
Model Numbers
Thread
Size
Mass
Kg.
HCG-06-
HGM-06-2080 3/4 BSP.F 2.4
HGM-06X-2080 1 BSP.F 3.0
HCG-06- -P
HGM-06-P-2080 3/4 BSP.F 2.4
HGM-06X-P-2080 1 BSP.F 3.0
HCG-10-
HGM-10-2080 1-1/4 BSP.F 4.8
HGM-10X-2080 1-1/2 BSP.F 5.7
HCG-10- -P
HGM-10-P-2080 1-1/4 BSP.F 4.8
HGM-10X-P-2080 1-1/2 BSP.F 5.7
Sub-Plate are available. Specify the sub-plate model from the table above. When sub-plate
are not used, the mounting surface should have a good machined finish.
* Sub-Plates are same as applicable to HG-10- - -10 valves. For dimensions refer page no. 287.
Valve Type
Type 1:
Counterbalance Valve
Type 2:
Sequence and Check Valve
Type 3:
Sequence and Check Valve
Type 4:
Counterbalance Valve
Pilot-Drain Type
Internal Pilot-Internal
Drain
Internal Pilot-External
Drain
External Pilot-External
Drain
External Pilot-Internal
Drain
Operations
Graphic Symbols
Description
Used to prevent gravitational
falls by generating a pressure
on the actuator return side. If
Primary pressure exceeds the
pressure setting, fluid is
released to keep the pressure
constant.
Used to control the operating
sequence of two or more
actuators. If primary pressure
exceeds the pressure setting
effective fluid is delivered to the
secondary side. Reversed flow is
free by check valve.
Used for same purpose as for type
2. Operated by external
pilot pressure irrespective
of primary pressure.
Reversed flow is free by
check valve.
Used for the same purpose
as for type 1. Operated by
External pilot pressure
irrespective of primary pressure.
Reversed flow is free by check
valve.
1
8
With auxiliary pilot port
1
8
With auxiliary pilot port
1
8
With auxiliary pilot port
1
8
With auxiliary pilot port
Valve Types
HC Type
PRESSURE CONTROLS
HC-Type Pressure
Control Valves
289
C
Type 1: Counterbalance Valve
(Internal Pilot, Internal Drain)
Type 2: Sequence and Check Valve
(Internal Pilot, External Drain)
Type 4: Counterbalance Valve
(External Pilot, Internal Drain)
Type 3: Sequence and Check Valve
(External Pilot, External Drain)
DIMENSIONS IN
MILLIMETRES
HC-Type Pressure Control Valves
HCT-03,10- - -2280
PRESSURE CONTROLS
Plug
Plug Plug
Drain
Port
Plug
External
Pilot Port
A
D
A
B
"C" SQ.
K
"E" Fully Extended
External Pilot Port
"S" Thd.
Primary Pressure
Gauge Connection
"T" Thd.
Secondary Pressure Outlet Port
or Reversed Free Flow Inlet Port
"Q" Thd.
Pressure Adj. Screw
10 Hex.
V
Drain Port
"S" Thd.
Secondary Pressure
Gauge Connection
"T" Thd.
Primary Pressure Inlet Port or
Reversed Free Flow Outlet Port
"Q" Thd.
2 Places
Auxiliary Pilot Port "Y"
"S" Thd.
(For "P" Models Only)
Lock Nut
13 Hex.
Inc.
F
NJ
L
Model
Numbers
Dimensions mm
A B C D E F J K L N V
HCT-03 41 82 60 96 191 57 43 70 0 28 28
HCT-10 66 132 86 152 272 84 66 98 12 40 52
Model
Numbers
Thread Size
“Q” Thd. “S” Thd. “T” Thd.
HCT-03 3/8 BSP.F
1/4
BSP.F
1/4
BSP.Tr
HCT-10 1-1/4 BSP.F
290
48
116
48
96
73 Sq.
339
80.550.5
64.5 123.5
Fully Extended 221
65
60
External Pilot "X"
Port
1
4
BSP.F Thd.
Primary Pressure Gauge
Connection
1
4
BSP.Tr Thd.
Secondary Outlet Port
or Reversed Free Flow
Inlet Port
3
4
BSP.F Thd.
Pressure Adjustment Screw
42
Drain Port
1
4
BSP.F Thd.
Secondary Pressure Gauge
Connection
1
4
BSP.Tr Thd.
Primary Pressure Inlet Port or
Reversed Free Flow Outlet Port
3
4
BSP.F Thd. 2 Places
"Y"
Auxiliary Pilot Pressure Port
1
4
BSP.F Thd. For "P" Model
Only
Lock Nut
13 Hex.
Inc.
Type 1: Counterbalance Valve
(Internal Pilot, Internal Drain)
Type 2: Sequence and Check Valve
(Internal Pilot, External Drain)
Type 4: Counterbalance Valve
(External Pilot, Internal Drain)
Type 3: Sequence and Check Valve
(External Pilot, External Drain)
DIMENSIONS IN
MILLIMETRES
Plug in
Place
Plug in
Place
Plug in
Place
Drain
Port
Plug in
Place
External
Pilot Port
HCT-06- - -2180
PRESSURE CONTROLS
291
HC-Type Pressure
Control Valves
C
HC-Type Pressure control Valves
HCG-06- - -21
HC-Type Pressure control Valves
24
6
Locating Pin
6 Dia.
108
69
40
73 Sq.
102
41
51
19
188
Fully Extended 221
Mounting
Surface
(O-Ring
Furnished)
Lock Nut 13 Hex.
Primary Pressure Inlet Port
or Reversed Free Flow
Outlet Port
External Pilot
Pressure Port "X"
11 Dia. x Thru.
17.5 Dia. Spotface
4 Places
Secondary Pressure Outlet Port or
Reversed free Flow Inlet Port
Auxiliary Pilot Port
(For "P" models only)
Drain Port
Secondary Pressure
Gauge Connection
1
4
BSP.Tr thd.
Primary Pressure
Gauge Connection
1
4
BSP.Tr Thd.
Pressure Adj. Screw
Inc.
Drain
Port
Type 3: Sequence and Check Valve
(External Pilot, External Drain)
DIMENSIONS IN
MILLIMETRES
Type 1: Counterbalance Valve
(Internal Pilot, Internal Drain)
Type 2: Sequence and Check Valve
(Internal Pilot, External Drain)
Type 4: Counterbalance Valve
(External Pilot, Internal Drain)
PRESSURE CONTROLS
Mounting Surface
HCG-06: ISO 5781-AH-08-2-A
292
External
Pilot Port
HC-Type Pressure control Valves
Type 3: Sequence and Check Valve
(External Pilot, External Drain)
DIMENSIONS IN
MILLIMETRES
Mounting Surface
ISO 5781-AJ-10-2-A
Drain
Port
External
Pilot Port
Type 1: Counterbalance Valve
(Internal Pilot, Internal Drain)
Type 2: Sequence and Check Valve
(Internal Pilot, External Drain)
Type 4: Counterbalance Valve
(External Pilot, Internal Drain)
78
Lock Nut
13 Hex.
6
Locating Pin
6 Dia.
Mounting
Surface
(O-Ring
Furnished)
119
62
Fully Extended 272
Drain Port
Auxiliary Pilot Port
(For "P" models only)
Primary Pressure Inlet Port
or Reversed Free Flow
Outlet Port
External Pilot
Pressure Port "X"
11 Dia. x Thru.
17.5 Dia. Spotface
6 Places
Secondary Pressure Outlet Port or
Reversed free Flow Inlet Port
46
79
132
86 Sq.
Pressure Adjustment Screw
10Hex.
Inc.
HCG-10- - -21
PRESSURE CONTROLS
293
HC-Type Pressure
Control Valves
C
HC-Type Pressure control Valves
6.4
14
39.7
73
79.4
11.1
20.6
44.5
49.2
60.3
93
22
16.5
D
F
E
C
104
A
B
H
G
102
39.7
22 Dia. 2 Places
M10 Thd. x 20 Deep
4 Places
5 Dia. 2 Places
1
4
BSP.F Thd.
5 Dia.
"P" Models Only
7 Dia. x 10 Deep
8.8 Dia. x Thru.
14 Dia. Spotface
4 places
1
4
BSP.F Thd.
2 Places
3
4
or 1 BSP.F Thd.
2 Places
J
16
DIMENSIONS IN
MILLIMETRES
06
06X
Sub Plate
Model Numbers
Thread
Size
BSP.F
A B C D E F G H J
Mass
(Approx.)
Kg.
Recommended
Max. Flow
Capacity L/min.
HGM-06-2080 3/4 124 10 77 27 61.7
39
73 6.4 36 2.4 80
HGM-06X-2080 1 136 16 80 22 61.7 75 6.4 45 3 125
HGM-06-P-2080 3/4 124 10 77 27 64 73 3 36 2.4 80
HGM-06X-P-2080 1 136 16 82.3 22 64 75 3 45 3 125
Sub-Plate : HGM - - -2080
PRESSURE CONTROLS
294
HC-Type Pressure control Valves
6
5
3
1
0
L/min.
200150100500
4
2
250
Flow Rate
Kgf/cm²
Pressure Drop P
Pressure Drop for Reversed Free Flow
For any other viscosity, multiply the factors in the table below.
For any other specific gravity (G), the pressure drop ( P`)
may be obtained from the formula below.
P` = P (G`/0.850)
PRESSURE CONTROLS
4
3
2
1
0
L/min.
1007550250
Flow Rate
Kgf/cm²
Pressure Drop P
125
Hydraulic Fluid: Viscosity: 35 cSt. Specific Gravity: 0.850
HCT-06
HCG-06
4
3
2
1
L/min.
403020100
Flow Rate
Kgf/cm²
Pressure Drop P
50
HCT-03
HCT-10
HCG-10
295
HC-Type Pressure
Control Valves
Viscosity
cSt
15
20
30
40
50
60
70
80
90
100
Factor 0.81
0.87
0.96
1.03
1.09
1.14
1.19
1.23
1.27
1.30
C
HC-Type Pressure control Valves
Nominal Override Characteristics
PRESSURE CONTROLS
Hydraulic Fluid: Viscosity: 35 cSt. Specific Gravity: 0.850
296
50 100 150 200 250
2.5
3.5
4.5
6
7
8
9
10
15
20
20
25
30
35
50
60
70
100
120
140
10 20 30 40 25 50 75 100 12550
2.5
3.5
4.5
6
7
8
9
10
15
20
20
25
30
35
50
60
70
100
120
140
40
0
0 0
2.5
3.5
4.5
6
7
8
9
10
15
20
20
25
30
35
50
60
70
100
120
140
L/min.
L/min.
L/min.
Kgf/cm²
Kgf/cm²
Kgf/cm²
Secondary Pressure
Secondary Pressure
Secondary Pressure
HT / HCT-03-C
HT / HCT-03-B
HT / HCT-03-A
HT / HCT-03-N
HT / HCT-03-M
HT / HCT-03-L
H / HC -10-C
H / HC -10-B
H / HC -10-A
H / HC -10-N
H / HC -10-M
H / HC -10-L
HT / HC -06-C
HT / HC -06-B
HT / HC -06-A
HT / HC -06-N
HT / HC -06-M
HT / HC -06-L
Flow Rate Flow Rate
Flow Rate
HC-Type Pressure control Valves
Spare Parts List
List of Seals
List of Seal Kits
Model
Numbers
Seal kit
Numbers
HT-03 KS-HT-03-22
HT-06 KS-HT-06-22
HT-10 KS-HT-10-22
HG-10-P KS-HG-10-P-22
HG-10 KS-HG-10-10
Note: When ordering the seals, Please specify the seal kit numbers from the table right.
PRESSURE CONTROLS
Sl.
No.
Name of
Parts
Part Number Quantity
HT-03 HT-06
HT-10
HG-10
HT- HG-
1 O – Ring SO-NB-P4 SO-NB-P4 SO-NB-P4
3*
2 O – Ring SO-NB-P6 SO-NB-P6 SO-NB-P6 4 4
3 O – Ring SO-NB-P9 SO-NB-P9 SO-NB-P9
1*
4 O – Ring SO-NB-P9 SO-NB-P9 SO-NB-P9
2
5 O – Ring SO-NA-P11 SO-NA-P15 SO-NA-P20 1 1
6 O – Ring SO-NB-P18 SO-NB-P28 SO-NB-P32
2
7 O – Ring SO-NB-P22 SO-NB-P28 SO-NB-P36 2 2
8
Bonded
Seal
SG-FB-1/4 SG-FB-1/4 SG-FB-1/4 2
297
HC-Type Pressure
Control Valves
HT-03,06,10- - -2280
HG-10- - -10
HCT-03,06,10- - -2280
HCG-06- - -2180
HCG-06,10- - -21
* Used only for HG type with auxiliary pilot pressure (P).
Model
Numbers
Seal kit
Numbers
HCT-03 KS-HCT-03-22
HCT-06 KS-HCT-06-21
HCT-10 KS-HCT-10-22
HCG-06-P KS-HCG-06-P-21
HCG-06 KS-HCG-06-21
HCG-10-P KS-HCG-10-P-21
HCG-10 KS-HCG-10-21
Sl.
No.
Name of
Parts
Part Number Quantity
HCT-03
HCT-06
HCG-06
HCT-10
HCG-10
HCT- HCG-
1 O – Ring SO-NB-P4 SO-NB-P4 SO-NB-P4
3*
2 O – Ring SO-NB-P6 SO-NB-P6 SO-NB-P6 4 4
3 O – Ring SO-NB-P9 SO-NB-P9 SO-NB-P9
1*
4 O – Ring SO-NB-P9 SO-NB-P9 SO-NB-P9
2
5 O – Ring SO-NA-P11 SO-NA-P15 SO-NA-P20 1 1
6 O – Ring SO-NB-P12 SO-NB-P18 SO-NB-P22A 1 1
7 O – Ring SO-NB-P18 SO-NB-P28 SO-NB-P32
2
8 O – Ring SO-NB-P22 SO-NB-P28 SO-NB-P36 2 2
9
Bonded
Seal
SG-FB-1/4 SG-FB-1/4 SG-FB-1/4 2
Note: When ordering the seals, Please specify the seal kit numbers from the table right.
* Used only for HG type with auxiliary pilot pressure (P).
List of Seal KitsList of Seals