F:
Special Seals
for Phosphate
Ester Type
Fluids.
(Omit if not
required)
YB:
Direct
Type
Relief
Valves
F:
Flange
Mounting
(Omit if not
Required)
A: 3 ~ 40
B: * ~ 70
C: 35 ~ 140
D: * ~ 160
E: 2 ~ 10
Direct Type Relief Valves
■ Direct Type Relief Valves
This valve is used in hydraulic system to prevent damage due
to over pressure and to adjust the maximum system pressure
of small capacity.
■ Specifications
■ Model Number Designation
■ Instructions
To adjust the pressure, loosen the lock nut and slowly turn the handle clockwise
for higher pressure or anti-clockwise for lower pressures. After adjustments,
do not forget to tighten the lock nut.
Piping of the tank line should not be connected to any tank line of the other
valves, but connected directly to the tank.
■ Attachment
■ Sub-plate
Max. Operating
Pressure
Kgf/cm
2
Note: Refer to the Model Number Designation.
* Refer to the Minimum Adjustment Pressure Characteristics.
Sub-plates are available, specify sub-plate model number from the table above.
When sub-plates are not used the mounting surface should have a good machined finish.
PRESSURE CONTROLS
Mounting Bolts
Graphic Symbol
Direct Type Relief Valves
255