FLOW
CONTROLS
Sub-plate / Instructions
D
2.3 (5.1)
2.3 (5.1)
3.1 (6.8)
3.9 (8.6)
3.9 (8.6)
5.7 (12.6)
5.7 (12.6)
12.5 (27.6)
16 (35.3)
16 (35.3)
Valve
Model
Numbers
-01
FG
FCG
-02
FG
FCG
-03
FG
FCG
-06
FG
FCG
-10
FG
FCG
Japanese Standard "JIS"
Sub-plate
Model No.
Thread
Size
European Design Std.
Sub-plate
Model No.
Sub-plate
Model No.
N. American Design Std.
Approx.
Mass
kg (lbs.)
FGM-01X-10
FGM-02-20
FGM-02X-20
FGM-02Y-20
FGM-03-20
FGM-03X-20
FGM-03Y-20
FGM-03Z-20
FGM-06X-20
FGM-06Y-20
FGM-06Z-20
FGM-10Y-20
Rc 1/4
Rc 1/4
Rc 3/8
Rc 1/2
Rc 3/8
Rc 1/2
Rc 3/4
Rc 1
Rc 1
Rc 1-1/4
Rc 1-1/2
1-1/2, 2
FGM-01X-1080
FGM-02-2080
FGM-02X-2080
FGM-02Y-2080
FGM-03-2080
FGM-03X-2080
FGM-03Y-2080
FGM-03Z-2080
FGM-06X-2080
FGM-06Y-2080
FGM-06Z-2080
FGM-10Y-20
1/4 BSP.F
1/4 BSP.F
3/8 BSP.F
1/2 BSP.F
3/8 BSP.F
1/2 BSP.F
3/4 BSP.F
1 BSP.F
1 BSP.F
1-1/4 BSP.F
1-1/2 BSP.F
1-1/2, 2
FGM-01X-1090
FGM-02-2090
FGM-02X-2090
FGM-02Y-2090
FGM-03-2090
FGM-03X-2090
FGM-03Y-2090
FGM-03Z-2090
FGM-06X-2090
FGM-06Y-2090
FGM-06Z-2090
FGM-10Y-2090
1/4 NPT
1/4 NPT
3/8 NPT
1/2 NPT
3/8 NPT
1/2 NPT
3/4 NPT
1 NPT
1 NPT
1-1/4 NPT
1-1/2 NPT
1-1/2, 2
0.8 (1.8)
37 (81.6)
Thread
Size
Thread
Size
Sub-plate
Sub-plates are available. Specify the sub-plate model number from
the table above. When sub-plates are not used, the mounting surface
should have a good machined finish.
FGM-10Y is special type sub-plate to be used with pipe flange. When
ordering FGM-10Y, specify pipe flange kit in addition to FGM-10Y
referring to F3 pipe flange kits Catalogue (No. Pub. EC-3001).
Instructions
The minimum differential pressure between inlet and outlet port is required to obtain the optimum pressure com-
pensation. It varies according to the flow rate to be set. For details, please refer to the performance curves.
Min. required pressure difference
Check valve pressure drops vary with flow rates. If models with check valves are used, see free flow pressure drop
characteristics.
Free flow
Loosen the locking screw and turn the flow adjustment dial clockwise for increase, and anti-clockwise for decrease.
The dial makes about 4 revolutions from zero to full flow and the valve opening is indicated on the revolution indicator.
(Refer to characteristics of "Metred Flow vs. Dial Position").
After flow adjustments, tighten the locking screw.
Flow adjustment
[F
G-01]
Loosen the locking screw and turn the flow adjustment handle clockwise for increase, and anti-clockwise for decrease.
Open condition is indicated in digital-scale in built-in revolution indicator (Refer to the characteristics of "Metred
Flow vs. Dial Position").
After flow adjustments, tighten the locking screw.
[F
G-02, 03, 06, 10]
To carry out flow adjustments by as small degree as 2 L/min (.53 U.S.GPM) or less, be sure to use a line filter of
10
P
m or finer and install it near the valve inlet.
Line filter
Flow Control (and Check) Valves
-01/02/03/06/10
FG
FCG
No.3