DIRECTIONAL
CONTROLS
Options / Hydraulic Fluids / Instructions
Water containing fluids
Synthetic fluids
Petroleum base oils
Use water-glycol fluids or W/O emulsion fluids.
Use phosphate ester or polyol ester fluid.When phosphate ester fluid is used,
prefix "F-" to the model number because the special seals (fluororubber) are required to be used.
Use fluids equivalent to ISO VG32 or VG46.
0
50
120
150
1
2
3
4
0
0 100 200 300 400 500
0
10
20
30
MPa
PSI
1bf.
Tank Line Back Pressure
N
Operating
Force
SOL b
Plug-in Connector
with Solenoid
Indicator Light
Lock Nut
Push Button
SOL aSOL b
L'
L
No.4
Fluid Types
Hydraulic Fluids
Any type of hydraulic fluid, listed in the table below can be used.
Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.
Always be sure to use hydraulic fluids within the stipulated conditions shown below:
2
Viscosity: 15 to 400 mm /s (77 to 1800 SSU), Temperature: -15 to +70
°
C (5 to 160
°
F)
Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead
to breakdowns and shorten the life of the valve. Please maintain the degree of contamination within NAS 1638-Grade
12. Use 25
μ
m or finer line filter.
Control of Contamination
Recommended Viscosity and Oil Temperatures
Solenoid Operated Directional Valves
DSG-03/S-DSG-03
Push Button with Lock Nut
Options
Can be used for manual changeover of spool. The push button
can be locked in the pressed condition.
Plug-in Connector with Solenoid Indicator Light
These are the indicator light incorporated plug-in connector type
solenoids. Energisation or de-energisation of the solenoid can
be easily identified with the incorporated indicator light.
Mounting Posture
Instructions
In case No-spring detent type valves are used in the solenoid
de-energised state, install the valve in such a way that the axis
L-L' becomes horizontal to get the detent effect firmly. For the
valve types other than the above, there are no restrictions on
the mounting posture.
Solenoid Energisation
For double solenoid valves do not energise both at the same
time as it will result in coils burning out.
Valve Tank Port
Avoid connecting the valve tank port to a line with possible
surge pressure.
Piping end of tank line should be submerged in oil.
Shockless Type
In order to benefit from a shockless operation, it is necessary
to fill the tank line with operating oil.
Only after the tank line has been filled with operating oil, start
the operation of the valve on a regular basis.
Operating Force for Manual Override Push Pin
Please note that as the back pressure of the tank line rises, the
manual override push pin turns hard to operate (see the graph
below).
(Example)
Valve: DSG-03-3C2-A100-5002
Sub-plate: DSGM-03-4002
The valve is supplied with 4 pcs. hexagon
socket head cap screws M8
×
38 Lg.
M8 Mounting Bolts.
As the mounting bolts, M6 socket head cap screws are used for
the standard valves, however, M8 socket head cap screws are also
available for supply as optional extras. In case the M8 screws are
required, suffix "02" to the design number of both valve and sub-
plate model number like below.